White Rodgers 1F87-251 - Manual
White Rodgers 1F87-251 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – INSTALLATION; REMOVE OLD THERMOSTAT; the labels enclosed with the new thermostat.; ELECTRIC HEAT OR SINGLE-STAGE; ATTACH THERMOSTAT BASE TO WALL; BATTERY LOCATION; CHECK THERMOSTAT OPERATION; Fan Operation; Figure 1. Thermostat Base
- Page 3 – Figure 7. Typical wiring diagram for heat pump; Heating System; CAUTION; Cooling System
- Page 4 – The Thermostat Buttons and Switches; CONFIGURATION MENU; OPERATION
- Page 5 – OPERATING FEATURES; Step; Configuration Menu
- Page 6 – PROGRAMMING YOUR THERMOSTAT; Planning Your Program; Set Current Time and Day; Enter Heating Program; COOL
- Page 7 – NOTE; Enter Cooling Program; CHECK YOUR PROGRAMMING; TROUBLESHOOTING
Do not use on circuits exceeding specified voltage.
Higher voltage will damage control and could cause
shock or fire hazard.
Do not short out terminals on gas valve or primary
control to test. Short or incorrect wiring will damage
thermostat and could cause personal injury and/or
property damage.
Thermostat installation and all components of the
system shall conform to Class II (current limited) cir-
cuits per the NEC code. Failure to do so may cause a
fire hazard.
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
DESCRIPTION
Your new White-Rodgers 7-Day Digital Thermostat uses the
technology of a solid-state microcomputer to provide precise
time/temperature control. This thermostat offers you the flexibil-
ity to design heating and cooling programs that fit your needs.
Features:
• Separate program for each day of the week with four separate
time/temperature settings per day
• Simultaneous heat and cool program storage
• Preprogrammed temperature control
• LCD continuously displays setpoint, and alternately dis-
plays time and room temperature
• Backlit display
• Temperature override until next program period
• Manual program override (HOLD temperature)
• °F/°C convertibility
• Temperature range 45° to 90°F
• RC, RH, W, Y, G , O and B terminals
• B and O terminals for single stage heat pumps (no auxiliary
heat) or damper operation
• Program storage in case of power loss.
• Battery powered (2 "AA" Energizer
®
alkaline batteries in-
cluded)
SPECIFICATIONS
ELECTRICAL DATA
Electrical Rating:
8 to 30 VAC 50/60 Hz. or D.C.
0.05 to 1.0 Amps (Load per terminal)
1.5 Amps Maximum Total Load (All terminals combined)
THERMAL DATA
Setpoint Temperature Range:
45°F to 90°F (7°C to 32°C)
Operating Ambient Temperature Range:
32°F to 105°F
Operating Humidity Range:
0 to 90% RH (non-condensing)
Shipping Temperature Range:
-4°F to 150°F
APPLICATIONS
For use with:
•
Standard heat/cool or heat only systems
•
Electric heat systems
•
Gas or oil fired systems
•
Gas systems with intermittent ignition devices (I.I.D.)
and/or vent dampers
•
Hydronic (hot water or steam) systems
•
Single-stage heat pump systems (no auxiliary heat)
•
Millivolt systems
DO NOT USE WITH:
•
Multi-stage systems
•
Systems exceeding 30 VAC and 1.5 amps
•
3-wire zoned hydronic heating systems
1F87-251
Programmable Electronic Digital Thermostat
PART NO. 37-6417C
Replaces 37-6417B
0441
WHITE-RODGERS
EMERSON ELECTRIC CO.
9797 REAVIS ROAD
ST. LOUIS, MISSOURI 63123-5398
www.white-rodgers.com
INSTALLATION AND
OPERATION INSTRUCTIONS
PRECAUTIONS
CAUTION
!
This thermostat is intended for use with a low voltage system;
do not use this thermostat with a line voltage system. If in doubt
about whether your wiring is millivolt, line, or low voltage, have
it inspected by a qualified heating and air conditioning contractor
or electrician.
Do not exceed the specification ratings.
All wiring must conform to local and national electrical codes and
ordinances.
This control is a precision instrument, and should be handled
carefully. Rough handling or distorting components could cause
the control to malfunction.
To prevent electrical shock and/or equipment dam-
age, disconnect electric power to system at main fuse
or circuit breaker box until installation is complete.
WARNING
!
Operator: Save these instructions for future use!
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 INSTALLATION REMOVE OLD THERMOSTAT 1. Shut off electricity at the main fuse box until installation is complete. Ensure that electrical power is disconnected. 2. Remove the front cover of the old thermostat. With wires still attached, remove wall plate from the wall. If the oldthermostat has a wall...
3 RH Y 24 VAC 120 VAC Hot Neutral THERMOSTAT SYSTEM G W Figure 5. Typical wiring diagram for heat/cool, 5-wire, two-transformer systems HEATING TRANSFORME R (Class II Current Limited) Heating System Fan Relay Cooling System RC 24 VAC 120 VAC Hot Neutral COOLING TRANSFORMER (Class II Current Limited)...
4 Press HOLD to change to the next menu item or press TIME togo backwards to the previous item in the menu. To exit the menuand return to the program operation, press RUN. If no keys arepressed within fifteen minutes, the thermostat will revert tonormal operation. 1) Select FA or SL (Fast or Slow) H...