Table of Contents:

  • Page 2 – INSTALLATION; REMOVE OLD THERMOSTAT; labels enclosed with the new thermostat.; INSTALLING THE THERMOSTAT; Figure 1. Back of thermostat base; Figure 2. Thermostat base
  • Page 3 – Relay contacts shown are thermostatically operated.; Figure 3. Typical wiring diagram for single transformer systems
  • Page 4 – CHECK THERMOSTAT OPERATION; Fan Operation; LOCKOUT BYPASS OPTION; while testing thermostat operation, simply press
  • Page 5 – OPERATION; THE THERMOSTAT BASE; The Thermostat Buttons and Switches; HEAT is displayed when the SYSTEM button has been; OPERATING FEATURES; C CONVERTIBILITY — Press SET TIME and HOLD
  • Page 6 – Set Current Time and Day
  • Page 7 – Enter Cooling Program; If the outside temperature is below 50; CAUTION; CHECK YOUR PROGRAMMING
Loading the manual

To prevent electrical shock and/or equipment damage
disconnect electric power to system at main fuse or
circuit breaker box until installation is complete.

Do not use on circuits exceeding specified voltage.
Higher voltage will damage control and could cause
shock or fire hazard.

Do not short out terminals on gas valve or primary
control to test. Short or incorrect wiring will damage
thermostat and could cause personal injury and/or
property damage.

Printed in U.S.A.

DESCRIPTION

1F80-71

Programmable Electronic

Digital Automatic Changeover Single Stage Thermostat

INSTALLATION AND

OPERATION INSTRUCTIONS

PART NO. 37-6120A

9934

Operator: Save these instructions for future use!

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.

Your new White-Rodgers 5-Day/2-Day Single Stage Digital
Thermostat uses the technology of a solid-state microcomputer
to provide precise time/temperature control. This thermostat
offers you the flexibility to design heating and cooling programs
that fit your needs.

Features:

• Separate 5-day (weekday) and 2-day (weekend) programming

with four separate time/temperature periods per program

• Simultaneous heat and cool program storage
• Automatic changeover
• Optional C terminal (dual power option)

PRECAUTIONS

SPECIFICATIONS

• Optional Energy Management Recovery (EMR)
• Optional B and O terminals
• Preprogrammed temperature control
• LCD continuously displays set point, and alternately dis-

plays time and room temperature

• Temperature override until next program period
• Manual program override (HOLD temperature)

°

F/

°

C convertibility

• Temperature range 45

°

to 90

°

F

• Keypad lockout
• Armchair programming capability

This thermostat is intended for use with a 24-volt system; do not
use this thermostat with a millivolt or line voltage system. If in
doubt about whether your wiring is millivolt, line, or low voltage,
have it inspected by a qualified heating and air conditioning
contractor or electrician.

Do not exceed the specification ratings.

All wiring must conform to local and national electrical codes and
ordinances.

This control is a precision instrument, and should be handled
carefully. Rough handling or distorting components could cause
the control to malfunction.

ELECTRICAL DATA
Electrical Rating:

8 to 30 VAC 50/60 Hz. or D.C.
0.05 to 1.5 Amps (Load per terminal)
1.5 Amps Maximum Total Load (All terminals combined)

THERMAL DATA
Setpoint Temperature Range:

45

°

F to 90

°

F (7

°

C to 32

°

C)

Operating Ambient Temperature Range:

32

°

F to 105

°

F

Operating Humidity Range:

0 to 90% RH (non-condensing)

Shipping Temperature Range:

-40

°

F to 150

°

F

APPLICATIONS

For use with:

Standard heat/cool or heat only systems

Electric heat systems

Gas or oil fired systems

Gas systems with intermittent ignition devices (I.I.D.)
and/or vent dampers

Hydronic (hot water or steam) systems

DO NOT USE WITH:

Multi-stage systems

Systems exceeding 30 VAC and 1.5 amps

Millivolt systems

3-wire zoned hydronic heating systems

CAUTION

!

WARNING

!

WHITE-RODGERS DIVISION
EMERSON ELECTRIC CO.
9797 REAVIS ROAD
ST. LOUIS, MISSOURI 63123-5398

WHITE-RODGERS

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - INSTALLATION; REMOVE OLD THERMOSTAT; labels enclosed with the new thermostat.; INSTALLING THE THERMOSTAT; Figure 1. Back of thermostat base; Figure 2. Thermostat base

2 INSTALLATION REMOVE OLD THERMOSTAT 1. Shut off electricity at the main fuse box until installation is complete. Ensure that electrical power is disconnected. 2. Remove the front cover of the old thermostat. With wires still attached, remove wall plate from the wall. If the oldthermostat has a wall...

Page 3 - Relay contacts shown are thermostatically operated.; Figure 3. Typical wiring diagram for single transformer systems

3 NOTE NOTE The following wiring diagrams show typical terminal identifica-tion and wiring. For proper installation, refer to the originalmanufacturer's instructions. Relay contacts shown are thermostatically operated. C* R O B Energized in HEAT Cooling System Heating System Thermostat Control Circu...

Page 4 - CHECK THERMOSTAT OPERATION; Fan Operation; LOCKOUT BYPASS OPTION; while testing thermostat operation, simply press

4 CHECK THERMOSTAT OPERATION If at any time during testing, your system does not operateproperly, contact a qualified serviceperson. Fan Operation 1. Turn on power to the system. 2. Press SYSTEM button until the system is OFF. 3. Move FAN switch to ON. The blower should begin to operate. 4. Move FAN...