White Rodgers 1F95CA-391 - Manual
White Rodgers 1F95CA-391 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – REMOVE OLD THERMOSTAT; Figure 1. Thermostat base and terminals; INSTALLATION; ATTACH BASE TO WALL; ” pilot holes, and install screw anchors in; Mounting screws
- Page 4 – RESET SWITCH; Figure 2. Switch locations on back of thermostat body; CONFIGURATION; SWITCHES; Figure 4. Typical Wiring for 120V Humidifier System; If you have a single stage compressor system see the diagram below.; Reset switch
- Page 5 – INSTALLER CONFIGURATION
- Page 6 – INSTALLER TABLE; at same time and release to enter the Configuration Menu.; Returns to Normal Operation.; Step; and
- Page 7 – To turn this feature OFF, press; Lockout Bypass Option; and SET; buttons at the same time.; HEATING; Shorter
- Page 8 – setting an item to ON, you can then use; or; to exit the menu and return to; SERVICE REMINDER; Set Humidifier Maintenance Reminder.; Service Button Menu
- Page 9 – CHECK THERMOSTAT OPERATION; FAN OPERATION; until FAN ON is displayed.; HEATING SYSTEM; to lower temperature; CAUTION
- Page 10 – No Heat; RESET BUTTON; To reset the thermostat, press and release; PROGRAM; HOLD; mode and will; Symptom; Thermostat Does Not Follow Program; TROUBLESHOOTING
- Page 12 – FAQs; What is the thermostat Click Test?
WHITE-RODGERS 90 SERIES
1F95CA-391
MULTI-STAGE/HEAT PUMP INSTALLATION/CONFIGURATION
This White-Rodgers Digital Thermostat uses
microcomputer technology to provide precise
time, humidity, and temperature control. This
thermostat offers the flexibility to design
1F95CA-391: 7 Day programming;
residential applications.
ELECTRICAL DATA
Electrical Rating:
20 to 30 VAC, 50/60 Hz with common
0.05 to 1.5 Amps per terminal
2.5 Amps maximum total load (all
terminals combined).
Hardwired only.
C terminal is required.
INSTALLATION
Part No. 37-6583A
0504
DESCRIPTION
SPECIFICATIONS
heating and cooling programs that fit
building needs. This thermostat is adaptable
to most 24 volt residential forced air multi-
Standard Systems:
Multi-stage gas, oil, electric.
Single-stage or two-stage compressor
heat pump.
THERMAL DATA
Setpoint Temperature Range:
45° to 99°F (7° to 37°C)
Operating Ambient Temperature:
32° to 110°F (0° to 43°C)
Operating Humidity Range:
90% non-condensing max.
Shipping Temperature Range:
-4° to 149°F (-20° to 65°C)
PRECAUTIONS
Do not short out terminals on gas valve
or primary control to test. Short or
incorrect wiring will damage thermostat
and could cause personal injury and/or
property damage.
Do not use on circuits exceeding
specified voltage. Higher voltage will
damage thermostat and could cause
shock or fire hazard.
Thermostat installation and all compo-
nents of the system shall conform to
Class II circuits per the NEC code.
To prevent electrical shock and/or
equipment damage, disconnect electric
power to system at main fuse or circuit
breaker box until installation is
complete.
Read all instructions thoroughly before
beginning installation.
This thermostat is intended for use with a
low voltage system. Do not use on a line
voltage system.
CAUTION
!
WARNING
!
Do not exceed ratings shown in the Specifi-
cations section, above. If in doubt about the
electrical ratings of your heating/cooling
system, have it inspected by a qualified
heating and air conditioning contractor or
licensed electrician.
All wiring must conform to local and
national electrical codes and ordinances.
This control is a precision instrument, and
should be handled carefully. Rough handling
or distorting components could cause the
control to malfunction.
NOTE
stage or heat pump systems with electric or
fossil fuel auxiliary.
White-Rodgers is a division
of Emerson Electric Co.
www.white-rodgers.com
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
ATTENTION! This product does not contain mercury.However, this product may replace a unitwhich contains mercury. Do not open mercury cells. If a cell becomesdamaged, do not touch any spilled mercury.Wearing non-absorbent gloves, take up thespilled mercury with sand or other absorbentmaterial and pla...
RESET SWITCH See the Troubleshooting section at the endof this document for more information aboutthe function of this switch. E2/P SWITCH (DHM) TERMINALFUNCTION The E2/P switch is located on the back ofthe thermostat body (see fig. 2). This switchcontrols how the DHM terminal will beenergized. 1. I...
INSTALLER CONFIGURATION BEFORE TURNING POWER ON, pleaseread the following instructions. Beforeoperating the system, you must configurethe thermostat to operate properly withyour equipment. The thermostat, as it comes from the factory,is configured to operate a standard multi-stage electric forced ho...