Vermont Casting 20DVT – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Brookhaven Direct Vent Gas Fireplace; PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS; Table of Contents
- Page 3 – OFF; PLEASE REVIEW THE FOLLOWING CAREFULLY; Locating Your Fireplace; Installation & Operating Instructions
- Page 4 – Framing Dimensions; 0DVT Fireplace Dimensions; Fireplace specifications and framing dimensions.
- Page 5 – Clearance to Combustibles; Combustible mantel leg minimum installation.; Hearth; Mantel Chart; Combustible mantel minimum installation.; Mantel Shelf
- Page 6 – DO NOT; Certified To; Vented Gas Fireplace Heaters
- Page 7 – INSTA VENT FREE; Typical gas supply installation.; Attach the wire to the ON/OFF switch and install; Remote switch wiring diagram for R models.; If vent termination is installed in an accessible loca-; General Venting; There must not be any obstruction
- Page 8 – General Venting Information - Termination Location; Canadian Installations
- Page 9 – Termination clearances.; General Information Assembling Vent Pipes; Canadian Installations:; Flex Vent Pipes; Apply high temperature sealant to 4” and 7” pipes.; Termination Clearances; of Caps
- Page 10 – How to Use the Vent Graph; Horizontal dimension from the outside face of the; ertical dimension from the fl; Twist Lock Pipes
- Page 11 – If a 90° elbow is fitted directly on top of the fireplace; Maximum horizontal run with no rise.; According to the vent graph (Page 10) the; Total angular variation = 270°; Maximum elbow usage.; Vertical Sidewall Installation; When using flex vent, the opening will have to; Combustible Walls
- Page 12 – Vent Opening for Combustible Wall; Locate vent opening on wall.
- Page 13 – Vertical Sidewall Installation; Install spacer springs.; Install the 4” flex then 7” flex to the termination.; Below Grade Installations
- Page 14 – Below grade installation.
- Page 15 – Minimum termination to roof clearance.; Proceed to plumb for additional openings through the
- Page 16 – Elbow; Vent components; Vent Components; Vent components; Venting Components; Venting Components; vent components
- Page 17 – Glass Information; Care must be taken to avoid breakage of the glass.; Operating Instructions; Cast Front Panel; Remove; Window Frame Assembly Removal; Unlock the frame window by pulling the handle of the; Window frame assembly removal.
- Page 18 – Place ember material on top of burner. Scatter the; Installation of Logs; LOGS; Log Rear; Log Identification Chart
- Page 19 – Large Lava Rock; Flame adjustment knob for SIT valve.; Flame adjustment knob for Honeywell valve.; LO; Honeywell Valve; Flame & Temperature Adjustment; Correct pilot flame appearance.; SIT Pilot; Inspecting the Venting System; Correct burner flame appearance for the 20DVT.
- Page 20 – FOR YOUR SAFETY READ BEFORE LIGHTING; WHAT TO DO IF YOU SMELL GAS; To Turn Off Gas To Heater; Lighting and Operating Instructions; Lighting Instructions; Euro SIT
- Page 21 – SIT NOVA 820 MILLIVOLT VALVE; Troubleshooting the Gas Control System; SYMPTOM
- Page 22 – Fuel Conversion Instructions; Conversions must be completed by qualified personnel; Remove mounting screws, pressure regulator tower; SIT; Burner Orifice Conversion; Burner housing assembly.
- Page 23 – Gas Conversion; Remove pilot orifice.; Pilot Orifice Conversion; Turn the gas supply valve and gas valve on and test; Back burner housing.
- Page 24 – Burner and Burner Compartment; Cleaning the Standing; If repair is necessary, it should be per-; Maintenance
- Page 25 – Burner Housing Assy
- Page 26 – Fuel Conversion Kits
- Page 27 – Remote Controls; Model; Ceramic Refractory Panels; Installation Instructions; Optional Trim Kits; MUST BE; Optional Cabinet; Rear ceramic panel placement.; Optional Accessories Available
- Page 31 – IF WARRANTY SERVICE IS NEEDED...; ) Contact your supplier. Make sure you have your warranty,; LIMITED LIFETIME WARRANTY; PRODUCT COVERED BY THIS WARRANTY
- Page 32 – Efficiency Ratings; EnerGuide Ratings; CFM Corporation
DO NOT STORE OR USE
GASOLINE OR OTHER
FLAMMABLE VAPORS AND
LIQUIDS IN THE VICINITY OF
THIS OR ANY OTHER
APPLIANCE.
WHAT TO DO IF YOU SMELL GAS:
•
Do not try to light any appliance.
•
Do not touch any electric switch;
do not use any phone in your
building.
•
Immediately call your gas
supplier from your neighbor’s
phone. Follow the gas suppliers
instructions.
•
If you cannot reach your gas
supplier call the fire department.
WARNING!
IF THE INFORMATION IN THIS
MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING
PROPERTY DAMAGE, PER-
SONAL INJURY OR LOSS OF
LIFE.
PLEASE READ THIS MANUAL
BEFORE INSTALLING AND
USING APPLIANCE
INSTALLER/CONSUMER
SAFETY INFORMATION
FOR YOUR SAFETY
Installation and service must
be performed by a qualified
installer, service agency or
the gas supplier.
Brookhaven
Direct Vent Model:
20DVT
Installation Instructions and
Homeowner’s Manual
10009459 2/07 Rev. 5
� � � � � � � � �
�������
����������
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
����
�����������
����
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Brookhaven Direct Vent Gas Fireplace 2 10009459 PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a CFM Corporation fireplace.IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure...
10009459 3 Brookhaven Direct Vent Gas Fireplace This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CSA-B149.1 Installation codes for Gas Burning Appliances and Equipment. For USA Installations follow local codes and/or the current ...
Brookhaven Direct Vent Gas Fireplace 4 10009459 Ref. 20DVT A 20” (508 mm) B 29 ¹⁄₂ ” (749 mm) C 13 ¹⁄₂ ” (343 mm) D 19 ³⁄₄ ” (502 mm) E 14 ³⁄₄ ” (375 mm) F 15” (381 mm) G 1 ¹⁄₂ ” (38 mm) H 4 ¹⁄₄ ” (108 mm) I 6 ³⁄₄ ” (171 mm) J 32 ¹⁄₂ ” (826 mm) K 8” (203 mm) Framing Dimensions L 31 ³⁄₄ ” (806 mm) M ...