White Rodgers 37-1896C - Manual
White Rodgers 37-1896C – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – INSTALLATION; WIRING; If none is offered, this diagram shows a suggested circuit.; SETTING THE CONTROL; CAUTION
- Page 3 – à ouverture sur hausse.; Charges du commutateur :; Fixé à 8; ATTENTION
- Page 4 – ANTICIPATION; constante, ne doit pas être inférieure à 135; CÂBLAGE; COMMANDES À BUTÉES RÉGLABLES; fabricant de l’équipement.; qui régissent les installations électriques.
WHITE-RODGERS DIVISION
EMERSON ELECTRIC CO.
9797 REAVIS RD., ST. LOUIS, MO. 63123
(314) 577-1300, FAX (314) 577-1517
9999 HWY. 48, MARKHAM, ONT. L3P 3J3
(905) 475-4653, FAX (905) 475-4625
Printed in U.S.A.
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
DESCRIPTION
INSTALLATION INSTRUCTIONS
INDUSTRIAL
TEMPERATURE CONTROL
ELECTRICAL DATA
Switch Action:
S.P.S.T. – Open on Rise
Switch Rating:
25A. 120V.A.C., 20A. 240V.A.C. NON-IND.
2.9A., 25V.A.C., 120V.A.C.
125V, PILOT DUTY 600V.A.C.
THERMAL DATA
Range:
100
°
to 500
°
F (38
°
to 260
°
C)
Differential: 15
°
F (8
°
C) Fixed
Capillary Length: 6 Ft. (1.8 m)
Bulb Size:
3/16" x 9-7/8"
SPECIFICATIONS
PRECAUTIONS
WARNING
THESE CONTROLS MUST BE INSTALLED BY A
QUALIFIED INSTALLER.
Do not exceed the specification ratings.
All wiring must conform to local and national electrical
codes and ordinances.
This control is a precision instrument, and should be
handled carefully. Rough handling or distorting compo-
nents could cause the control to malfunction.
This control has been accurately calibrated at the factory.
Any attempt to calibrate this control will void the White-
Rodgers warranty.
To prevent electrical shock and/or equipment
damage, disconnect electric power to system at
main fuse or circuit breaker box until installation
is complete.
Do not use on circuits exceeding specified volt-
ages. Higher voltages will damage control and
could cause shock or fire hazard.
CAUTION
WHITE-RODGERS
White-Rodgers Industrial Temperature Controls are suit-
able for most high temperature applications.
On small electric ovens, these controls may be used to
operate ovens directly. On ovens requiring a current
greater than the capacity of the control, these controls
may be used for controlling the pilot circuits of operating
relays.
These controls may also be used for controlling electri-
cally operated gas valves on gas fired equipment.
Operator: Save these instructions for future use!
PART NO. 37-1896C
Replaces 37-1896B & 37-9103
9548
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 CONTROLS WITH A FIXED DIFFERENTIAL The indicator (B) points to the temperature at which the contactsopen. To set the control: Use a screwdriver in the adjusting slot (A) on the front of thecontrol to rotate dial until the desired temperature at whichthe contacts will open is positioned directly un...
Imprimé aux É.-U.A. DESCRIPTION FICHE ÉLECTRIQUECommutation : Unipolaire unidirectionnelle (SPST) à ouverture sur hausse. Charges du commutateur : 25 A, 120 V C.A.; 20 A, 240 V C.A.; NON-IND.;2,9 A, 25 V C.A., 120 V C.A.;125 V, CHARGE DE VEILLEUSE 600 V C.A. SI VOUS NE LISEZ PAS ATTENTIVEMENT CES IN...
2 INSTALLATION L’anticipation est un facteur qui sert à diminuer le différentielnormal d’un régulateur. Pour assurer une forme d’anti-cipation, le capteur des régulateurs de température indus-triels peut être placé près de la source de chaleur. Ceciassure que le capteur détectera le chaleur avant qu...