Toshiba LF654 - Manual
Toshiba LF654 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – The test results were obtained and demonstrated at; Model LF654 Detector; Note: Before shipping from the manufacturer, each detector; See Table 4 for optional materials and other
- Page 3 – Note: DI cannot be used with the Modbus communication.; DO1 cannot be used if Modbus; The same and simultaneous
- Page 5 – Installation; Dimensions
- Page 7 – Figure 5. Separate type detectors LF654
- Page 8 – Figure 6. Separate type detectors LF654
- Page 9 – Figure 7. Separate type converter LF622 and LF622F; External Connections; Use the appropriate switch rating as shown below:
- Page 11 – Figure 10. Electrical Conductivity and Cable; Meter Size; To select the meter size:; Make sure the full-scale flow rate used for the final; Table 2. Flow Rate and Flow velocity; Size
- Page 12 – Table 3. Flow Rate and Flow velocity; About establishment environment; Hazardous location certification type
- Page 13 – Table 4. Specification Code (Flange type detector LF654 Series)
- Page 14 – Table 5. Specification Code for converters; Refer to Table 6 for more details.; Table6. Communication functions and output selection table; Specifications are subject to change without notice.
TIC-LF654L
Introduction
The electromagnetic flowmeter uses Faraday’s Law of
electromagnetic induction to measure the process flow.
The device consists of two units: a detector, through
which the fluid to be measured flows and in which
low-level signals proportional to flow rates are
obtained; and a converter, which supplies excitation
current to the detector, and amplifies the signals from
the detector and then processes and converts the signals
into the 4–20 mAdc current signal or communication
signal. The meter features a
Mount-Anywhere
magnetic field distribution technology, the meter is
highly immune to upstream flow disturbances.
Combined with a multi-functional converter LF620
(combined type) or LF622 (separate type) equipped
with its patented
Noise-Sentry
original noise-
suppression circuit and advanced algorithms. The
LF654 has a very high tolerance to noise, giving the unit
a very stable output even for slurry fluid measurement.
IR (Infrared) switches enable parameter setting of the
converter without removing the cover. Flow direction
can be set in either way, and its unique 128 x 128 dot
matrix LCD display allows the LCD to be rotated
electronically to 90, 180 and 270 degrees without
opening the cover.
* HART protocol (Highway Addressable Remote Transducer) is
a communication protocol for industrial sensors recommended
by the HCF (HART Communication Foundation).
** DevComm2000 Smart Device Communicator available
through TIC for performing HART device configurations on
PC or laptop .
* PROFIBUS is the communications protocol for factory and
process automation that the PROFIBUS Organization
recommends. Instead of analog control with a conventional
analog signal (4-20 mA), it is fieldbus which digitizes all
signals. Flowmeters support PROFIBUS-PA.
* Modbus is the communication protocol that Modicon Inc.
developed. Physical layer is RS485.
C om b ine d t yp e
Se par at e t yp e
Figure1. Configuration
LF654/LF620F LF654 LF622F
Figure2. LF654 Mount-Anywhere Series
Flowmeters
Specifications
Overall Specifications
Measurement range in terms of flow velocity:
0 –1.0 ft/s to 0 – 39.4ft/s (0 – 0.3 m/s to 0 –12 m/s).
0 – 0.3 ft/s to 0 – 1.0 ft/s (0 – 0.1 m/s to 0 – 0.3 m/s)
range is available optionally.
Accuracy:
< 1/2" to 18" ( 15mm to 450mm) >
±0.2 % of Rate
*
* This pulse output error result is established under standard
operating conditions at Toshiba admitted flow calibration
facility. (NIST Traceable)
* Individual meter measurement error may vary up to ±0.5% of
Rate at 1.64 ft/s (0.5m/s) or more and ±0.3% of rate ±0.039
inch/s (1mm/s) at 1.64 ft/s or less.
* Current output: plus ± 8µA (0.05% of span.)
* Refer to individual calibration data for each individual meter's
measurement error.
Field Intelligent Device – Mount Anywhere Series - Flanged
Electromagnetic Flowmeter
LF654 /LF620
LF654 /LF622
1/2" to 18" (15 to 450 mm)
Certification
No. Z01207
For PU and
HR lined flowmeter
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
TIC-LF654L 2 Fluid conductivity: 3µS/cm minimum Fluid temperature: -4 to 248 °F (-20 to +120 °C): PFA lined flowmeter -4 to 140 °F (-20 to +60 °C): Polyurethane lined flowmeter 23 to 176 °F (- 5to +80 °C): Hard Rubber lined flowmeter Ambient temperature: -40 to 140 °F (-40 to +60 °C): PFA lined flow...
TIC-LF654L 3 Model LF620 and LF622 converters Input signals Analog signal — the voltage signal from detector, proportional to process flow rate (for LF622 separate type converter). Digital input DI Signal type: 20 to 30Vdc voltage signal Input resistance: 2.7k Number of inputs: one point Note: D...
TIC-LF654L 5 Installation Dimensions Note1: Eye bolts are provided at the top for flowmeters sized 8" (200mm) or above, and further, a roll-prevention base is provided for flowmeters sized 10" (250mm) or larger. Note2: Cable glands are not provided for LF654 of cFMus approved type. Refer t...