Toshiba LF654 - Manual

Toshiba LF654

Toshiba LF654 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
Page: / 14

Table of Contents:

  • Page 2 – The test results were obtained and demonstrated at; Model LF654 Detector; Note: Before shipping from the manufacturer, each detector; See Table 4 for optional materials and other
  • Page 3 – Note: DI cannot be used with the Modbus communication.; DO1 cannot be used if Modbus; The same and simultaneous
  • Page 5 – Installation; Dimensions
  • Page 7 – Figure 5. Separate type detectors LF654
  • Page 8 – Figure 6. Separate type detectors LF654
  • Page 9 – Figure 7. Separate type converter LF622 and LF622F; External Connections; Use the appropriate switch rating as shown below:
  • Page 11 – Figure 10. Electrical Conductivity and Cable; Meter Size; To select the meter size:; Make sure the full-scale flow rate used for the final; Table 2. Flow Rate and Flow velocity; Size
  • Page 12 – Table 3. Flow Rate and Flow velocity; About establishment environment; Hazardous location certification type
  • Page 13 – Table 4. Specification Code (Flange type detector LF654 Series)
  • Page 14 – Table 5. Specification Code for converters; Refer to Table 6 for more details.; Table6. Communication functions and output selection table; Specifications are subject to change without notice.
Loading the manual

TIC-LF654L

Introduction

The electromagnetic flowmeter uses Faraday’s Law of

electromagnetic induction to measure the process flow.

The device consists of two units: a detector, through

which the fluid to be measured flows and in which

low-level signals proportional to flow rates are

obtained; and a converter, which supplies excitation

current to the detector, and amplifies the signals from

the detector and then processes and converts the signals

into the 4–20 mAdc current signal or communication

signal. The meter features a

Mount-Anywhere

magnetic field distribution technology, the meter is

highly immune to upstream flow disturbances.

Combined with a multi-functional converter LF620

(combined type) or LF622 (separate type) equipped

with its patented

Noise-Sentry

original noise-

suppression circuit and advanced algorithms. The

LF654 has a very high tolerance to noise, giving the unit

a very stable output even for slurry fluid measurement.

IR (Infrared) switches enable parameter setting of the

converter without removing the cover. Flow direction

can be set in either way, and its unique 128 x 128 dot

matrix LCD display allows the LCD to be rotated

electronically to 90, 180 and 270 degrees without

opening the cover.

* HART protocol (Highway Addressable Remote Transducer) is

a communication protocol for industrial sensors recommended
by the HCF (HART Communication Foundation).

** DevComm2000 Smart Device Communicator available

through TIC for performing HART device configurations on
PC or laptop .

* PROFIBUS is the communications protocol for factory and

process automation that the PROFIBUS Organization
recommends. Instead of analog control with a conventional
analog signal (4-20 mA), it is fieldbus which digitizes all
signals. Flowmeters support PROFIBUS-PA.

* Modbus is the communication protocol that Modicon Inc.

developed. Physical layer is RS485.

C om b ine d t yp e

Se par at e t yp e

Figure1. Configuration

LF654/LF620F LF654 LF622F

Figure2. LF654 Mount-Anywhere Series

Flowmeters

Specifications

Overall Specifications

Measurement range in terms of flow velocity:

0 –1.0 ft/s to 0 – 39.4ft/s (0 – 0.3 m/s to 0 –12 m/s).

0 – 0.3 ft/s to 0 – 1.0 ft/s (0 – 0.1 m/s to 0 – 0.3 m/s)

range is available optionally.

Accuracy:
< 1/2" to 18" ( 15mm to 450mm) >

±0.2 % of Rate

*

* This pulse output error result is established under standard

operating conditions at Toshiba admitted flow calibration
facility. (NIST Traceable)

* Individual meter measurement error may vary up to ±0.5% of

Rate at 1.64 ft/s (0.5m/s) or more and ±0.3% of rate ±0.039
inch/s (1mm/s) at 1.64 ft/s or less.

* Current output: plus ± 8µA (0.05% of span.)
* Refer to individual calibration data for each individual meter's

measurement error.

Field Intelligent Device – Mount Anywhere Series - Flanged

Electromagnetic Flowmeter

LF654 /LF620
LF654 /LF622

1/2" to 18" (15 to 450 mm)

Certification
No. Z01207

For PU and

HR lined flowmeter

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - The test results were obtained and demonstrated at; Model LF654 Detector; Note: Before shipping from the manufacturer, each detector; See Table 4 for optional materials and other

TIC-LF654L 2 Fluid conductivity: 3µS/cm minimum Fluid temperature: -4 to 248 °F (-20 to +120 °C): PFA lined flowmeter -4 to 140 °F (-20 to +60 °C): Polyurethane lined flowmeter 23 to 176 °F (- 5to +80 °C): Hard Rubber lined flowmeter Ambient temperature: -40 to 140 °F (-40 to +60 °C): PFA lined flow...

Page 3 - Note: DI cannot be used with the Modbus communication.; DO1 cannot be used if Modbus; The same and simultaneous

TIC-LF654L 3  Model LF620 and LF622 converters Input signals Analog signal — the voltage signal from detector, proportional to process flow rate (for LF622 separate type converter). Digital input DI Signal type: 20 to 30Vdc voltage signal Input resistance: 2.7k  Number of inputs: one point Note: D...

Page 5 - Installation; Dimensions

TIC-LF654L 5 Installation  Dimensions Note1: Eye bolts are provided at the top for flowmeters sized 8" (200mm) or above, and further, a roll-prevention base is provided for flowmeters sized 10" (250mm) or larger. Note2: Cable glands are not provided for LF654 of cFMus approved type. Refer t...

Other Toshiba Models