  • Page 2 – Contents; ADOPTION OF NEW REFRIGERANT
  • Page 3 – Warning Indications on the Air Conditioner Unit; PRECAUTIONS FOR SAFETY; WARNING; General; Installation
  • Page 4 – CAUTION
  • Page 5 – ACCESSORY PARTS; Required Tools and Cautions on handling; Explanation of symbols
  • Page 6 – SELECTION OF INSTALLATION PLACE; Avoid the following places:; Installation space; NOTE
  • Page 7 – CARRYING IN THE OUTDOOR UNIT
  • Page 8 – Weight centre and weight; Weight centre of an outdoor unit; INSTALLATION OF THE OUTDOOR UNIT; REQUIREMENT
  • Page 9 – Liquid piping
  • Page 10 – When drawing pipes downward; REFRIGERANT PIPING; Connection of refrigerant pipe
  • Page 11 – Pipe connection method of valve at the gas side (Example)
  • Page 12 – Coupling size of brazed pipe; Selection of pipe size; Capacity code of indoor and outdoor units
  • Page 15 – System restriction; Airtightness test; Able to detect a serious leakage; Packed valve details
  • Page 16 – Vacuum drying
  • Page 17 – Adding refrigerant
  • Page 18 – Full opening of the valve; Heat insulation for pipe
  • Page 19 – Pipe holding bracket; When using the piping cover; ELECTRIC WIRING; Power supply specifications; Power wiring selection; Standard model
  • Page 20 – High efficiency model; Specifications for communication wiring; Design of communication wiring; Summary of communication wiring
  • Page 21 – Group control through a Remote Controller; Connection of power wires and communication wires
  • Page 22 – Power supply wire connection; Communication wire connection; Screw size and tightening torque
  • Page 23 – Regulation of high frequency wave; ADDRESS SETTING; Automatic address setting
  • Page 24 – Address setting procedure 1; Address setting procedure 2
  • Page 26 – Manual address setting using the remote controller
  • Page 27 – Confirming the numbers and; To see the indoor unit address of an
  • Page 28 – To select another system address; To change an indoor unit address using a
  • Page 30 – TEST RUN; Before test run; Methods of test run; When executing a test run using a; When executing a test run using
  • Page 32 – TROUBLESHOOTING; -Segment display and check code; Check code (indicated on the 7-segment display on the outdoor unit)
  • Page 33 – MACHINE CARD AND LOGBOOK; Machine card; Describe the following items on the machine card:; Logbook; Describe the following items on the logbook:
  • Page 34 – WARNINGS ON REFRIGERANT LEAKAGE; Check of Concentration Limit; Important
Loading the manual

AIR CONDITIONER (MULTI TYPE)

Outdoor Unit

Model name:

<Heat Pump Model>

MMY-MAP0804HT8-E
MMY-MAP1004HT8-E
MMY-MAP1204HT8-E
MMY-MAP1404HT8-E
MMY-MAP1604HT8-E

MMY-MAP0804HT8Z-E
MMY-MAP1004HT8Z-E
MMY-MAP1204HT8Z-E
MMY-MAP1404HT8Z-E
MMY-MAP1604HT8Z-E

MMY-MAP0804HT8ZG-E
MMY-MAP1004HT8ZG-E
MMY-MAP1204HT8ZG-E
MMY-MAP1404HT8ZG-E
MMY-MAP1604HT8ZG-E

Installation manual

English

Installation manual

<Cooling Only Model>

MMY-MAP0804T8-E
MMY-MAP1004T8-E
MMY-MAP1204T8-E
MMY-MAP1404T8-E
MMY-MAP1604T8-E

MMY-MAP0804T8Z-E
MMY-MAP1004T8Z-E
MMY-MAP1204T8Z-E
MMY-MAP1404T8Z-E
MMY-MAP1604T8Z-E

MMY-MAP0804T8ZG-E
MMY-MAP1004T8ZG-E
MMY-MAP1204T8ZG-E
MMY-MAP1404T8ZG-E
MMY-MAP1604T8ZG-E

For commercial use

Not accessible to the general public

Vente interdite au grand public

Kein öffentlicher Zugang

Non accessibile a clienti generici

No destinado al público en general

Não acessível ao público em geral

Niet geschikt voor huishoudelijk gebruik

Μη

προσβάσιμο

από

το

γενικό

κοινό

Недоступен

для

посторонних

Genel eri

ş

ime aç

ı

k de

ğ

ildir

+00EH99871699_01EN.book Page 1 Thursday, August 26, 2010 4:41 PM

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Contents; ADOPTION OF NEW REFRIGERANT

– 1 – SMMS-i Installation Manual SMMS-i Installation Manual Original instruction Contents 1 PRECAUTIONS FOR SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2 ACCESSORY PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

Page 3 - Warning Indications on the Air Conditioner Unit; PRECAUTIONS FOR SAFETY; WARNING; General; Installation

– 2 – SMMS-i Installation Manual EN SMMS-i Installation Manual „ Warning Indications on the Air Conditioner Unit Work undertaken Protective gear worn All types of work Protective gloves ‘Safety’ working clothing Electrical-related work Gloves to provide protection for electricians and from heat Insu...

Page 4 - CAUTION

– 3 – SMMS-i Installation Manual SMMS-i Installation Manual Refrigerant piping • Install the refrigerant pipe securely during the installation work before operating the air conditioner. If the compressor is operated with the valve open and without refrigerant pipe, the compressor sucks air and the r...