Table of Contents:

  • Page 2 – NEW THERMOSTAT OPERATION
  • Page 3 – Síntoma; LÍNEA DE; White-Rodgers es una división
  • Page 4 – Instrucciones de instalación para:; Acción rápida
Loading the manual

Do not use on circuits exceeding specifi ed voltage. Higher voltage will
damage control and could cause shock or fi re hazard.

Do not short out terminals on gas valve or primary control to test. Short or
incorrect wiring will damage thermostat and could cause personal injury
and / or property damage.

Thermostat installation and all components of the system shall conform
to Class II circuits per the NEC code.

YOUR THERMOSTAT REPLACES

System Models

Standard Heat Only Systems

1E30N-910

1E50N-301

Electric Furnace

Heat Pump (No Aux or Emergency Heat)

Gas or Oil Heat

Millivolt Heat Only Systems

1

PREPARATIONS

Assemble tools required: power drill, fl at blade screwdriver, wire cutter/stripper, level.

Failure to follow and read all instructions carefully before installing or op -
erating this control could cause personal injury and / or property damage.

2

THERMOSTAT FEATURES

Captive

screws

Mounting

Screw

Mounting

Screw

COVER

THERMOSTAT

BASE

WALLPLATE

SWITCHING

SUBBASE

S
Y
S
T

E

M

O
F
F

H
E
A
T

G

W

RH

Mounting

Screw

50

60

70

80

90

50 60

70 80

90

4

Figure 1. Thermostat with subbase or wallplate

To prevent electrical shock and/or equipment damage, disconnect electrical
power to the system at the main fuse or circuit breaker until installation is
complete.

CAUTION

!

Before removing wires from old thermostat’s switching subbase, label each wire with
the terminal designation it was removed from.

1. Remove

Old

Thermostat:

A standard thermostat consists of three basic parts:

a. The cover, which may be either a snap-on or hinge type.

b. The base, which is removed by loosening all captive screws.

c.

The switching subbase, which is removed by unscrewing the mounting

screws that hold it on the wall or adaptor plate.

Make a note here

of the anticipator setting on the old thermostat

for future reference and use in step 5.

The heat anticipator pointer, if adjustable, will be set at one of a series of numbers
representing the current rating of the primary control in your furnace. The number will
be one of the following: .2, .4, .8, etc. or 0.2, 0.4, 0.8, etc.

3

3

REMOVING OLD THERMOSTAT (cont’d)

If no heat anticipator/indication is showing, do not be concerned ; move on to the
next step.

AT TENTION !

This product does not contain mercur y. However, this product may

replace a unit which contains mercur y.

Do not open mercur y cells. If a cell becomes damaged, do not touch any spilled
mercur y. Wearing non-absorbent gloves, take up the spilled mercur y and place into
a container which can be sealed. If a cell becomes damaged, the unit should be
discarded.

Mercur y must not be discarded in household trash. When the unit this product is
replacing is to be discarded, place in a suitable container. Refer to www.white-
rodgers.com for location to send product containing mercur y.

4

MOUNTING AND WIRING

WARNING

!

A. Remove base from subbase or wallplate :

Loosen the screws on the base and

remove.

B. Mount switching subbase or wallplate :

Use the screws provided to mount the

subbase or wallplate to wall (see Fig. 1).

C. Attach wires to appropriate terminals :

Two wire systems (Heat Only). Attach

one wire to RH and one to wire W.

D. Mount Thermostat Base :

Gently push excess wire back into the wall opening

and plug hole with a fi re-resistant material, such as fi berglass insulation to pre-
vent drafts from affecting thermostat operation. Mount the thermostat base to
the subbase or wallplate using the three captive screws on the thermostat base.
(See Fig. 1) Tighten the screws securely. Proceed to Step # 5.

TERMINAL CROSS REFERENCE CHART

New

Thermostat

Other

Manufacturers’

Terminal Designation

Terminal Designation

R H

4

R H

M

R 5

R

W

W

W

H

4

W

5

Set anticipator to match the setting of your old thermostat you noted in Step 3, or, the
anticipator should be set to match the current rating stamped on your main heating
control. The heat anticipator is adjustable from 0.15 to 1.2 amps. Adjust the anticipa-
tor by rotating the contact arm (see fi g. 2). The anticipator setting is indicated by the
numbers on the base that the pointer points to. If you are unsure where to set the
anticipator contact the heater manufacturer for a recommended setting.

Move the pointer

counterclock wise to

lengthen

heating system cycles; move

clock wise to shorten

heating cycles.

Adjustments should not be greater than
1/ 2 marking at a time.

For millivolt operation, rotate contact arm to
Millivolt Link.

Snap on Cover

: Carefully align the cover

with the base and snap the cover onto
the base.

Rotate contact arm
to adjust heat anticipator

Arrow points to the
current rating of
the primary control

Millivolt Link

REMOVING OLD THERMOSTAT

Take care when securing and routing wires so they do not short to adjacent
terminals or rear of thermostat. Personal injury and/or property damage may
occur.

CAUTION

!

SET HEAT ANTICIPATOR

Figure 2. Anticipator adjustment

Installation Instructions for:

Vertical
Snap Action

1E30N-910
1E50N-301

www.white-rodgers.com

PART NO. 37-6844B

Replaces 37-6844A

0920

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - NEW THERMOSTAT OPERATION

Symptom Possible Cause Corrective Action No Heat/ No Fan 1. Blown fuse or tripped circuit breaker. Replace fuse or reset breaker. (common problems) 2. Furnace power switch to OFF. Turn switch to ON. 3. Furnace blower compartment door or Replace door panel in proper position to engage panel loose or ...

Page 3 - Síntoma; LÍNEA DE; White-Rodgers es una división

7 6 8 FUNCIONAMIENTO DEL NUEVO TERMOST AT O Este termostato es fácil de usar. Una vez encendida la alimentación, utilice el interruptor del sistema para seleccionar calefacción, o para apagar el sistema de calefacción. ESPECIFICACIONES DA TOS ELÉCTRICOS Características del interruptor .................

Page 4 - Instrucciones de instalación para:; Acción rápida

No u tili zar en c irc uito s q ue e xce dan el v olta je e spe cifi cad o y a q ue l os v olta jes más alto s dañ ará n el c ont rol y p ued en c aus ar r ies gos d e ele ctr ocu ció n o inc end io. No cor toc irc uite las ter min ale s de la vál vul a de gas ni d el c ont rol prin cip al p ara pro...