Toro Plus Series Satellite - Manual

Toro Plus Series Satellite

Toro Plus Series Satellite – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
Page: / 19

Table of Contents:

  • Page 2 – CONTROLLER COMPONENTS
  • Page 3 – Selecting Control Options; To change the DIP switch positions:; mechanism can remain connected for this procedure).; Reinstall the timing mechanism and switch on the power.; OFF
  • Page 5 – Repeat steps 4–8 for each station as required.
  • Page 6 – Repeat steps 5 – 10 for all desired start times for this program.
  • Page 7 – Set Active Day Watering Schedules; Note the following programming characteristics:; To Set a Calendar schedule:; Repeat steps 3 – 9 for all programs requiring a Calendar
  • Page 8 – Interval Schedule; To set an Interval schedule:; Repeat steps 3 – 10 for each program requiring an Interval
  • Page 9 – Set Program Repeat and Soak; Repeat steps 2 – 10 for all programs as required.
  • Page 10 – Cycle Mode
  • Page 11 – Syringe Mode; To syringe all stations from 1 – 30 minutes:
  • Page 12 – Repeat steps 2 – 5 to start up to five additional Stations. If the
  • Page 13 – Set Satellite Address; Address indicator The displays show the; Set Percent Adjust; Repeat steps 2 – 5 for all programs as required.
  • Page 14 – Self Test; To perform the self test:; Initialization; To perform an initialization:
  • Page 15 – Radio Calibration Test; To Perform Radio Calibration Test:; Link Monitor; Press and hold down the
  • Page 16 – Troubleshooting; carefully lift panel up.; Problem; WARNING
  • Page 17 – Switch power supply Off
  • Page 18 – Program Data Reference Form; Station Location
  • Page 19 – U s e r ' s G u i d e; Network LTC; Series Satellite
Loading the manual
Page 1

Controller Components ................................................. 2

Selecting Control Options ............................................ 3

Before Programming the Controller… ..........................4

About The Controller’s Memory ................................... 4

Set Satellite Operating Mode ........................................ 4

Set Current Time and Day ............................................. 5

Set Station Run Times ................................................... 5

Set Program Start Time(s) ............................................ 6

Set Active Day Watering Schedules ............................ 7

• Calendar Schedule .................................................... 7

• Interval Schedule ...................................................... 8

Set Program Repeat and Soak ..................................... 9

Program Operation Pause and Cancel ...................... 10

Manual Control Operations ...................................10- 12

Cycle Mode ................................................................... 10

Syringe Mode ............................................................... 11

Multi-Manual Mode ...................................................... 12

Set Satellite Address ................................................... 13

Set Percent Adjust ....................................................... 13

Reviewing Program Information ................................ 14

Special Functions ................................................... 14-15

Self Test ........................................................................ 14

Initialization .................................................................. 14

Radio Calibration Test ................................................. 15

Link Monitor ................................................................ 15

Troubleshooting .......................................................... 16

Lithium Battery Installation (Optional)....................... 16

Manual Output Switch Operation ............................... 17

Power Indicator Lamps ............................................... 17

Program Data Reference Form ....................................18

1

Table of Contents

Power Specifications

Line Voltage: 115/230 V a.c. 50/60 Hz (switchable),
130 VA (100W)

Current Draw (no load): 0.21A @ 115 V a.c., 60 Hz, 0.10A
@ 230V, 50 Hz

Current Draw (maximum load): 0.90A @ 115 V a.c, 60 Hz,
0.42A @ 230 V a.c, 50 Hz

Secondary Voltage Output: 24 V a.c., 3.2A (77 VA)

Maximum Load Per Station Output: 0.75A (18 VA)

Maximum Load Per Pump/Master Valve Output:
0.75A (18 VA)

Hardware Features

Plastic or Painted Stainless Steel Cabinetry

Front, Back and Top Locking Covers

Removable Station Output and Common/Pump Modules

Modular Station Output:
16 to 64 stations in 8-station increments

Fuses and Circuit Breakers

Power Supply:

1.5A On/Off Switch/Circuit Breaker – Main Power Input

3.2A Fuse (Slow-Blow) – Field Output

4A Circuit Breaker – Control Functions

Communication Modem (optional): 3/4A (Fast-Blow)

Pump/Common & Communication Surge Protection
Module (optional): 1/2A (Fast-Blow)

Electromagnetic Compatibility

Domestic: This equipment has been tested and found to
comply with the limits for a FCC Class A digital device,
pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful
interference when the equipment is operated in a
commercial environment. The equipment generates, uses,
and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction
manual, may cause harmful interference to the radio
communications. Operation in a residential area is likely to
cause harmful interference in which case the user will be
required to correct the interference at his own expense.

International: This is a CISPR 22 Class A product. In a
domestic environment, this product may cause radio
interference, in which case the user may be required to
take adequate measures.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Was this manual helpful?

About this manual

Brand
Toro
Model
Plus Series Satellite
Document type
Manual
Language(s)
English
Pages
19
File size
407.6 KB
Format
PDF

Summary

Page 2 - CONTROLLER COMPONENTS

CONTROLLER COMPONENTS 2 Address % Adjust Time/Day Week 1 Central Stand Alone Off Cycle Syringe MultiManual Start Times Active Days Run Times ENTER START EXIT STOP 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Week 2 R LTC T M Tu Programs Plus 1. Control Panel Assembly 2. Pump/Common Output Module 3. Power Indica...

Page 3 - Selecting Control Options; To change the DIP switch positions:; mechanism can remain connected for this procedure).; Reinstall the timing mechanism and switch on the power.; OFF

Selecting Control Options A set of eight DIP switches, located beneath the upper left corner of the control panel (as illustrated below)is provided for the selection of optional control characteristics. Power to the controller must be turned Offand the control panel removed from the cabinet in order...

Page 5 - Repeat steps 4–8 for each station as required.

Set Current Time and Day Synchronizing the controller's clock with the current time and day is an important first step in the programmingprocedure. The timed events for all watering programs (when the satellite is in the Satellite Mode) are based onthe settings you will make here. Use the following ...

Ask a question

Up to 3 photos. Max 5 MB each. Formats: JPG, JPEG, PNG, WebP.