Page 2 - Complete this page for quick reference when service is required:; Date of Installation:; Information found on the data label:; Voltage; 998 Carrier Commercial Refrigeration, Inc.; Taylor Company; a division of Carrier Commercial Refrigeration, Inc.
Complete this page for quick reference when service is required: Taylor Distributor: Address: Phone: Service: Parts: Date of Installation: Information found on the data label: Model Number: Serial Number: Electrical Specs: Voltage Cycle Phase Maximum Fuse Size: A Minimum Wire Ampacity: A E 1998 Carr...
Page 3 - Table of Contents
Model 432 Table of Contents Table of Contents Section 1 To the Installer 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installer Safety 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Site P...
Page 4 - Table of Contents - Page 2; civil and criminal penalties.
Model 432 Table of Contents Table of Contents - Page 2 Disassembly 19 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Brush Cleaning 20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
Page 5 - Installer Safety
1 Model 432 To the Installer 131202 Section 1 To the Installer The following information has been included in the manual as safety and regulatory guidelines. For complete installation instructions, please see the Installation Checklist. Installer Safety In all areas of the world, equipment should be...
Page 6 - Electrical Connections; Beater Rotation
2 To the Installer Model 432 131202 Electrical Connections This unit must be plugged into a properly grounded receptacle. The cord and plug must be sized for 20 Amp usage. The voltage specifications are 208- 230/60/1. Follow specifications listed on your data plate. FOLLOW YOUR LOCAL ELECTRICAL CODE...
Page 7 - To the Installer; Refrigerant
3 Model 432 To the Installer 131202 Refrigerant In consideration of our environment, Taylor uses only HFC refrigerants. The HFC refrigerant used in this unit is R404A. This refrigerant is generally considered non-toxic and non-flammable, with an Ozone Depleting Potential (ODP) of zero (0).However, a...
Page 8 - Compressor Warranty Disclaimer
4 To the Operator Model 432 131202 Section 2 To the Operator The freezer you have purchased has been carefully engineered and manufactured to give you dependable operation. The Taylor Model 432, when properly operated and cared for, will produce a consistent quality product. Like all mechanical prod...
Page 11 - Operator Parts Identification; Section 4; Figure 1
7 Model 432 Operator Parts Identification Section 4 Operator Parts Identification Model 432 Figure 1 ITEM DESCRIPTION PART NO. 1 COVER A.-HOPPER X52452 2 PANEL-REAR 052363 3 PANEL-SIDE-RIGHT-LOUVERED 052527 4 PANEL-FRONT-LOWER 052361 5 GASKET-BASE PAN 052377 6 TRAY A.-DRIP X46848 7 SHIELD-SPLASH 046...
Page 12 - Beater Door Assembly; Figure 2
8 Operator Parts Identification Model 432 120730 Beater Door Assembly Figure 2
Page 13 - Beater Door Assembly Parts Identification
9 Model 432 Operator Parts Identification 120730 Beater Door Assembly Parts Identification ITEM DESCRIPTION PART NO. 1 DOOR A. - PARTIAL X39248 2 HANDLE A. DRAW X47384 3 NUT-STUD 029880 4 BUSTER - ICE 047735 5 O-RING - 1" OD X .139 W 032504 6 VALVE DRAW - SLUSH - ICEBUSTER 047734 7 VALVE A. - HA...
Page 14 - Accessories; Figure 3
10 Operator Parts Identification Model 432 140814 Accessories Figure 3 ITEM DESCRIPTION PART NO. 1 KIT A.- TUNE UP X39969 2 BRUSH- MIX PUMP 3” X 7” 023316 3 PAIL- 10 QT. 013163 4 BRUSH- DOUBLE ENDED 013072 5 BRUSH- REAR BEARING 1 X 2 013071 ITEM DESCRIPTION PART NO. 6 BRUSH- DRAW VALVE 1- 1/2X3 0147...
Page 15 - Important: To the Operator; Section 5; Figure 4; Item
11 Model 432 Important: To the Operator Section 5 Important: To the Operator Figure 4 Item Description 1 Switch- Toggle - 3 PDT 2 Switch- Push Button - SPST 3 Switch- Toggle- SPST - 3/4 HP/250 V 4 Light- Amber- Rect. - 12 VDC - MIX OUT 5 Light- Amber- Rect. - 12 VDC - ADD MIX 6 Viscosity Adjustment ...
Page 17 - Operating Procedures; Section 6; Assembly; MAKE SURE THE POWER SWITCH IS IN
13 Model 432 Operating Procedures Section 6 Operating Procedures The Model 432 freezer is designed to produce shake or slush product at the desired thickness. This unit has a 4 quart freezing cylinder. We begin our instructions at the point where we enter the store in the morning and find the parts ...
