  • Page 2 – INSTALLATION; REMOVE OLD THERMOSTAT; labels enclosed with the new thermostat.; BATTERY LOCATION; Figure 1. Back of thermostat base; Figure 2. Thermostat base
  • Page 3 – Relay contacts shown are thermostatically operated.; Figure 3. Typical wiring diagram for single transformer systems
  • Page 4 – CHECK THERMOSTAT OPERATION; Fan Operation; LOCKOUT BYPASS OPTION; simply press
  • Page 5 – OPERATION; THE THERMOSTAT BASE; The Thermostat Buttons and Switches; OPERATING FEATURES; C CONVERTIBILITY— When the thermostat is in the; TROUBLESHOOTING
Loading the manual

T o p r e v e n t e l e c t r i c a l s h o c k a n d / o r e q u i p m e n t
d a m a g e , d i s c o n n e c t e l e c t r i c p o w e r t o s y s t e m a t
m a i n f u s e o r c i r c u i t b r e a k e r b o x u n t i l i n s t a l l a t i o n
i s c o m p l e t e .

Do not use on circuits exceeding specified voltage.
Higher voltage will damage control and could cause
shock or fire hazard.

Do not short out terminals on gas valve or primary
control to test. Short or incorrect wiring will damage
thermostat and could cause personal injury and/or
property damage.

Printed in U.S.A.

DESCRIPTION

1F83-51

Non-Programmable Electronic

Digital Multi-Stage Thermostat

INSTALLATION AND

OPERATION INSTRUCTIONS

PART NO. 37-5916C

Replaces 37-5916B

0005

Operator: Save these instructions for future use!

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.

Your new White-Rodgers Digital Multi-stage Thermostat uses
the technology of a solid-state microcomputer to provide precise
temperature control.

Features:

• Simultaneous heat and cool program storage

• Optional C terminal (dual power option)

PRECAUTIONS

SPECIFICATIONS

• LCD continuously displays room temperature

°

F/

°

C convertibility

• Temperature range 45

°

to 90

°

F

• Two-stage heat/two-stage cool

This thermostat is intended for use with a 24-volt system; do not
use this thermostat with a millivolt or line voltage system. If in
doubt about whether your wiring is millivolt, line, or low voltage,
have it inspected by a qualified heating and air conditioning
contractor or electrician.

Do not exceed the specification ratings.

All wiring must conform to local and national electrical codes and
ordinances.

This control is a precision instrument, and should be handled
carefully. Rough handling or distorting components could cause
the control to malfunction.

ELECTRICAL DATA
Electrical Rating:

20 to 30 VAC 50/60 Hz. or D.C.
0.05 to 1.5 Amps (Load per terminal)
1.5 Amps Maximum Total Load (All terminals combined)

THERMAL DATA
Setpoint Temperature Range:

45

°

F to 90

°

F (7

°

C to 32

°

C)

Operating Ambient Temperature Range:

32

°

F to 105

°

F

Operating Humidity Range:

0 to 90% RH (non-condensing)

Shipping Temperature Range:

-40

°

F to 150

°

F

APPLICATIONS

For use with:

• Heat/cool systems with up to two stages heat, two

stages cool

DO NOT USE WITH:

• Millivolt systems
• Systems exceeding 30 VAC and 1.5 amps
• 3-wire zoned hydronic heating systems

CAUTION

!

WARNING

!

WHITE-RODGERS DIVISION
EMERSON ELECTRIC CO.
9797 REAVIS ROAD
ST. LOUIS, MISSOURI 63123-5398

WHITE-RODGERS

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - INSTALLATION; REMOVE OLD THERMOSTAT; labels enclosed with the new thermostat.; BATTERY LOCATION; Figure 1. Back of thermostat base; Figure 2. Thermostat base

2 INSTALLATION REMOVE OLD THERMOSTAT 1. Shut off electricity at the main fuse box until installation is complete. Ensure that electrical power is disconnected. 2. Remove the front cover of the old thermostat. With wires still attached, remove wall plate from the wall. If the oldthermostat has a wall...

Page 3 - Relay contacts shown are thermostatically operated.; Figure 3. Typical wiring diagram for single transformer systems

3 NOTE NOTE The following wiring diagrams show typical terminal identifica-tion and wiring. For proper installation, refer to the originalmanufacturer's instructions. Relay contacts shown are thermostatically operated. C* R Y2 Compressor Contactor Stage 1 Heat Relay Stage 1 Heat Relay Stage 2 Thermo...

Page 4 - CHECK THERMOSTAT OPERATION; Fan Operation; LOCKOUT BYPASS OPTION; simply press

4 CHECK THERMOSTAT OPERATION If at any time during testing, your system does not operateproperly, contact a qualified serviceperson. Fan Operation 1. Turn on power to the system. 2. Move SYSTEM switch to OFF position. 3. Move FAN switch to ON. The blower should begin to operate. 4. Move FAN switch t...