WHITE-RODGERS

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY
AND/OR PROPERTY DAMAGE.

Model No.

Voltage

36C21U

36C21

36C21A

Current

D.C.

.23 Amp

.035 Amp

750 MV
24 volts

120 volts

WHITE-RODGERS DIVISION
EMERSON ELECTRIC CO.
9797 REAVIS ROAD
ST. LOUIS, MISSOURI 63123-5398

Printed in U.S.A.

PART NO. 37-4048B

Replaces 37-4048, 37-2570, 37-1972

9615

36C21 Series

Main Gas Valves

INSTALLATION INSTRUCTIONS

Operator: Save these instructions for future use!

These Gas Valves control the flow of gas to the main
burner under command of a room thermostat. They are
suitable for use on all gases and may be used with all
types of gas heating equipment. They may be mounted in
any position except upside down.

Some parts of this gas valve are also used to make more
complex combination gas controls. Disregard the nota-
tions “Pilot”, “Pilot Adj.” and “Vent ”. Although these
notations do appear on the valve, they are not functional
on model 36C21 Series controls.

DESCRIPTION

NOTE

SPECIFICATIONS

Electrical Rating:

Main Valve

Maximum Pressure Rating:

14" W.C. (

1

2

lb. per sq. in.)

Ambient Temperature: -40

°

to 175

°

F

Do not use this valve on indoor LP gas furnaces
except with 100% shut-off system.

Mounting: Any position except upside-down

CAUTION

!

PIPE SIZES/CAPACITIES

Pipe Size

(inches)

Capacity (BTU/hr) at

1” pressure drop across valve

1

2

” x

3

8

1

2

” x

1

2

1

2

” x

3

4

3

4

” x

3

4

100,000
230,000
230,000
280,000

162,000
372,600
372,600
453,600

Nat. Gas

(1000 BTU/cu. ft.,

64 Sp. Gr.)

LP Gas

(2500 BTU/cu. ft.,

1.53 Sp. Gr.)

MOUNTING POSITIONS:

Upright, 90

°

from upright or vertical

INLET BOSS
UP OR DOWN

UPRIGHT

LEFT OR RIGHT

360

°

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - PRECAUTIONS; WARNING; CAUTION

2 DO NOT BEGIN INSTALLATION UNTIL YOU READTHE FOLLOWING PRECAUTIONS. PRECAUTIONS 1. Failure to turn off electric or main gas supplyto heating system could cause personal in-jury and/or property damage by shock, gassuffocation, fire, and/or explosion. 2. Do not use this control on circuits exceedings...

Page 3 - NOTE

3 SYSTEM WIRING To prevent electrical shock and/or equipmentdamage, disconnect electrical power to system atmain fuse or circuit breaker box until installationis complete. All wiring should be installed in accordance with localand national electrical codes and ordinances. Always check that the elect...

Page 4 - PILOT GAS ADJUSTMENT; To REDUCE pilot pressure, turn the pilot adjust screw; ADJUSTMENT; PILOT LIGHTING

PILOT GAS ADJUSTMENT If the pilot flame is low and does not engulf the bulb of themercury flame sensor, the system will not energize themain valve. If pilot gas pressure is too high, gas will sputterpast the ignition electrode, and may not ignite. High pilotgas pressure may also cause the flame to l...

Other White Rodgers Models

All White Rodgers Other