White Rodgers 1F95W-80 - Manual

White Rodgers 1F95W-80

White Rodgers 1F95W-80 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
Page: / 8

Table of Contents:

  • Page 2 – SPECIFICATIONS; Operating Ambient Temperature Range:; INSTALLATION; SELECT THERMOSTAT LOCATION; Locate thermostat about 5 ft. above the floor.; ROUTE WIRES TO LOCATION; Probe for obstructions in partition before drilling; NOTE; Figure 1. Routing thermostat wires
  • Page 3 – TABLE 1. TERMINAL REFERENCE; REPLACEMENT INSTALLATION; REMOVE OLD THERMOSTAT; Move subbase out of the way. Drill mounting holes.
  • Page 4 – WARNING; Figure 4. Typical wiring diagram for single transformer systems; TABLE 2. WIRE IDENTIFICATION LABELS; CAUTION
  • Page 6 – ATTACH THERMOSTAT TO SUBBASE; USE; TO SET THERMOSTAT TO OFF BEFORE; OPERATION; SET OPTION SWITCHES; Figure 7. Attaching thermostat to subbase; Figure 8. Back of thermostat; Option switches
  • Page 7 – LOCKOUT BYPASS OPTION; CHECK THERMOSTAT OPERATION; FAN OPERATION; HEATING SYSTEM; COOLING SYSTEM; F, DO NOT operate the
Loading the manual

Printed in U.S.A.

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.

PART NO. 37-5522A

9529

DESCRIPTION

PRECAUTIONS

1F95W-80

7 Day Multi-stage Electronic Digital Thermostat

with Programmable Fan

INSTALLATION INSTRUCTIONS

WHITE-RODGERS

All wiring must conform to local and national electrical
codes and ordinances.

This control is a precision instrument, and should be
handled carefully. Rough handling or distorting compo-
nents could cause the control to malfunction.

To prevent electrical shock and/or equipment
damage, disconnect electric power to system at
main fuse or circuit breaker box until installation
is complete.

Do not use on circuits exceeding specified volt-
age. Higher voltage will damage control and could
cause shock or fire hazard.

Do not short out terminals on gas valve or primary
control to test. Short or incorrect wiring will burn
out thermostat and could cause personal injury
and/or property damage.

R

This wall-mounted, low voltage thermostat maintains
room temperature by controlling the operation of multi-
stage systems. Use this thermostat for applications re-
quiring up to two stages of heat and/or cool. Indicator
lights show the system status. The user will program two
time/temperature settings (occupied and unoccupied) per
24 hour period and may program each day independently.
The thermostat will store both heating and cooling pro-
grams simultaneously. A 9 volt Energizer

®

battery will

maintain the stored program for approximately one week,
if incoming power should fail. If power failure is extensive
and the program is lost, after power restoration, the
t h e r m o s t a t w i l l a u t o m a t i c a l l y m a i n t a i n a f a c t o r y
preprogrammed heating temperature of 64

°

F or a cooling

temperature of 82

°

F.

If in doubt about whether your wiring is millivolt, line, or low
voltage, have it inspected by a qualified heating and air
conditioning contractor, electrician, or someone familiar
with basic electricity and wiring.

Do not exceed the specification ratings.

WHITE-RODGERS DIVISION
EMERSON ELECTRIC CO.
9797 REAVIS ROAD
ST. LOUIS, MISSOURI 63123-5398

CONTENTS

Description ......................................................... 1
Precautions ........................................................ 1
Specifications ..................................................... 2
Installation .......................................................... 2

New Installation

Select Thermostat Location
Route Wires to Location

Replacement Installation

Remove Old Thermostat
Attach Subbase to Wall
Attach Thermostat to Subbase

Operation ........................................................... 6

System Configuration

Set Option Switches

Check Thermostat Operation

Fan Operation
Heating System
Cooling System

Additional Operation Notes
Troubleshooting

WARNING

!

CAUTION

!

Operator: Save these instructions for future use!

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - SPECIFICATIONS; Operating Ambient Temperature Range:; INSTALLATION; SELECT THERMOSTAT LOCATION; Locate thermostat about 5 ft. above the floor.; ROUTE WIRES TO LOCATION; Probe for obstructions in partition before drilling; NOTE; Figure 1. Routing thermostat wires

2 SPECIFICATIONS THIS CONTROL IS DESIGNED FOR USE WHERE BOTH SIDES OF THE TRANSFORMER ARE PRESENT TOTHE THERMOSTAT (both the hot and common sides of the 24 VAC end of the transformer.) ELECTRICAL DATAElectrical Rating: 20 to 30 VAC 50/60 Hz.0.01 to 1.5 Amps (Load per terminal)2.5 Amps Maximum Total ...

Page 3 - TABLE 1. TERMINAL REFERENCE; REPLACEMENT INSTALLATION; REMOVE OLD THERMOSTAT; Move subbase out of the way. Drill mounting holes.

3 TABLE 1. TERMINAL REFERENCE LABEL NUMBER 1F95 TERMINAL DESIGNATION FUNCTION OLD THERMOSTAT TERMINAL DESIGNATION (1)(2)(3)(4)(5)(6)(7)(8)(9) (10)(11)(12)(13) G C R O B Y1 Y2 W1W2 A1 Fan OutputTransformer 24 VAC Common Transformer 24 VAC HotChangeover Output (Cooling)Changeover Output (Heating) Stag...

Page 4 - WARNING; Figure 4. Typical wiring diagram for single transformer systems; TABLE 2. WIRE IDENTIFICATION LABELS; CAUTION

4 WARNING ! C R G B O CHANGEOVER ENERGIZED IN HEAT CHANGEOVER ENERGIZED IN COOL COMPRESSOR CONTACTOR STAGE 1 FAN RELAY HEAT RELAY STAGE 1 HEAT RELAY STAGE 2 DAMPER THERMOSTAT CONTROL CIRCUIT COMPRESSOR CONTACTOR STAGE 2 24 VAC 120 VAC HOT NEUTRAL THERMOSTAT SYSTEM Y1 Y2 W1 W2 A1 Figure 4. Typical wi...