Page 3 - Qualified Personnel
Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to ...
Page 4 - Preface; Information on the documentation
Preface Information on the documentation At http://www.siemens.com/motioncontrol/docu information is available on the following topics: ● Ordering documentation Here you can find an up-to-date overview of publications ● Downloading documentation Links to more information for downloading files from S...
Page 5 - If you have any technical questions, please contact our hotline:; Questions about this documentation; A fax form is available in the appendix of this document.; Internet address for products
Preface Technical Support If you have any technical questions, please contact our hotline: Europe / Africa Phone +49 180 5050 222 Fax +49 180 5050 223 0.14 €/min. from German landlines (mobile call charges may differ) Internet http://www.siemens.com/automation/support-request America Telephone +1 42...
Page 8 - Table of contents
Table of contents Preface ...................................................................................................................................................... 5 1 General safety guidelines ................................................................................................
Page 12 - General safety guidelines; Residual risks of power drive systems
General safety guidelines 1 Please observe all the relevant safety instructions to avoid personal and/or material damage. In particular, you must observe the safety instructions and notes regarding the powerful permanent magnets installed in the rotor of the built-in torque motor. The rotor is secur...
Page 13 - operation and / or improper disposal of components.; Observing and complying with safety guidelines
General safety guidelines 1.1 Observing and complying with safety guidelines 4. Operational electrical, magnetic, and electromagnetic fields that can pose a risk to people with a pacemaker and/or implants or metallic objects if they are too close. 5. Release of environmentally hazardous materials an...
Page 14 - Handling direct drives and components
General safety guidelines 1.2 Handling direct drives and components 1.2 Handling direct drives and components DANGER There is danger of death, serious bodily injury and/or property damage when untrained personnel is allowed to handle direct drives and/or their components. Only personnel who are fami...
Page 15 - Use for the intended purpose
General safety guidelines 1.3 Use for the intended purpose 1.3 Use for the intended purpose DANGER There is a risk of death, serious personal injury and/or serious material damage when direct drives or their components are used for a purpose for which they were not intended. The motors are designed ...
Page 16 - Danger from strong magnetic fields; Occurrence of magnetic fields; fields also occur during operation.; Components with permanent magnets; CAUTION
General safety guidelines 1.4 Danger from strong magnetic fields 1.4 Danger from strong magnetic fields Occurrence of magnetic fields Strong magnetic fields occur in the components of the motor that contain permanent magnets. The magnetic field strength of the motors results exclusively from the mag...
Page 18 - First aid in the case of accidents involving permanent magnets; Administer FIRST AID. Call for further help if required.
General safety guidelines 1.4 Danger from strong magnetic fields DANGER Strong attractive forces on magnetizable materials lead to a great danger of crushing in the vicinity of components with permanent magnets (distance less than 100 mm). Do not underestimate the strength of the attractive forces! ...
Page 19 - Electrical shock hazard!; Protective measures against residual voltages; Attaching warning signs; language of the country in which the product is used.
General safety guidelines 1.5 Electrical shock hazard! 1.5 Electrical shock hazard! DANGER Electrical shock hazard! When an installed torque motor rotates, potentially dangerous voltages are induced at the cable ends of the motor. Insulate terminals and leads in open cable ends or take measures to p...
Page 20 - Pictograms supplied for 1FW6
General safety guidelines 1.7 Pictograms supplied for 1FW6 1FW6 Built-in torque motors Configuration Manual, 05/2009, 6SN1197-0AE00-0BP3 21 1.7 Pictograms supplied for 1FW6 To indicate dangers, the following durable adhesive stickers are supplied: Table 1- 1 Warning signs to BGV A8 / DIN 4844-2 and ...
Page 22 - Description of the motor; FW6 built-in torque motor; Properties; Overview
Description of the motor 2 1FW6 built-in torque motor 2.1 Properties 2.1.1 Overview 1FW6 torque motors are designed as built-in motors for use in low-speed direct drives with a high torque output. Built-in torque motors are liquid-cooled, permanent-magnet-excited, (high pole number) three-phase sync...
Page 23 - Benefits
Description of the motor 2.1 Properties and spacer film. For a complete drive unit, an additional bearing and rotary transducer are required. The product range includes 7 frame sizes (or external diameters), each with at least 4 different axis lengths. Each motor is available for at least two differ...
