  • Page 2 – SPECIFICATIONS; ROUTE WIRES TO LOCATION; INSTALLATION; SELECT THERMOSTAT LOCATION; NOTE
  • Page 3 – Figure 4. Calibrating Thermostat Thermometer; CALIBRATING THERMOMETER ON; Figure 3. Parts of Thermostat; OPERATION & MAINTENANCE; CAUTION
  • Page 4 – CALIBRATING THERMOSTAT; Figure 5. Calibrating Thermostat
  • Page 5 – PRÉCAUTIONS; Thermostat d’ambiance à millivolts; INSTRUCTIONS D’INSTALLATION; TABLE DES MATIÈRES; AVERTISSEMENT; DESCRIPTION; ATTENTION
  • Page 6 – FICHE ÉLECTRIQUE; LONGUEUR DES FILS DU THERMOSTAT
  • Page 7 – MODE D’EMPLOI ET ENTRETIEN; ÉTALONNAGE DU THERMOMÈTRE; Figure 3. Les parties du thermostat; Figure 2. Schéma de câblage typique
  • Page 8 – Figure 5. Étalonnage du thermostat; ÉTALONNAGE DU THERMOSTAT
Loading the manual

This control is a precision instrument, and should be
handled carefully. Rough handling or distorting compo-
nents could cause the control to malfunction.

To prevent electrical shock and/or equipment
damage, disconnect electric power to system, at
main fuse or circuit breaker box, until installation
is complete.

Do not short out terminals on gas valve or primary
control to test. Short or incorrect wiring will burn
out heat anticipator and could cause personal
injury and/or property damage.

Do not use on circuits exceeding 750 millivolts.
Higher voltage will damage control and could
cause shock or fire hazard.

Printed in U.S.A.

WHITE-RODGERS

R

WHITE-RODGERS DIVISION

EMERSON ELECTRIC CO.
9797 REAVIS RD., ST. LOUIS, MO. 63123
(314) 577-1300, Fax (314) 577-1517

9999 HWY. 48, MARKHAM, ONT. L3P 3J3
(905) 475-4653, FAX (905) 475-4625

PART NO. 37-5583A

Replaces 37-9587C

9531

These low voltage thermostats are specially designed for
use on self-generating systems. They are non-antici-
pated, enabling them to be used on self-generated sys-
tems having pilot generator outputs from 250 to 750
millivolts.

ATTENTION!

This product contains mercury. There will not be any exposure to mercury under normal conditions of use. This product may replace a unit
which contains mercury. Do not open mercury cells. If a cell becomes damaged, do not touch any spilled mercury. Wearing non-absorbent
gloves, take up the spilled mercury with sand or other absorbent material and place into a container which can be sealed. If a cell becomes
damaged, the unit should be discarded. Mercury must not be discarded in household trash. When this unit or the unit it is replacing is to be
discarded, place in a suitable container and return to us at WHITE-RODGERS.

If in doubt about whether your wiring is millivolt, line, or low
voltage, have it inspected by a qualified heating and air
conditioning contractor, electrician, or someone familiar
with basic electricity and wiring.
Do not exceed the specification ratings.
All wiring must conform to local and national electrical
codes and ordinances.

CONTENTS

Description .......................................................... 1
Precautions ......................................................... 1
Specifications ...................................................... 2
Installation ........................................................... 2

Select Thermostat Location
Route Wires to Location
Attach Thermostat to Wall

Operation & Maintenance ................................... 3

Calibrating Thermometer
Calibrating Thermostat

PRECAUTIONS

1E30(W)/1F30(W)

Non-Anticipated

Millivolt Room Thermostat

INSTALLATION INSTRUCTIONS

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.

Operator: Save these instructions for future use!

DESCRIPTION

1E30

1F30

CAUTION

!

WARNING

!

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - SPECIFICATIONS; ROUTE WIRES TO LOCATION; INSTALLATION; SELECT THERMOSTAT LOCATION; NOTE

2 SPECIFICATIONS THERMAL DATA: Temperature Range: 10 ° to 32 ° C (50 ° to 90 ° F) Differential: 1.7 ° C (3 ° F) ROUTE WIRES TO LOCATION 1. If an old thermostat is being replaced and is in a satisfactory location, and the wiring appears to be ingood condition, use existing wiring. If in doubt, rewire...

Page 3 - Figure 4. Calibrating Thermostat Thermometer; CALIBRATING THERMOMETER ON; Figure 3. Parts of Thermostat; OPERATION & MAINTENANCE; CAUTION

3 To prevent electrical shock and/or equipmentdamage, disconnect electric power to system, atmain fuse or circuit breaker box, until installationis complete. This typical wiring diagram shows only terminal identifica-tion and wiring hook-up. Always refer to the wiring instruc-tions provided by the e...

Page 4 - CALIBRATING THERMOSTAT; Figure 5. Calibrating Thermostat

CALIBRATING THERMOSTAT This thermostat has been carefully adjusted at the factoryand should not require recalibration. Due to environmental conditions, during normal operationthere may be a few degrees difference between theindicator setting of the thermostat and actual room tem-perature. If the dis...