Table of Contents:

  • Page 2 – Defrost Lockout Feature; Setting The Clock; Hot Food Holding Cabinet Operation
  • Page 3 – Hot Food Holding Cabinet Operation (continued); Important Alarm Events
  • Page 4 – Before making contact, please make sure you have model; Amp Plate; You will be required to register for a login name and pass code; Local Authorized Service Agent; Contact Us Direct; Quality Refrigeration; raulsen
Loading the manual

NOTE:

Some models (model numbers

beginning with “UR” and single section
dual-temps) require provision of a bot-
tom mounted condensate evaporator.
Follow instructions provided with part,
along with this for installation.

II. Operation:

Most Traulsen equipment is plug and play, such as G Series & most Com-
pacts. However, once power is supplied to the unit, some may require
simple steps to get started using your Traulsen equipment, such as the:

R & A Series/TE Series/TU Series/TS Series Cabinets

Although fully operational the control will flash the cabinet temperature
alternatively with the message ELE LOS (power loss). Press the alarm
cancel button to cancel this message.

R & A Series Control TE/TU/TS Series Control

Hot Food Holding Cabinets

Are shipped in the Off position. To begin use, first press the ON/OFF
button , and then adjust to the desired operating temperature using
the UP/DOWN buttons.

Hot Food Control

G Series/Compact Cabinets

Are fully operational and no action is required to start. Please note, most
compacts are equipped with a electromechanical control.

Compact Cabinets (electromechanical)

The temperature is set at the factory but local conditions may neces-
sitate slight adjustment. The temperature control is located in the front
of the evaporator housing. To adjust, turn the adjustment screw with
a screwdriver a small amount at a time; turning clockwise lowers the
temperature. An

“OFF”

position is fully counterclockwise and inter-

rupts power to the compressor and condenser fan only, not the entire
refrigerator.

I. RECEIPT & SUPPORT INSTALLATION:

You should carefully inspect your Traulsen unit for damage during delivery.
If damage is detected, you should save all the crating materials and make
note on the carrier’s Bill Of Lading describing this. A freight claim should
be filed immediately.
After uncrating the unit, select a level location for final placement. Install
the legs or casters as shown below or, in the case of roll-in and roll-thru
models, these must be sealed to the floor in accordance with local health
codes.

R & A Series/G Series Supports (“Stem” type legs)

TE/TU/TS Series Supports

Compacts Supports (“Stem” type legs & casters)

All models (except undercounters) should be installed to allow at least 12”
of clear space above the unit. In all cases the louvers must be free of any
obstruction which could prevent proper air-flow.
Most units are supplied with a cord and plug, which can simply be
plugged into a dedicated appropriately sized outlet. For those requiring
hard-wiring directly to the power supply, this should be done by only a
qualified electrician.

Instructions for the installation, use & care of:

R & A Series
G Series
Compact Undercounter & Prep-Table
TE Series/TU Series/TS Series

Quality Refrigeration

OWNER’S MANUAL

TR35924 P/N 375-60293-00 (rev. 3-11)

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Defrost Lockout Feature; Setting The Clock; Hot Food Holding Cabinet Operation

III. Control Basics:Customer Access To adjust any of the control’s operating features, enter the customer access code. Use the code 0, A, 1 combined with the following: Press the SET button. The display will read CUS (Customer Access). Press the SET but- ton. The display will show three zeros with t...

Page 3 - Hot Food Holding Cabinet Operation (continued); Important Alarm Events

Hot Food Holding Cabinet Operation (continued) Turning the unit OFF/ON: After the temperature has been set, the customer can continuously turn the unit OFF and then back ON to the same temperature. To turn the unit on or off press the ON/OFF button . Temperature Adjustment: Press the SET button SET ...

Page 4 - Before making contact, please make sure you have model; Amp Plate; You will be required to register for a login name and pass code; Local Authorized Service Agent; Contact Us Direct; Quality Refrigeration; raulsen

VIII. TROUBLE SHOOTING: IX. CONTACT/WARRANTY INFORMATION: NOTE: Before making contact, please make sure you have model and serial number of unit available. Amp plate with information needed is located on the unit. Amp Plate NOTE: You will be required to register for a login name and pass code to acc...

Other Traulsen Models