WHITE-RODGERS DIVISION
EMERSON ELECTRIC CO.
9797 REAVIS RD., ST. LOUIS, MO. 63123
(314) 577-1300, FAX (314) 577-1517

9999 HWY. 48, MARKHAM, ONT. L3P 3J3
(905) 475-4653, FAX (905) 475-4625

Printed in U.S.A.

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.

DESCRIPTION

INSTALLATION INSTRUCTIONS

259-6

TEMPERATURE CONTROL

Barn Ventilating

Two Speed Fan Control

SPECIFICATIONS

ELECTRICAL DATA

Switch Action: Left Selector – Close on Rise

Right Selector – S.P.D.T.

Switch Rating:

7.4F.L.A. 44.5L.R.A., 120V.A.C.
3.7F.L.A. 22.2L.R.A., 240V.A.C.
2.9 Amp., 120/240V.A.C.

THERMAL DATA

Range: High Limit - 35

°

to 110

°

F (2

°

to 43

°

C)

Differential: Left Selector - 3

°

F (1.7

°

C) Fixed

Right Selector - 4

°

F (2.2

°

C) Fixed

CAUTION

To prevent electrical shock and/or equipment
damage, disconnect electric power to system at
main fuse or circuit breaker box until installation
is complete.

WARNING

Do not use on circuits exceeding specified voltages.
Higher voltages will damage control and could cause
shock or fire hazard.

THESE CONTROLS MUST BE INSTALLED BY A
QUALIFIED INSTALLER

Do not exceed the specification ratings.

All wiring must conform to local and national electrical
codes and ordinances.

This control is a precision instrument, and should be
handled carefully. Rough handling or distorting compo-
nents could cause the control to malfunction.

This control has been accurately calibrated at the factory.
Any attempt to calibrate this control will void the White-
Rodgers warranty.

PRECAUTIONS

WHITE-RODGERS

Operator: Save these instructions for future use!

PART NO. 37-5567A

Replaces 37-9187

9547

This Hydraulic-Action temperature control is specifically
designed to control the operation of fans in reducing
temperature and humidity in such places as:

Stock Barns

Dairy Barns

Hog Houses

Poultry Houses

It has a moisture, vermin and dust resistant enclosure,
with the coiled bulb below to prevent collection of foreign
matter from impairing sensitivity.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - CAUTION; WIRING

2 PRINCIPLE OF OPERATION When the temperature in the controlled area rises, thefluid in the coiled bulb expands, causing the contacts inthe switch mechanism to snap closed, turning on theventilating fan to high speed. As the area cools, the fluid contracts. When the tempera-ture reaches the control ...

Page 3 - INSTRUCTIONS D’INSTALLATION; RÉGULATEUR DE TEMPÉRATURE; DESCRIPTION; ATTENTION; SPÉCIFICATIONS

INSTRUCTIONS D’INSTALLATION 259-6 RÉGULATEUR DE TEMPÉRATURE Commande à deux vitesses pour ventilateur d’étable Utilisateur: conservez ces instructions pour vous y référer au besoin! SI VOUS NE LISEZ PAS ATTENTIVEMENT CES INSTRUCTIONS AVANTD’INSTALLER ET D’UTILISER LA COMMANDE, VOUS RISQUEZ DE CAUSER...

Page 4 - CÂBLAGE

2 PRINCIPE DE FONCTIONNEMENT ÉTAPE 1 : Régler le sélecteur de basse vitesse à la température à laquelle il est souhaité quel’interrupteur de gauche fasse fonctionner leventilateur à basse vitesse. Si le différentielest réglé au minimum, le ventilateur seraarrêté lorsque la température sera environ à...

Other White Rodgers Models

All White Rodgers Other