Page 24 - Applications; Technical features
Description of the motor 2.2 Technical features 2.1.3 Applications In conjunction with the SINAMICS S120 drive system (booksize or blocksize format), the built-in torque motors can be used as a direct drive for the following machine applications: ● Rotary indexing machines, rotary tables, swivel axe...
Page 27 - UL approval; can be taken from the Conditons of Acceptability.; Direction of rotation
Description of the motor 2.2 Technical features Table 2- 6 Mechanical ambient conditions Long-term storage: Class 1M2 Transport: Class 2M2 Fixed location: Class 3M3 UL approval The torque motors described in this documentation have been approved by Underwriters Laboratories Inc. (USA) (UL). Validity...
Page 28 - Selection and ordering data
Description of the motor 2.3 Selection and ordering data 2.3 Selection and ordering data Table 2- 7 Built-in torque motors: overview (part 1 of 2) Order desig. / Size Rated torque 1) M N in Nm Max. torque M MAX in Nm Rated current 1) I N in A Max. current I MAX in A Max. speed at rated torque 2) n M...
Page 33 - Order designation; Structure of the order designations
Description of the motor 2.4 Order designation Order desig. / size Rated power loss 1) P V,N in kW External diameter of stators in mm Internal diameter of rotors in mm Length of stator in mm Motor mass 3) in kg Moment of inertia of rotor J L in 10 -2 kgm 2 1FW6230-xxB10-8Fxx 5.95 576 416 160 81.8 11...
Page 34 - Standard 1FW6 built-in torque motor
Description of the motor 2.4 Order designation 2.4.2 Standard 1FW6 built-in torque motor &XUUHQWUHTXLUHPHQWVLQIRUPDWLRQRQ0RWRU0RGXOH) 6,1$0,&660RWRU0RGXOH$$. 6,1$0,&660RWRU0RGXOH$$- 6,1$0,&660RWRU0RGXOH$$- 6,1$0,&660RWRU0RGXOH$$& 6,1$0,&660RWRU0RGXOH$$) 6,1$0,&660RWRU...
Page 35 - Stator as individual component
Description of the motor 2.4 Order designation 2.4.3 Stator as individual component &XUUHQWUHTXLUHPHQWVLQIRUPDWLRQRQ0RWRU0RGXOH) 6,1$0,&660RWRU0RGXOH$$. 6,1$0,&660RWRU0RGXOH$$- 6,1$0,&660RWRU0RGXOH$$- 6,1$0,&660RWRU0RGXOH$$& 6,1$0,&660RWRU0RGXOH$$) 6,1$0,&660RWRU0RGXO...
Page 36 - Rotor as individual component
Description of the motor 2.4 Order designation 2.4.4 Rotor as individual component ): [[ 5 $ [[ $$ )UDPHVL]HH[WHUQDOGLDPHWHURIVWDWRU PP PP PP PP PP PP PP 'LUHFWO\GULYHQKROORZVKDIWPRWRUDVWKUHHSKDVHV\QFKURQRXVPRWRU ,QGLYLGXDOFRPSRQHQW 5RWRU /HQJWKRIDFWLYHSDUWLQ>FP@ PP PP PP PP PP PP 2.4.5 Round sea...
Page 37 - Cooling connection adapter; Plug connector
Description of the motor 2.4 Order designation 2.4.6 Cooling connection adapter ): [[ % $ $$ 'LUHFWO\GULYHQKROORZVKDIWPRWRUDVWKUHHSKDVHV\QFKURQRXVPRWRU % &RROLQJFRQQHFWLRQDGDSWHUIRUEXLOWLQPRWRUZLWKLQWHJUDWHGFRROLQJ QRWDYDLODEOHIRUVL]HVDQGDVWKHVHDUHWKHPRWRUVZLWKFRROLQJMDFNHWFRPELFRQQHFWLRQIRUPDLQ...
Page 38 - Ordering examples
Description of the motor 2.4 Order designation Note If, for design reasons, only individual components can be installed (stator and rotor separately), these can be ordered and shipped separately. DANGER Due to the risk of compression caused by the attractive forces of the rotor, an installation devi...
Page 39 - Motor rating plate; each other at a later stage.; Data on the motor rating plate
Description of the motor 2.5 Motor rating plate 1FW6 Built-in torque motors 40 Configuration Manual, 05/2009, 6SN1197-0AE00-0BP3 2.5 Motor rating plate Note A motor rating plate is attached to each stator. A second rating plate, which the customer can attach to the machine in which the motor is inst...