Page 21 - Sanitizing; Repeat these steps for the other side of the unit.
17 Model 432 Operating Procedures 140814 Sanitizing Step 1 Prepare an approved 100 PPM sanitizing solution (examples: 2- 1/2 gal. [9.5 liters] of Kay- 5 R or 2 gal. [7.6 liters] of Stera- Sheen R ). USE WARM WATER AND FOLLOW THE MANUFACTURER’S SPECIFICATIONS. Step 2 Pour the sanitizing solution into...
Page 22 - Priming; Closing Procedure
18 Operating Procedures Model 432 Priming Step 1 With a pail beneath the door spout, move the draw handle to the right. Pour two gallons (7.6 liters) of FRESH mix into the hopper and allow it to flow into the freezing cylinder. This will force out any remaining sanitizing solution. When full strengt...
Page 23 - Rinsing
19 Model 432 Operating Procedures 140814 Step 3 If local health codes permit the use of rerun , place a sanitized, NSF approved stainless steel rerun container beneath the door spout. Place the power switch in the “WASH” position and move the draw handle to the right. When all the product stops flow...
Page 24 - Brush Cleaning
20 Operating Procedures Model 432 Brush Cleaning Step 1 Prepare a sink with a cleaning solution (examples: Kay- 5 R or Stera- Sheen R ). USE WARM WATER AND FOLLOW THE MANUFACTURER’S SPECIFIC- ATIONS. (If another approved cleaner is used, dilute according to label instructions. IMPORTANT: Follow the ...
Page 25 - During Cleaning and Sanitizing:; Troubleshooting Bacterial Count:
21 Model 432 Important: Operator Checklist 080118 Section 7 Important: Operator Checklist During Cleaning and Sanitizing: ALWAYS FOLLOW LOCAL HEALTH CODES. Cleaning and sanitizing schedules are governed by federal, state, or local regulatory agencies, and must be followed accordingly. If the unit ha...
Page 26 - Important: Operator Checklist; Winter Storage
22 Important: Operator Checklist Model 432 Winter Storage If the place of business is to be closed during the winter months, it is important to protect the freezer by following certain precautions, particularly if the building is to be left unheated and subject to freezing conditions.Disconnect the ...
Page 27 - Troubleshooting Guide; Section 8; PROBLEM
23 Model 432 Troubleshooting Guide Section 8 Troubleshooting Guide PROBLEM PROBABLE CAUSE REMEDY PAGE REF. 1. No product being dispensed. a. Control switch is in the “OFF” position. a. Place control switch in the “AUTO” position. 18 b. Improper mixing of product. b. Carefully follow directions for m...
Page 30 - Limited Warranty on Equipment
26 Limited Warranty on Equipment Model 432 131202 Section 10 Limited Warranty on Equipment TAYLOR COMPANY LIMITED WARRANTY ON FREEZERS Taylor Company, a division of Carrier Commercial Refrigeration, Inc. (“Taylor”) is pleased to provide this limited warranty on new Taylor-branded freezer equipment a...
Page 32 - Limited Warranty on Parts; TAYLOR COMPANY LIMITED WARRANTY ON TAYLOR GENUINE PARTS; No warranty; LIMITED WARRANTY CONDITIONS; location in the unit of original installation.
28 Limited Warranty on Parts Model 432 131202 Section 11 Limited Warranty on Parts TAYLOR COMPANY LIMITED WARRANTY ON TAYLOR GENUINE PARTS Taylor Company, a division of Carrier Commercial Refrigeration, Inc. (“Taylor”) is pleased to provide this limited warranty on new Taylor genuine replacement com...
Page 34 - The owner; must
30 Limited Warranty on Parts Model 432 LIMITATION OF WARRANTY THIS LIMITED WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER WARRANTIES, CONDITIONS AND/OR REMEDIES UNDER THE LAW, INCLUDING ANY IMPLIED WARRANTIES OR CONDITIONS OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. THE ORIGINAL OWNER...
Page 35 - Parts List
Section 12 Parts List 31 + Available Separately Model 432 Parts List 080619 DE S CRI P T IO N P ART NUM BE R QTY . W ARR. CL AS S RE M ARKS PART S UP DA T E 432 S T ANDARD (043227F000 208- 230V 60HZ 1 PH) A/ C- BRI STO L -R 404A ACCUMULATOR- C OPPER 2" DI A 10" LG 047062 1 103 ARM- TORQUE- 4...