White Rodgers 1F85ST-0422 - Manual

White Rodgers 1F85ST-0422

White Rodgers 1F85ST-0422 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
Page: / 8

Table of Contents:

  • Page 2 – INSTALLATION; WARNING; Remove Old Thermostat; WIRING CONNECTIONS
  • Page 3 – THERMOSTAT QUICK REFERENCE; Home Screen Description; indicates good power level; Cambiar
  • Page 4 – INSTALLER/CONFIGURATION MENU
  • Page 6 – Set Current Time and Date; Enter the Heating Program
  • Page 7 – PROGRAMMING (For Programmable Model Only); Planning Your Program – Important
  • Page 8 – TROUBLESHOOTING; Symptom
Loading the manual

1

Blue Selecto Ther mostat with

Automatic Heat/Cool Changeover Option

Single Stage, Multi-Stage or Heat Pump

Installation and Operating Instructions for Model:

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS
CAREFULLY BEFORE INSTALLING OR OPERATING
THIS CONTROL COULD CAUSE PERSONAL INJURY
AND/OR PROPERTY DAMAGE.

Save these instructions for future use!

APPLICATIONS

SPECIFICATIONS

Electrical Rating:

Battery Power .................................................... mV to 30 VAC, NEC Class II, 50/60 Hz or DC

Input-Hardwire ................................................... 20 to 30 VAC

Terminal Load ........................................................... 1.5 A per terminal, 2.5A maximum all terminals combined
Setpoint Range ......................................................... 45° to 90°F (7° to 32°C)
Differential (Single Stage) ......................................... Heat 0.6°F; Cool 1.2°F (adjustable)
Differential (Heat Pump) ........................................... Heat 1.2°F; Cool 1.2°F (adjustable)
Operating Ambient .................................................... 32° to +105°F (0° to +41°C)
Operating Humidity ................................................... 90% non-condensing max.
Shipping Temperature Range ................................... -40° to +150°F (-40° to +65°C)
Dimensions Thermostat ............................................ 3.4”H x 4.4”W x 1.3”D

www.white-rodgers.com

1F85ST-0422 Thermostat

with Spanish Display

Model

Programming Choices

1F85ST-0422

5/1/1 Day

5/2 Day

Non-Programmable

ATTENTION: MERCURY NOTICE

This product does not contain mercury. However, this
product may replace a product that contains mercury.

Mercury and products containing mercury must not be
discarded in household trash. Do not touch any spilled
mercury. Wearing non-absorbent gloves, clean up any
spilled mercury and place in a sealed container. For proper
disposal of a product containing mercury or a sealed
container of spilled mercury, place it in a suitable shipping
container. Refer to

www.white-rodgers.com

for location to

send product containing mercury.

To prevent electrical shock and/or equipment damage,
disconnect electric power to system at main fuse or
circuit breaker box until installation is complete.

CAUTION

!

THERMOSTAT APPLICATION GUIDE

Description

Heat Pump (No Aux. or Emergency Heat)

Yes

Heat Pump (with Aux. or Emergency Heat)

Yes

Systems with up to 2 Stages Heat, 2 Stages Cool

Yes

Heat Only Systems (with optional fan switch)

Yes

Millivolt Heat Only Systems – Floor or Wall Furnaces

Yes

Cool Only Systems

Yes

Gas or Oil Heat

Yes

Electric Furnace

Yes

Hydronic (Hot Water) Zone Heat – 2 Wires

Yes

Hydronic (Hot Water) Zone Heat – 3 Wires

Yes

Index

Page

Installation

2

Wiring Connections

2

Thermostat Quick Reference

3

Installer Confi guration Menu

4

Operating Your Thermostat

6

Programming

6

Troubleshooting

8

PART NO. 37-6954B

Replaces 37-6954A

0905

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - INSTALLATION; WARNING; Remove Old Thermostat; WIRING CONNECTIONS

2 INSTALLATION Thermostat installation and all components of the control system shall conform to Class II circuits per the NEC code. WARNING ! Remove Old Thermostat A standard heat/cool thermostat consists of three basic parts:1) The cover, which may be either a snap-on or hinge type.2) The base, wh...

Page 3 - THERMOSTAT QUICK REFERENCE; Home Screen Description; indicates good power level; Cambiar

3 THERMOSTAT QUICK REFERENCE Figure 3 – Home Screen Display Home Screen Description Programming and Confi guration Items 1 “Sistema On” indicates when heating or cooling stage is energized. “Sistema On +2” indicates when a second stage is energized. 2 The word Retener (Hold) is displayed when the th...

Page 4 - INSTALLER/CONFIGURATION MENU

4 INSTALLER/CONFIGURATION MENU With thermostat in Heat, Cool or Auto, in normal operation, press the Menu button for at least 5 seconds. The display will show item #1 in the table below. Press Menu to advance to the next menu item. Press or to change an item option. Shaded items are not available to...

Other White Rodgers Models

All White Rodgers Other