White Rodgers 36C01 - Manual
White Rodgers 36C01 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – PRECAUTIONS; CAUTION; WARNING
- Page 3 – INSTALLATION; Pilot gas; Figure 2. Gas valve side view; MAIN PIPING CONNECTIONS; Figure 1. Typical gas valve piping
- Page 4 – Energize valve to ignite main burner.; NOTE; Figure 5. Pilot gas adjustment
- Page 5 – PILOT LIGHTING INSTRUCTIONS; Figure 7. Gas cock knob; TO TURN OFF GAS TO APPLIANCE
Electrical Rating:
24 VAC, 60 Hz., 23A
Pilot Gas Outlet:
Located at outlet end of the valve
Type of Gas:
Suitable for all domestic heating gases
Pressure Regulator Setting:
Adjustable from 2
1
⁄
2
to 5” W.C. (Factory adjusted
for 3.5” W.C.
Pressure Rating:
1
⁄
2
lb. per sq. in.
Ambient Temperature: -40
°
to 175
°
F
Mounting: Any position except upside-down
CAPACITY (IN BTU PER HOUR)
1
⁄
2
” x
3
⁄
8
”
1
⁄
2
” x
1
⁄
2
”
1
⁄
2
” x
3
⁄
4
”
3
⁄
4
” x
3
⁄
4
”
162,000
372,600
372,600
453,600
100,000
230,000
230,000
280,000
NATURAL GAS
(1000 Btu/Cu. Ft.
0.64 Sp. Gr.)
LP GAS
(2500 Btu/Cu. Ft.
1.53 Sp. Gr.)
INLET BOSS
UP OR DOWN
UPRIGHT
LEFT OR RIGHT
Upright, 90
°
from upright or vertical
NOTE: Control shown may not be identical to replacement control.
ON
OFF
WHITE-RODGERS DIVISION
EMERSON ELECTRIC CO.
9797 REAVIS ROAD
ST. LOUIS, MISSOURI 63123-5398
Printed in U.S.A.
PART NO. 37-5870B
Replaces 37-5870A
9947
INSTALLATION INSTRUCTIONS
WHITE-RODGERS
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY
AND/OR PROPERTY DAMAGE.
This multi-function gas controls combines into a single
compact package the functions of 3-position gas cock, a
main gas valve and a pressure regulator. The pilot outlet
is plugged, but will accept a
1
⁄
4
” pilot line connection. This
control can be mounted in any orientation except upside
down.
To permit replacement of a variety of valve sizes, this
control is furnished with three reducer bushings (two
3
⁄
4
” to
1
⁄
2
” and one
1
⁄
2
” to
3
⁄
8
”). Also included is a conversion kit
which allows this valve to be used at regulator settings of
4.2” W.C. to 11.0” W.C.
Operator: Save these instructions for future use!
DESCRIPTION
SPECIFICATIONS
36C01
Combination Gas Valves
(24 Volt and 120 Volt Models)
OFF
PILOT
ON
MODELS AVAILABLE
Model No.
Voltage
36C01
36C01A
Current
.23 Amp
.035 Amp
24 volts
120 volts
Gas
Nat.
Nat.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 PRECAUTIONS DO NOT BEGIN INSTALLATION UNTIL YOU READTHE FOLLOWING PRECAUTIONS. CAUTION ! WARNING ! If you do not follow these instructions exactly, a fire or explosion may result, causing property damage, personal injury or loss of life. 1. Failure to turn off electric or main gas supplyto heating...
3 INSTALLATION Pilot gas outlet Gas outlet PILOT PRESS TAP Figure 2. Gas valve side view MAIN PIPING CONNECTIONS All piping must comply with local codes, ordinances,and/or national fuel gas codes. 1. Turn off electrical power to the system at the fuse boxor circuit breaker. Also turn off the main ga...
4 INSTALLATION (cont’d) SYSTEM WIRING To prevent electrical shock and/or equipmentdamage, disconnect electrical power to system atmain fuse or circuit breaker box until installationis complete. All wiring should be installed in accordance with localand national electrical codes and ordinances. Alway...