White Rodgers 1F80-241 - Manual
White Rodgers 1F80-241 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – INSTALLATION; REMOVE OLD THERMOSTAT; ELECTRIC HEAT OR SINGLE-STAGE; ATTACH THERMOSTAT BASE TO WALL; HEATING SYSTEMS; CHECK THERMOSTAT OPERATION; Fan Operation
- Page 3 – Figure 2. Typical wiring diagram for; Figure 7. Typical wiring diagram for heat pump; Figure 3. Typical wiring diagram for; thermostat cover; THE THERMOSTAT BASE; CAUTION; OPERATION; Cooling System; COOL; The Thermostat Buttons and Switches
- Page 4 – CONFIGURATION MENU; Step; Configuration Menu; The Display
- Page 5 – OPERATING FEATURES; Planning Your Program; Set Current Time and Day
- Page 6 – Enter Heating Program; Enter Cooling Program; CHECK YOUR PROGRAMMING
Do not use on circuits exceeding specified voltage.
Higher voltage will damage control and could cause
shock or fire hazard.
Do not short out terminals on gas valve or primary
control to test. Short or incorrect wiring will damage
thermostat and could cause personal injury and/or
property damage.
Thermostat installation and all components of the
system shall conform to Class II circuits per the NEC
code.
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
DESCRIPTION
Your new White-Rodgers 5-Day/1-Day/1-Day Digital Thermo-
stat uses the technology of a solid-state microcomputer to
provide precise time/temperature control. This thermostat offers
you the flexibility to design heating and cooling programs that fit
your needs.
Features:
• 24 Volt System powered.
• Separate 5-day (weekday), 1-day (Sat) and 1-day (Sun) pro-
gramming with four separate time/temperature settings per day
• Simultaneous heat and cool program storage
• Preprogrammed temperature control
• Backlit display
• LCD continuously displays set point, and alternately dis-
plays time and room temperature
• Temperature override until next program period
• Manual program override (HOLD temperature)
• Temporary HOLD
•
°
F/
°
C convertibility
• Temperature range 45
°
to 90
°
F
• RC, RH, C, W, Y, G , O and B terminals
• B and O terminals for single stage heat pumps (no auxiliary
heat) or damper operation
• Program storage in case of power loss.
SPECIFICATIONS
ELECTRICAL DATA
Electrical Rating:
18 to 30 VAC 50/60 Hz. or D.C.
0.05 to 1.0 Amps (Load per terminal)
1.5 Amps Maximum Total Load
(All terminals combined)
THERMAL DATA
Setpoint Temperature Range:
45
°
F to 90
°
F (7
°
C to 32
°
C)
Operating Ambient Temperature Range:
32
°
F to 105
°
F
Operating Humidity Range:
0 to 90% RH (non-condensing)
Shipping Temperature Range:
-4
°
F to 150
°
F
APPLICATIONS
For use with:
•
Standard heat/cool or heat only systems
•
Electric heat systems
•
Gas or oil fired systems
•
Gas systems with intermittent ignition devices (I.I.D.)
and/or vent dampers
•
Hydronic (hot water or steam) systems
•
Single-stage heat pump systems (no auxiliary heat)
DO NOT USE WITH:
•
Millivolt systems
•
Multi-stage systems
•
Systems exceeding 30 VAC and 1.5 amps
•
3-wire zoned hydronic heating systems
1F80-241
Programmable Electronic Digital Thermostat
Printed in U.S.A.
PART NO. 37-6313A
0144
WHITE-RODGERS
EMERSON ELECTRIC CO.
9797 REAVIS ROAD
ST. LOUIS, MISSOURI 63123-5398
www.white-rodgers.com
INSTALLATION AND
OPERATION INSTRUCTIONS
PRECAUTIONS
CAUTION
!
This thermostat is intended for use with a low voltage system; do
not use this thermostat with a line voltage system. If in doubt
about whether your wiring is millivolt, line, or low voltage, have
it inspected by a qualified heating and air conditioning contractor
or electrician.
Do not exceed the specification ratings.
All wiring must conform to local and national electrical codes and
ordinances.
This control is a precision instrument, and should be handled
carefully. Rough handling or distorting components could cause
the control to malfunction.
To prevent electrical shock and/or equipment dam-
age, disconnect electric power to system at main fuse
or circuit breaker box until installation is complete.
WARNING
!
Operator: Save these instructions for future use!
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 INSTALLATION REMOVE OLD THERMOSTAT 1. Shut off electricity at the main fuse box until installation is complete. Ensure that electrical power is disconnected. 2. Remove the front cover of the old thermostat. With wires still attached, remove wall plate from the wall. If the old thermostat has a wal...
3 RH Y 24 VAC 120 VAC Hot Neutral THERMOSTAT SYSTEM G W Figure 5. Typical wiring diagram for heat/cool, 5-wire, two-transformer systems with common connection (required) HEATING TRANSFORMER Heating System Fan Relay CoolingSystem RC 24 VAC 120 VAC Hot Neutral COOLING TRANSFORMER O B C RH Y 24 VAC 120...
4 CONFIGURATION MENU The configuration menu allows you to set certain thermostatoperating characteristics to your system or personal requirements. Press RUN to make sure the thermostat is in the run programmode, then press PRGM and RUN at the same time to enter theconfiguration menu. The display wil...