PART NO. 37-6658D

Replaces 37-6658C

0927

36H UNIVERSAL GAS VALVES

FIELD

CONVERSION INSTRUCTIONS

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL
INJURY AND/OR PROPERTY DAMAGE.

White-Rodgers is a division

of Emerson Electric Co.

www.white-rodgers.com

DESCRIPTION

The 36H universal gas valves are designed for use on automatic

spark ignition systems. The valves are shipped from the factory

set for natural gas non-piloted applications. See the Installation

Instructions included with the valves for proper installation.

This document shows the modifications required if the valve is

to be installed on an LP gas and/or piloted gas application.

LP GAS CONVERSION

For LP gas conversion, use the LP conversion kit supplied

separately with this control. Refer to the instructions packed

separately with LP conversion kit.

PILOTED GAS APPLICATIONS

WIRING

These valves are shipped with an external wire jumper installed

for non-piloted gas applications. For applications requiring piloted

gas, such as intermittent pilot or spark-to-pilot systems, remove

the external wire jumper from the main (M) and pilot (P) valve

terminals (see figure 1).

Refer to the 36H Series Installation Instructions for additional

system wiring information.

PILOT GAS CONNECTION

These gas valves are shipped with the pilot outlet plugged. For

installations requiring pilot gas, remove the plug from the pilot

gas outlet (see figure 2) and use the fitting packed separately

with the valve.
Install the fitting into the pilot gas outlet, turning until finger tight.

Insert clean, de-burred ¼” O.D. tubing all the way through the

fitting. While holding the tubing securely, slowly tighten the fit-

ting until you feel a slight “give”. Tighten the fitting an additional

1-1/2 turns.
The plug should not be removed for a Direct Burner Ignition

system such as Direct Spark or Hot Surface Ignition.
Refer to the 36H Series Installation Instructions for pilot flame

adjustment information.

Pilot Gas

Outlet

Outlet

Pressure

Tap

Main Gas

Outlet

Figure 2. Gas valve outlet end

Model

No.

Opening

No.

of Stages

Characteristics

36H32-XXX

1

Fast

36H33-XXX

1

Slow

36H64-XXX

2

Fast

36H65-XXX

2

Slow

PILOT (REDUNDANT)

EXTERNAL

JUMPER

2ND

STAGE

TWO STAGE

MODELS ONLY

(+)

(-)

SW1

SW1

SW2

P

MAIN

C

SW2

RECTIFIER

(-)

RECTIFIER

(+)

M

RECTIFIER

(-)

(+)

HI

Figure 1. Gas valve internal wiring and terminal

identification

The Emerson logo is a
trademark and a service mark
of Emerson Electric Co.