White Rodgers 1F82-0261 - Manual
White Rodgers 1F82-0261 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – INSTALLATION; HP-SS SWITCH AND FAN SWITCH
- Page 3 – or; ENERGY MANAGEMENT RECOVERY; OFF; the temperature settings will change at; WIRING DIAGRAMS; Figure 2. Typical wiring diagram for single transformer systems
- Page 4 – THERMOSTAT QUICK REFERENCE; The Thermostat Buttons and Switches
- Page 5 – INSTALLER/CONFIGURATION MENU; ) System Confi guration; feature is active and making adjustments, the; value that is set, 1 being the least adjustment; ) Select Energy Management Recovery
- Page 6 – CAUTION; OPERATION; CHECK THERMOSTAT OPERATION; Fan Operation
- Page 7 – MANUAL OPERATION; Planning Your Program; PROGRAMMING; Entering Your Program
- Page 8 – Enter Heating Program
- Page 9 – TROUBLESHOOTING; Reset Operation; and PRGM buttons simultaneously. If
- Page 10 – STAGING; Second Stage - Auxiliary Heat
- Page 11 – NOTES
1
Blue 2” Heat Pump Thermostat
Heat Pump or Single Stage
Installation and Operating Instructions
Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS
CAREFULLY BEFORE INSTALLING OR OPERATING THIS
CONTROL COULD CAUSE PERSONAL INJURY AND/OR
PROPERTY DAMAGE.
APPLICATIONS
1F82-0261 Thermostat
Model
Programming Choices
1F82-0261
5/1/1 Day Programmable
SPECIFICATIONS
Electrical Rating:
Battery Power ................................................. mV to 30 VAC, 50/60 Hz or DC
Input-Hardwire ................................................ 20 to 30 VAC
Terminal Load ........................................................ 1.0 A per terminal, 1.5A maximum all terminals combined
Setpoint Range ...................................................... 45° to 90°F (7° to 32°C)
Differential (Single Stage) ...................................... Heat 0.8°F; Cool 1.2°F (adjustable)
Differential (Heat Pump) ........................................ Heat 1.2°F; Cool 1.2°F (adjustable)
Operating Ambient ................................................. 32° to +105°F (0° to +41°C)
Operating Humidity ................................................ 90% non-condensing max.
Shipping Temperature Range ................................ -40° to +150°F (-40° to +65°C)
Dimensions Thermostat ......................................... 3-3/4”H x 4-3/4”W x 1-1/2”D
PRECAUTIONS
To prevent electrical shock and/or equipment damage,
disconnect electric power to system at main fuse or
circuit breaker box until installation is complete.
CAUTION
!
Do not use on circuits exceeding specifi ed voltage.
Higher voltage will damage control and could cause
shock or fi re hazard.
Thermostat installation and all components of the
system shall conform to Class II (current limited)
circuits per the NEC code. Failure to do so could cause
a fi re hazard.
WARNING
!
PART NO. 37-7022B
Replaces 37-7022A
0925
www.white-rodgers.com
YOUR THERMOSTAT REPLACES
Description
Heat Pump (No Aux. or Emergency Heat)
Yes
Heat Pump (with 1 Aux. or Emergency Heat Stage)
Yes
Standard Heat & Cooling Systems
Yes
Two Stage Heat & Two Stage Cool
No
Standard Heat Only Systems
Yes
Millivolt Heat Only Systems - Floor or Wall Furnaces
Yes
Standard Central Air Conditioning
Yes
Gas or Oil Heat
Yes
Electric Furnace
Yes
Hydronic (Hot Water) Zone Heat – 2 Wires
Yes
Hydronic (Hot Water) Zone Heat – 3 Wires
No
Index
Page
Installation
2
Wiring Diagrams
3
Thermostat Quick Reference
4
Installer Confi guration Menu
5
Operation
6
Programming
7
Troubleshooting
9
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 REMOVE OLD THERMOSTAT 1. Shut off electricity at the main fuse box until installation is complete. Ensure that electrical power is disconnected. 2. Remove the front cover of the old thermostat. With wires still attached , remove wall plate from the wall. If the old thermostat has a wall mounting p...
3 INSTALLATION install fresh “AA” alkaline batteries immediately. For best results, use new premium brand alkaline batteries such as Duracell® or Energizer®. We recommend replacing batteries every 2 years. If the home is going to be unoccupied for an extended period (over 3 months) and is displayed,...
4 WIRING DIAGRAMS L R C SYSTEM MONITOR SWITCH G W2 Figure 4. Typical wiring diagram for two transformer systems with safety circuits in BOTH systems Changeover Relay* Y O/B Compressor Contactor * Changeover Relay is energized in COOL when O/B switch is in the “O” position Changeover Relay is energiz...