State Water Heaters SUF-130-300 - Manual
State Water Heaters SUF-130-300 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – FOREWORD; GAS VALVE PIPING
- Page 3 – DANGER; FEATURES; IMPORTANT; PERFORM THE INITIAL FIRING OF THE HEATER. AT THIS TIME; WATER TEMPERATURE CONTROL; TABLE OF CONTENTS
- Page 4 – Horizontal Sidewall Venting
- Page 5 – CAUTION; THE FOLLOWING PROCEDURE. IN ALL CASES, INPUT POWER; DISHWASHING MACHINE REQUIREMENT
- Page 6 – CIRCULATING PUMP; INSTALLATION INSTRUCTIONS; REQUIRED ABILITY; IN STAL L ATION OR S ERVIC E OF TH IS WATER H EATER; INSULATION BLANKETS; LOCATING THE HEATER; WARNING
- Page 7 – *ILLUSTRATION OF MINIMUM COMBUSTIBLE CLEARANCES
- Page 8 – as adopted by the Board and; VENTING; THE INSTRUCTIONS IN THIS SECTION ON VENTING MUST
- Page 11 – VENT PIPE TERMINATION; EXHAUST OR INTAKE WILL BE OBJECTIONABLE. THIS INCLUDES; DIRECT VENTING; WHEN THE UNIT IS TO BE SETUP AS A DIRECT VENT,; DIRECT VENT TERMINAL INSTALLATION; N E W I N S TA L L AT I O N S . T O P R E V E N T E X H A U S T I N G; FOLLOWING SPECIFICATIONS PERTAINING TO TERMINAL
- Page 12 – Vent terminals supplied with the heater must be used.; EXHAUST VENT TERMINAL; VERTICAL VENT TERMINAL INSTALLATION; SPECIFICATIONS PERTAINING TO TERMINAL LOCATION MUST; INSTALLATION SEQUENCE
- Page 13 – THE OPTIONAL INTAKE VENTING ARRANGEMENT AND THE; Table 2. VENT LENGTH TABLE
- Page 14 – VENT PIPE PREPARATION; . INITIAL PREPARATION; PRIMER; S A F E T Y P R E C A U T I O N : P R I M E R S A N D C E M E N T S A R E; CONTROLS AND SWITCHES; BLOWER PROVER SWITCH; NOTE: LOW GAS SWITCH IS LOCATED ON INLET SIDE OF GAS
- Page 15 – HOT SURFACE IGNITER; GAS PIPING; CONNECTION OF GAS PIPE
- Page 16 – SYSTEM CONNECTIONS
- Page 17 – WATER (POTABLE) HEATING AND SPACE HEATING; NEVER; HEATER WIRING; DO NOT ENERGIZE THE BRANCH CIRCUIT BEFORE THE
- Page 20 – Operating States; OPERATION; SEQUENCE OF OPERATION; ELECTRONIC CONTROL; Overview
- Page 21 – Adjusting the Operating Set Point; The
- Page 22 – Changing the Display Units; contrast of the LCD screen.; Fault and Warning Conditions; diagnostics information that can be used to correct the issue.; Example of a Warning:
- Page 25 – NEVER OPERATE THE HEATER WITHOUT FIRST BEING
- Page 26 – LIGHTING AND OPERATION INSTRUCTIONS; FOR YOUR SAFETY READ BEFORE OPERATING
- Page 27 – . FLOODING TO OR ABOVE THE LEVEL OF THE BURNER OR; GENERAL INFORMATION; drops; MAINTENANCE; KEEP APPLIANCE AREA CLEAR AND FREE FROM COMBUSTIBLE; GAS SUPPLY SPECIFICATIONS Nat. Gas LP Gas
- Page 28 – be performed at the same time.; LIME SCALE REMOVAL
- Page 29 – BEFORE MANUALLY OPERATING THE VALVE, MAKE SURE; VENT SYSTEM
- Page 30 – INSTALLATION DIAGRAMS; WITH OR WITHOUT BUILDING RECIRCULATION
- Page 31 – TWO TEMPERATURE - ONE HEATER HIGH TEMPERATURE
- Page 32 – FOR MULTIPLE HEATER INSTALLATION SEE MANIFOLD KIT; FLOW PREVENTER, CHECK VALVE OR WATER METER WITH; TEMPERATURES ARE NECESSARY TO OBTAIN ADEQUATE
- Page 35 – MULTIPLE UNIT INSTALLATIONS; Space for the venting system and unit servicing must be added.
- Page 36 – CHECKLIST AND SERVICE INFORMATION; BE SURE TO TURN OFF THE ELECTRICITY WHENEVER; FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN; L A B E L A L L W I R E S P R I O R TO D I S C O N N E C T I O N W H E N; BURNER OPERATIONAL PROBLEMS; heater is in the ON position.; WATER IS TOO HOT; • Transformers often hum.; WATER LEAKAGE IS SUSPECTED; TROUBLESHOOTING
- Page 37 – NOTE: ANY BYPASS OR ALTERATION OF THE UNITS SAFETIES; MOTOR WILL NOT RUN
- Page 38 – in rough ignition and/or noisy operation.; Do not reach into the burner housing or combustion chamber if the; NOISY BURNER OPERATION
- Page 40 – 00 TENNESSEE WALTZ PARKWAY
500 TENNESSEE WALTZ PARKWAY
ASHLAND CITY, TN 37015
PLACE THESE INSTRUCTIONS ADJACENT TO HEATER AND NOTIFY OWNER TO KEEP FOR FUTURE REFERENCE.
PRINTED 0307
97483-002
ULTRA FORCE
SUF-130- 300 AND 400
COMMERCIAL GAS WATER HEATER
GAS-FIRED POWER BURNER
FOR DOMESTIC HOT WATER
Thank you for buying this energy efficient water heater
from State Industries. We appreciate your confidence in
our products.
CAUTION
TEXT PRINTED OR OUTLINED IN RED CONTAINS
INFORMATION RELATIVE TO YOUR SAFETY. PLEASE
READ THOROUGHLY BEFORE INSTALLING AND USING
THIS APPLIANCE.
• INSTALLATION • OPERATION • SERVICE • MAINTENANCE • LIMITED WARRANTY
WARNING: If the information in these
instructions is not followed exactly, a fire
or explosion may result causing property
damage, personal injury or death.
– Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
– WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch;
d o n o t u s e a n y p h o n e i n y o u r
building.
• Immediately call your gas supplier
from a neighbor's phone. Follow
the gas supplier's instructions.
• If you cannot reach your gas supplier,
call the fire department.
– I n s t a l l a t i o n a n d s e r v i c e m u s t b e
performed by a qualified installer,
service agency or the gas supplier.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 These designs comply with the current edition of the American N a t i o n a l S t a n d a r d f o r G a s Wa t e r H e a t e r s , Vo l u m e I I I , ANSI Z21.10.3 / CSA 4.3 as an automatic circulating tank water heater, and automatic storage water heaters. Detailed installation diagrams are found...
3 DANGER THIS WATER HE ATER IS EQUIPPED WITH AN ADJUSTABLE THERMOSTAT TO CONTROL WATER TEMPER ATURE. HOT WAT E R T E M P E R AT U R ES R EQ U I R E D FO R AU TO M AT I C D I S H WA S H E R A N D L AU N D RY U S E C A N C AU S E S C A L D B U R N S R E S U LT I N G I N S E R I O U S P E R S O N A L I...
4 “AT A GLANCE” QUICK INSTALLATION TIPS Horizontal Sidewall Venting Vertical Roof top Venting