Page 40 - Motor components of the built-in motor and options; Overview of the motor construction; Motor components; this comprises an iron core and a 3-phase winding.; Motors with a cooling jacket
Motor components of the built-in motor and options 3 3.1 Overview of the motor construction Motor components The built-in torque motor contains the following components: ● Stator: this comprises an iron core and a 3-phase winding. The winding is encapsulated to ensure that the heat loss can be dissi...
Page 41 - UDQVSRUWDWLRQORFNV; signal connection with connector or open core ends; Motors with integrated cooling
Motor components of the built-in motor and options 3.1 Overview of the motor construction 6WDWRUZLWKFRROLQJMDFNHW 5RWRUZLWKSHUPDQHQWPDJQHWV 7UDQVSRUWDWLRQORFNV (OHFWULFDOFRQQHFWLRQV Figure 3-1 1FW6 motor components with a cooling jacket Scope of delivery of the built-in torque motor with a cooling j...
Page 42 - Transportation locks with spacers and screws; Cooling method
Motor components of the built-in motor and options 3.1 Overview of the motor construction 5RWRUZLWKSHUPDQHQWPDJQHWV 6WDWRUZLWKLQWHJUDWHGFRROLQJ &RROHUFRQQHFWLRQ 7UDQVSRUWDWLRQORFNV (OHFWULFDOFRQQHFWLRQV Figure 3-2 1FW6 motor components with integrated cooling Scope of delivery of the built-in to...
Page 43 - Thermal motor protection; Description of the temperature sensors; Temperature sensor; monitor the temperature during commissioning and operation.; Temp–S; resistance occurs at the rated response temperature θ; high stator temperatures.
Motor components of the built-in motor and options 3.2 Thermal motor protection Table 3- 1 Cooling method Size Cooling jacket Integrated cooling 1FW609 X 1FW613 X 1FW615 X 1FW616 X 1FW619 X 1FW623 X 1FW629 X 3.2 Thermal motor protection 3.2.1 Description of the temperature sensors Temperature sensor...
Page 45 - determine the instantaneous temperature.; Temp–F; WARNING
Motor components of the built-in motor and options 3.2 Thermal motor protection Note The PTC thermistors do not have a linear characteristic and are, therefore, not suitable to determine the instantaneous temperature. Temp–F The temperature sensor circuit comprises a temperature sensor (KTY 84). For...
Page 47 - Evaluation of the temperature sensors for motor protection; Cooling
Motor components of the built-in motor and options 3.3 Cooling 3.2.2 Evaluation of the temperature sensors for motor protection Temp–S Temp–S is used to reliably protect the motor against overheating. If Temp–S responds, then the drive must be quickly shut down in order to prevent the drive converte...
Page 48 - NOTICE; Effects when water cooling is not used; of the motor can be fully utilized here.
Motor components of the built-in motor and options 3.3 Cooling NOTICE If the heat from the rotor cannot be sufficiently dissipated via the flange, this can cause the rotor to heat up excessively in the upper speed range in S1 mode, which could demagnetize the magnets. Note Depending on the load and ...
Page 49 - Cooling circuits; Cooling circuit requirements
Motor components of the built-in motor and options 3.3 Cooling 3.3.1 Cooling circuits Cooling circuit requirements We recommend that the cooling circuits be designed as closed systems, to prevent the growth of algae. The maximum permissible pressure is 10 bar. Note We do not recommend that the cooli...
Page 50 - ,QIOXHQFHRIFRRODQWLQOHWWHPSHUDWXUH; Dimensioning the heat-exchanger unit
Motor components of the built-in motor and options 3.3 Cooling Coolant intake temperature The intake temperatures must be selected in such a way that no condensation forms on the surface of the motor. Condensation can lead to corrosion in the machine. T kühl ≥ T Umgeb - 2 K The motors are designed i...
Page 51 - Coolant; Provision of the cooling medium
Motor components of the built-in motor and options 3.3 Cooling During continuous operation, the motor can only be loaded to the extent that the effective continuous torque M eff does not exceed the rated torque M N . As a result, therefore, the effective power loss cannot exceed the rated power loss...
Page 54 - Coupled motors; Parallel operation of several motors; Parallel operation of several motors on one axes; section; Requirements; Only identical motors are suitable for parallel operation.
Coupled motors 4 4.1 Parallel operation of several motors Parallel operation of several motors on one axes Provided that certain prerequisites are fulfilled, built-in torque motors can be operated in parallel on a single axis and supplied by a joint power unit. