Table of Contents:

  • Page 2 – INSTALLATION; REMOVE OLD THERMOSTAT; labels enclosed with the new thermostat.; ELECTRIC HEAT OR SINGLE-STAGE; ATTACH THERMOSTAT BASE TO WALL; HEATING SYSTEMS; Figure 1. Back of thermostat base; Figure 2. Thermostat base; NOTE
  • Page 3 – Figure 7. Typical wiring diagram for; Figure 8. Typical wiring diagram for
  • Page 4 – CAUTION; CHECK THERMOSTAT OPERATION; Fan Operation; THE THERMOSTAT BASE; The Thermostat Buttons and Switches; OPERATION
  • Page 5 – OPERATING FEATURES; C CONVERTIBILITY — Press and hold SET TIME and; PROGRAMMING YOUR THERMOSTAT
  • Page 6 – Entering Your Program; Set Current Time and Day; Enter Heating Program; Enter Cooling Program; If the outside temperature is below 50; CHECK YOUR PROGRAMMING
Loading the manual

To prevent electrical shock and/or equipment dam-
age, disconnect electric power to system at main fuse
or circuit breaker box until installation is complete.

Do not use on circuits exceeding specified voltage.
Higher voltage will damage control and could cause
shock or fire hazard.

Do not short out terminals on gas valve or primary
control to test. Short or incorrect wiring will damage
thermostat and could cause personal injury and/or
property damage.

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.

DESCRIPTION

Your new White-Rodgers 5-Day/2-Day Digital Thermostat uses
the technology of a solid-state microcomputer to provide precise
time/temperature control. This thermostat offers you the flexibil-
ity to design heating and cooling programs that fit your needs.

Features:

• Battery powered (3 “AA” Energizer

®

alkaline batteries in-

cluded).

• Separate 5-day (weekday) and 2-day (weekend) programming

• Simultaneous heat and cool program storage

• Preprogrammed temperature control

• Four separate time/temperature settings per 24-hour period

• LCD continuously displays set point, and alternately dis-

plays time and room temperature

• Temperature override until next program period

• Manual program override (HOLD temperature)

• User may select either 12- or 24-hour clock display

°

F/

°

C convertibility

• Temperature range 45

°

to 90

°

F

• Standard five terminals for single or two-transformer sys-

tems

• B and O terminals for single stage heat pumps or damper

operation

SPECIFICATIONS

ELECTRICAL DATA
Electrical Rating:

8 to 30 VAC 50/60 Hz. or D.C.
0.05 to 1.5 Amps (Load per terminal)
1.5 Amps Maximum Total Load (All terminals combined)

THERMAL DATA
Setpoint Temperature Range:

45

°

F to 90

°

F (7

°

C to 32

°

C)

Operating Ambient Temperature Range:

32

°

F to 105

°

F

Operating Humidity Range:

0 to 90% RH (non-condensing)

Shipping Temperature Range:

-40

°

F to 150

°

F

APPLICATIONS

For use with:

Standard heat/cool or heat only systems

Electric heat systems

Gas or oil fired systems

Gas systems with intermittent ignition devices (I.I.D)
and/or vent dampers

Hydronic (hot water or steam) systems

Single-stage heat pump systems

Millivolt systems

DO NOT USE WITH:

Multi-stage systems

Systems exceeding 30 VAC and 1.5 amps

3-wire zoned hydronic heating systems

1F80-41

Programmable Electronic Digital Thermostat

Printed in U.S.A.

R

WHITE-RODGERS DIVISION
EMERSON ELECTRIC CO.
9797 REAVIS ROAD
ST. LOUIS, MISSOURI 63123-5398

WHITE-RODGERS

INSTALLATION AND

OPERATION INSTRUCTIONS

PRECAUTIONS

This thermostat is intended for use with a low voltage system; do
not use this thermostat with a line voltage system. If in doubt
about whether your wiring is millivolt, line, or low voltage, have
it inspected by a qualified heating and air conditioning contractor
or licensed electrician.

Do not exceed the specification ratings.

All wiring must conform to local and national electrical codes and
ordinances.

This control is a precision instrument, and should be handled
carefully. Rough handling or distorting components could cause
the control to malfunction.

PART NO. 37-5604B

Replaces 37-5604A

9602

Operator: Save these instructions for future use!

CAUTION

!

WARNING

!

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - INSTALLATION; REMOVE OLD THERMOSTAT; labels enclosed with the new thermostat.; ELECTRIC HEAT OR SINGLE-STAGE; ATTACH THERMOSTAT BASE TO WALL; HEATING SYSTEMS; Figure 1. Back of thermostat base; Figure 2. Thermostat base; NOTE

2 INSTALLATION REMOVE OLD THERMOSTAT 1. Shut off electricity at the main fuse box until installation is complete. Ensure that electrical power is disconnected. 2. Remove the front cover of the old thermostat. With wires still attached, remove wall plate from the wall. If the oldthermostat has a wall...

Page 3 - Figure 7. Typical wiring diagram for; Figure 8. Typical wiring diagram for

3 RH Y 24 VAC 120 VAC Hot Neutral THERMOSTAT SYSTEM G W Figure 10. Typical wiring diagram for heat pump with heat active changeover relay TRANSFORMER Changeover Relay* RC O B JUMPER WIRE Compressor Contactor JUMPER WIRE * Changeover Relay is energized when the system switch is in the HEAT position F...

Page 4 - CAUTION; CHECK THERMOSTAT OPERATION; Fan Operation; THE THERMOSTAT BASE; The Thermostat Buttons and Switches; OPERATION

4 CAUTION ! CHECK THERMOSTAT OPERATION If at any time during testing your system does not operateproperly, contact a qualified serviceperson. Fan Operation If your system does not have a G terminal connection, skip toHeating System. 1. Turn on power to the system. 2. Move FAN switch to ON position. ...