SPX 1000 - Manual

SPX 1000

SPX 1000 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
Page: / 32

Table of Contents:

  • Page 2 – Marley; Cooling Tower; Table of Contents
  • Page 4 – OUT; PLAN; NotE; Last number of model indicates number of cells. Change as
  • Page 5 – ENdwALL; Use this bulletin for preliminary layouts only.; Tower
  • Page 7 – FLAt BAsiN sEctioN
  • Page 11 – Use this bulletin for preliminary layouts only
  • Page 12 – Cooling Tower Energy
  • Page 13 – Enclosures; Marley Technical Report; External Influences on Cooling Tower Perfor-; CAUTION
  • Page 14 – Plans. The limiting overall dimensions
  • Page 15 – Under no circumstances should you allow the manufacturer to; Typical cooling tower performance curve.
  • Page 16 – If
  • Page 17 – Fan Deck and Fan Cylinder:; Diagonal Connector
  • Page 18 – Mechanical Equipment:
  • Page 19 – Louver
  • Page 20 – Hot Water Distribution System:
  • Page 21 – Cold Water Collection Basin
  • Page 22 – Specifications; Specification Value; Control Options; Add the following paragraph in
  • Page 23 – Fan Motor Variable Speed Drive:; Add the following paragraph in the
  • Page 24 – Marley Premium VFD System
  • Page 25 – Vibration Limit Switch:
  • Page 26 – Convenience and Safety Options; Add the following to the end of this
  • Page 27 – Oil Level Sight Glass:
  • Page 28 – Add the following at the end of this
  • Page 29 – Watertight Partitions Between Cells:; Replace the last sentence in this
Loading the manual

/

Marley Sigma 1000/1200

Cooling Tower

/

Engineering Data & Specifications

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Marley; Cooling Tower; Table of Contents

Marley / Sigma 1000/1200 Cooling Tower / Table of Contents Engineering Data 1000 Schematic 4 1000 Piping 5 1000 Support 6 1200 Schematic 8 1200 Piping 9 1200 Support 10 Energy Management 12 Environmental 13 Specifications / Base Base 14 Thermal Performance 15 Construction 16 Fan Deck and Fan Cylinde...

Page 4 - OUT; PLAN; NotE; Last number of model indicates number of cells. Change as

Marley / Sigma 1000 Cooling Tower / Engineering Data : Schematic 4 B H TOP OFFAN CYLINDER BASE OFTOWER COLUMNS TOP OFFAN DECK W OUT T O OUT OF TOWER 5" CL COL. A BAYS @ 4'-0 = L CL COL. CL COL. 5" C DIA. FAN PLAN ENdwALL ELEvAtioN NotE 1 Last number of model indicates number of cells. Change...

Page 5 - ENdwALL; Use this bulletin for preliminary layouts only.; Tower

Marley / Sigma 1000 Cooling Tower / Engineering Data : Piping 5 F MINIMUM CL INLET CL COL. C CL INLET D TYP. MULTI-CELL PIPING SHOWN WITH DASHED LINES IS BY OTHERS E FACE OF A DIA. INLET PIPING C L TOWER FAN C L TOWER FAN B DIA. FLOW CONTROL VALVE AND CROSS OVER PIPING PLAN G BASE OF TOWER COLUMNS C...