Table of Contents:

  • Page 2 – SPECIFICATIONS; ELECTRICAL DATA; SELECT THERMOSTAT LOCATION; THERMAL DATA; INSTALLATION; CAUTION
  • Page 3 – With wallplate still attached to humidity control and; WIRING; Figure 4. Typical Furnace Humidifier Humidistat Wiring Diagram
  • Page 4 – OPERATION; Figure 5. Typical Parallel Wiring Diagram of Dehumidistat with; An operational check can be made as follows:; Low Voltage Digital Thermostat
  • Page 5 – DEHUMIDISTAT CONTROL
  • Page 6 – TABLE DES MATIÈRES; DESCRIPTION; Ne dépassez pas les charges nominales.; PRÉCAUTIONS; Humidostat à basse tension; INSTRUCTIONS D'INSTALLATION; AVERTISSEMENT
  • Page 7 – SPÈCIFICATIONS; FICHE ÉLECTRIQUE; CHOIX D'UN SITE POUR LE THERMOSTAT; FICHE THERMIQUE; Figure 1. Acheminement du câblage au site; ATTENTION
  • Page 8 – CÂBLAGE; Figure 4. Schéma de câblage typique de l'humidostat pour un
  • Page 9 – COMMANDE D'HUMIDIFICATION; Figure 5. Schéma typique de câblage de la commande de; La vérification du fonctionnement peut être exécutée
  • Page 10 – COMMANDE DE DÉSHUMIDIFICATION; RÉGLAGE
Loading the manual

CONTENTS

Description .............................................................................. 1
Precautions ............................................................................. 1
Specifications .......................................................................... 2
Installation ............................................................................... 2

Select Humidity Control Location
Route Wires to Location
Wiring
Attach Humidity Control to Wall

Operation ................................................................................ 4

Humidistat Control
Dehumidistat Control

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.

DESCRIPTION

These wall-mounted, line or low voltage humidity controls
are available as a Humidistat commonly used to control
and operate a furnace humidifier or as a Dehumidistat
commonly used to cycle an air conditioning system to
control humidity in an unoccupied home to prevent mil-
dew build-up associated with high humidity levels.

These humidity controls feature a moisture-sensitive
nylon sensing element and also provide positive ON-OFF
settings for manual operation.

Operator: Save these instructions for future use!

If in doubt about whether your wiring is line, or low voltage,
have it inspected by a qualified heating and air condition-
ing contractor, electrician, or someone familiar with basic
electricity and wiring.

Do not exceed the specification ratings.

All wiring must conform to local and national electrical
codes and ordinances.

PRECAUTIONS

This control is a precision instrument, and should be
handled carefully. Rough handling or distorting compo-
nents could cause the control to malfunction.

To prevent electrical shock and/or equipment dam-
age, disconnect electric power to system, at main
fuse or circuit breaker box, until installation is
complete.

Do not short out terminals on primary control to
test. Short or incorrect wiring will burn out humid-
ity control and could cause personal injury and/or
property damage.

2271W

2274W

CAUTION

Do not use on circuits exceeding the rated volt-
age. Higher voltage will damage control and could
cause shock or fire hazard.

WARNING

2271/72/73/74W

Line or Low Voltage

Humidistat / Dehumidistat

INSTALLATION INSTRUCTIONS

PART NO. 37-9600D

Replaces 37-9600C

0528

White-Rodgers is a division

of Emerson Electric Co.

www.white-rodgers.com

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - SPECIFICATIONS; ELECTRICAL DATA; SELECT THERMOSTAT LOCATION; THERMAL DATA; INSTALLATION; CAUTION

2 SPECIFICATIONS ELECTRICAL DATA Electrical Rating: 2271W Humidistat 0.5A, @ 120V AC, 60Hz. 2272W 2273W De-Humidistat 1.0A, @ 120V AC, 60 Hz. 2274W Pilot Duty 30V AC, 60Hz., 60VA. SELECT THERMOSTAT LOCATION Proper location insures that the humidity control willprovide a desired humidity level throug...

Page 3 - With wallplate still attached to humidity control and; WIRING; Figure 4. Typical Furnace Humidifier Humidistat Wiring Diagram

3 ATTACHING HUMIDITY CONTROL TO ELECTRICAL BOX 1. With wallplate still attached to humidity control and wires through wallplate, connect leads together; oneblack to Line, other black to Load and secure with wirenuts. Connect green wire to electrical box ground.(see Fig. 2) 2. Remove the two screws f...

Page 4 - OPERATION; Figure 5. Typical Parallel Wiring Diagram of Dehumidistat with; An operational check can be made as follows:; Low Voltage Digital Thermostat

4 Y G W RC RH HEAT COOL HEAT COOL RC RH W Y G ON OFF OFF AUTO THERMOSTAT SYSTEM FAN RELAY COOLING RELAY 24vAC 120vAC TRANSFORMER JUMPER WIRE HEATING SYSTEM WIRE NUTS TYPE 2273/2274 DEHUMIDISTAT DEHUMIDISTAT FIELD-WIRING TYPE 1F90(W) AUX. RELAY AUXILIARY RELAY CONTACTS S.P.S.T N.O. GREEN WIRE HUMIDIS...