White Rodgers 1F97-0671 - Manual

White Rodgers 1F97-0671

White Rodgers 1F97-0671 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
Page: / 12

Table of Contents:

  • Page 2 – OFF; Power Stealing Switches; WARNING; Rear view of thermostat
  • Page 3 – WIRING CONNECTIONS; TERMINAL DESIGNATION DESCRIPTIONS; WIRING DIAGRAMS; Single Stage Connections; SINGLE STAGE; Figure 3 – Single Stage System (No Heat Pump) with Two Transformers
  • Page 4 – Programming and Confi guration Items; indicates when heating or cooling stage; THERMOSTAT QUICK REFERENCE; Home Screen Description; Figure 5 – Home Screen Display; in Menu mode when selecting key-; Change
  • Page 5 – INSTALLER/CONFIGURATION MENU; to change a menu item options.
  • Page 8 – OPERATING YOUR THERMOSTAT; Fan Operation; NOTE; Check Thermostat Operation; Heating System; CAUTION; Cooling System
  • Page 9 – PROGRAMMING; Energy Saving Factory Pre-Program
  • Page 11 – Weighing of Remote Reading:
  • Page 12 – Reset Operation; and; TROUBLESHOOTING
Loading the manual

Blue Residential Ther mostat

with Automatic Heat/Cool

Changeover Option

Model

Programming Choices

1F97-0671

7 Day

5/1/1 Day

Non-Programmable

www.white-rodgers.com

PART NO. 37-6975A

0832

For Single Stage Applications

Installation and Operating Instructions for Model:

APPLICATIONS

THERMOSTAT APPLICATION GUIDE

1F97-0671 Residential Thermostat

SPECIFICATIONS

To prevent electrical shock and/or equipment damage,
disconnect electric power to system at main fuse or
circuit breaker box until installation is complete.

CAUTION

!

Save these instructions for future use!

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS
CAREFULLY BEFORE INSTALLING OR OPERATING THIS
CONTROL COULD CAUSE PERSONAL INJURY AND/OR
PROPERTY DAMAGE.

Description

Heat Pump (No Aux. or Emergency Heat)

Yes

Heat Only Systems

Yes

Millivolt Heat Only Systems – Floor or Wall Furnaces

Yes

Cool Only Systems

Yes

Gas or Oil Heat

Yes

Electric Furnace

Yes

Hydronic (Hot Water) Zone Heat – 2 Wires

Yes

Hydronic (Hot Water) Zone Heat – 3 Wires

Yes

Wired Remote Temperature Sensor (Indoor or Outdoor)

Yes

ATTENTION: MERCURY NOTICE

This product does not contain mercury. However, this prod-
uct may replace a product that contains mercury.

Mercury and products containing mercury must not be
discarded in household trash. Do not touch any spilled
mercury. Wearing non-absorbent gloves, clean up any
spilled mercury and place in a sealed container. For proper
disposal of a product containing mercury or a sealed
container of spilled mercury, place it in a suitable shipping
container. Refer to

www.white-rodgers.com

for location to

send product containing mercury.

Index

Page

Installation

2

Wiring Connections

3

Wiring Diagrams

3

Thermostat Quick Reference

4

Installer Confi guration Menu

5

Operating Your Thermostat

8

Programming

9

Troubleshooting

12

Electrical Rating:

Battery Power . . . . . . . . . . . . . . . . . . . . . . . . . . mV to 30 VAC, NEC Class II, 50/60 Hz or DC

Input-Hardwire . . . . . . . . . . . . . . . . . . . . . . . . . 20 to 30 VAC

Terminal Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.5A per terminal, 2.5A maximum all terminals combined
Setpoint Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 to 99°F (7 to 32°C)
Differential (Single Stage) . . . . . . . . . . . . . . . . . . . . Heat 0.6°F; Cool 1.2°F
Operating Ambient . . . . . . . . . . . . . . . . . . . . . . . . . . 32°F to +105°F (0 to +41°C)
Operating Humidity . . . . . . . . . . . . . . . . . . . . . . . . . 90% non-condensing max.
Shipping Temperature Range . . . . . . . . . . . . . . . . . -40 to +150°F (-40 to +65°C)
Dimensions Thermostat . . . . . . . . . . . . . . . . . . . . . . 4.2"H x 6.4"W x 1.7"D

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - OFF; Power Stealing Switches; WARNING; Rear view of thermostat

2 Remove Old Thermostat Before removing wires from old thermostat, mark wires for terminal identifi cation so the proper connections will be made to the new thermostat. Installing New Thermostat 1. Pull the thermostat body off the thermostat base. Forcing or prying on the thermostat will cause damag...

Page 3 - WIRING CONNECTIONS; TERMINAL DESIGNATION DESCRIPTIONS; WIRING DIAGRAMS; Single Stage Connections; SINGLE STAGE; Figure 3 – Single Stage System (No Heat Pump) with Two Transformers

3 Single Stage System RC RH C Y* W* G O/B 6 L CLASS II TRANSFORMER HOT 24VAC NEUTRAL 120VAC Call for heat 24 volt power for cooling 24 volt power for heating 24 volt common (optional for system operation, required for remote sensor and system status indicator) Call for cool Blower/Circulator fan ene...

Page 4 - Programming and Confi guration Items; indicates when heating or cooling stage; THERMOSTAT QUICK REFERENCE; Home Screen Description; Figure 5 – Home Screen Display; in Menu mode when selecting key-; Change

4 Programming and Confi guration Items 1 "System On" indicates when heating or cooling stage is energized. 2 The word "Hold" is displayed when the thermostat is in the Hold mode. "Temp" is displayed when the thermostat is in a Temporary HOLD mode. 3 Displays "Change Filte...

Other White Rodgers Models

All White Rodgers Other