FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
DESCRIPTION
INSTALLATION INSTRUCTIONS
259-6
TEMPERATURE CONTROL
Barn Ventilating
Two Speed Fan Control
SPECIFICATIONS
ELECTRICAL DATA
Switch Action: Left Selector – Close on Rise
Right Selector – S.P.D.T.
Switch Rating:
7.4F.L.A. 44.5L.R.A., 120V.A.C.
3.7F.L.A. 22.2L.R.A., 240V.A.C.
2.9 Amp., 120/240V.A.C.
THERMAL DATA
Range: High Limit - 35
°
to 110
°
F (2
°
to 43
°
C)
Differential: Left Selector - 3
°
F (1.7
°
C) Fixed
Right Selector - 4
°
F (2.2
°
C) Fixed
CAUTION
To prevent electrical shock and/or equipment
damage, disconnect electric power to system at
main fuse or circuit breaker box until installation
is complete.
WARNING
Do not use on circuits exceeding specified voltages.
Higher voltages will damage control and could cause
shock or fire hazard.
THESE CONTROLS MUST BE INSTALLED BY A
QUALIFIED INSTALLER
Do not exceed the specification ratings.
All wiring must conform to local and national electrical
codes and ordinances.
This control is a precision instrument, and should be
handled carefully. Rough handling or distorting compo-
nents could cause the control to malfunction.
This control has been accurately calibrated at the factory.
Any attempt to calibrate this control will void the White-
Rodgers warranty.
PRECAUTIONS
WHITE-RODGERS
Operator: Save these instructions for future use!
PART NO. 37-5567A
Replaces 37-9187
9547
This Hydraulic-Action temperature control is specifically
designed to control the operation of fans in reducing
temperature and humidity in such places as:
Stock Barns
Dairy Barns
Hog Houses
Poultry Houses
It has a moisture, vermin and dust resistant enclosure,
with the coiled bulb below to prevent collection of foreign
matter from impairing sensitivity.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 PRINCIPLE OF OPERATION When the temperature in the controlled area rises, thefluid in the coiled bulb expands, causing the contacts inthe switch mechanism to snap closed, turning on theventilating fan to high speed. As the area cools, the fluid contracts. When the tempera-ture reaches the control ...
INSTRUCTIONS D’INSTALLATION 259-6 RÉGULATEUR DE TEMPÉRATURE Commande à deux vitesses pour ventilateur d’étable Utilisateur: conservez ces instructions pour vous y référer au besoin! SI VOUS NE LISEZ PAS ATTENTIVEMENT CES INSTRUCTIONS AVANTD’INSTALLER ET D’UTILISER LA COMMANDE, VOUS RISQUEZ DE CAUSER...
2 PRINCIPE DE FONCTIONNEMENT ÉTAPE 1 : Régler le sélecteur de basse vitesse à la température à laquelle il est souhaité quel’interrupteur de gauche fasse fonctionner leventilateur à basse vitesse. Si le différentielest réglé au minimum, le ventilateur seraarrêté lorsque la température sera environ à...