Page 2 Version 1.0 March 1, 2000 We reserve the right to modify functions, technical data, standards, drawings and parameters. We have checked the contents of this document to ensure that they coincide with the described hardware and software. However, deviations cannot be completely ruled-out, so w...
Page 3 - Operating Instructions; detailed Operating Instructions; Operating Instruction.
Version 1.0 March 1, 2000 Page 3 Note: This Quick Startup Guide is not an autonomous document, but is intended to direct users tothe section in the Operating Instructions which are important for start-up. Thus, these brief instructions can only be completely valid when used in conjunction with the O...
Page 5 - Power Section Defintion
Version 1.0 March 1, 2000 Page 5 Section 1: Parameterization of Base Unit SIMOVERT MASTERDRIVES 6SE70 VC Vector Control 1.1 Power Section Defintion 1.2 Factory Reset 1.3 Basic Start-up 1.3.1 Volts/Hz without encoder feedback1.3.2 Volts/Hz with encoder feedback1.3.3 Vector Control without encoder fee...
Page 7 - Power Section Definition; Return to Parameter Menu
Version 1.0 March 1, 2000 Page 7 1.1 Power Section Definition Note: Power Section is pre-defined at the factory. Power SectionDefinition is required if a new board CUVC board is put into the drive orboards are switched between units with different ratings. Drive shouldbe defaulted and re-parameteriz...
Page 10 - DC
Page 10 Version 1.0 March 1, 2000 Frequency InverterDC-AC type DC 510V to 650V PWE Air Cooled PWE Water Cooled Order Number In[A] *1 4 6SE7016-1TA61 6.1 10 6SE7018-0TA61 8.0 12 6SE7021-0TA61 10.2 19 6SE7021-3TB61 13.2 26 6SE7021-8TB61 17.5 36 6SE7022-6TC61 25.5 43 6SE7023-4TC61 34.0 47 6SE7023-8TD61...
Page 17 - Basic Start-up without Motor Connected to Load; Select “Drive Settings”
Version 1.0 March 1, 2000 Page 17 1.3 Basic Start-up without Motor Connected to Load 1.3.1 Volts/Hz without Encoder P060 = 5 P071 = ? P095 = ? P097 = ? P101 = 460 P102 = xxx P104 = ? P105 = ? P060=5 Select “Drive Settings” P071 = Input Line Voltage AC-AC Converter=460VoltDC-AC Inverter = 620Volt P09...
Page 20 - Connect External Wiring as connection diagram.; Internal Connections
Page 20 Version 1.0 March 1, 2000 Connect External Wiring as connection diagram. Step 1: Dry set of contacts between terminals X101, pin#1 and pin#5 forLocal/Remote Mode Selection. Jumper if not required. Step 2: Dry set of contacts between terminals X101, pin#1 and pin#8 forCoast to Stop Selection....
Page 23 - Additional Connection for +15 Vdc Encoder.
Version 1.0 March 1, 2000 Page 23 Additional Connection for +15 Vdc Encoder. Step 10: Set Speed Reference to 20%. Step 11: Provide Start command. Note that if Signal A and Signal B arereversed, the motor will accelerate rapidly. Step 12: Connect the motor to the load, unless the plan is to change to...
Page 24 - Vector Control without Encoder Feedback; Wait
Page 24 Version 1.0 March 1, 2000 1.3.3 Vector Control without Encoder Feedback Note: Complete section 1.3.1 (Volts/Hz control without encoder feedback). P060 = 5 P100 = 3 P060 = 1 P115 = 4 Wait P060=5 Select “Drive Settings” P100=3 Selects Vector Controlwithout Encoder Feedback P060 = Return to Par...
Page 31 - Communication Board Configuration; SLB Telegram Failure Time; Automatic number of; Enter Number of Channels
Version 1.0 March 1, 2000 Page 31 1.5 Communication Board Configuration P060 = 4 CBx Inserted? P711 = ?toP721.1…5 = ? SLB Inserted? P740 = ? P741 = ? P742 = ? P743 = 0 P745 = ? P746 = ? P749.1…8 = ? CBP Inserted? P918.1…2 = ? P060 = 1 Select “Board Configuration”Menu Parameterize CBx BoardsSee Funct...
Page 33 - Power Section Defintion
Version 1.0 March 1, 2000 Page 33 Section 2: Parameterization of a Rectifer Unit SIMOVERT MASTERDRIVES 6SE70 VC Vector Control 2.0 Power Section Defintion 2.1 Factory Reset Basic Start-up2.2 Rectifier or Regen without auto-transformer2.3 Regen with auto-transformer
Page 35 - Power Section Definition
Version 1.0 March 1, 2000 Page 35 2.0 Power Section Definition Note: Power Section is pre-defined at the factory. Power SectionDefinition is required if a new board CUR board is put into the drive orboards are switched between units with different ratings. CUR cards willexist Regen Rectifiers and La...
Page 36 - Rated DC Output Current in Amps In[A]; PWE
Page 36 Version 1.0 March 1, 2000 Unit ListP070: Parameter Value (PWE) P075: Rated DC Output Current in Amps In[A] Large Common RectifierAC-DC type3 AC 380V to 460V PWE Order Number In[A 103 6SE7038-2EH85-0AA0 821.0 105 6SE7041-0EH85-0AA0 1023.0 109 6SE7041-3EK85-0AA0 1333.0 118 6SE7041-8EK85-0AA0 1...
Page 46 - P571=0 Selects Autotransformer
Page 46 Version 1.0 March 1, 2000 P571 = 0 P318 = 95 P052 = 21 P052 = 0 P571=0 Selects Autotransformer P318 = 95% Selects percentage of nominalDC BUS voltage. In cases wherethe input line voltage isdependable a setting of 100% ispermissible. With DC BUS connected to theCOMMON DC BUS of the system, s...
Page 51 - Select Trigger Channel
Version 1.0 March 1, 2000 Page 51 A D C B Select Record Settings inthe Lower Left Corner Select Desired Channelsto Record Set the Record Intervaland Pre-trigger Select Trigger Channel To Trigger With a Binector, Select:Trigger Channel = K431Trigger Condition “=” “1 Hex” K431 is the output of a Binec...
Page 52 - Zoom X 2; is
Page 52 Version 1.0 March 1, 2000 B A C D Select “Function BlockGrafics” from theParameter Menu Bar Select FunctionNumber 289 Zoom X 2 (with right Mouse click) Set Trigger Binector inU076.01 (i.e. U076.01 = 18 Din5) Activate BlockU952.89 = 4 A C B D K431 can now be used totrigger the Trace functionw...
Page 53 - Observe Status Message
Version 1.0 March 1, 2000 Page 53 Go to the Trace Window (Diagnostics Menu – Trace) Verify Record Settings Start Trace Trigger Trace Observe Status Message A D C B A C D B
Page 54 - Select Data Trace; to
Page 54 Version 1.0 March 1, 2000 A B C Select Data Trace A Click Data Set tomake it Active ScaleVertical Axis B Click and Dragscale to shift it upand down. Y ▲ & Y ▼ to change Scale ScaleHorizontal Axis C Click and drag “T”marker to shiftHorizontal Scale. Move “[ ]” tochange scale Note: Backgro...
Page 57 - Conditions that would merit re-tuning the drive; If the carrier frequency of P340 is adjusted in multiples that re-
Version 1.0 March 1, 2000 Page 57 4.0 Conditions that would merit re-tuning the drive Hardware additions made to the drive, such as an output reactor or adv/dt filter. Physical changes to the process, such as the motor being changed(even if the it is an identical motor, bearing changes and couplingc...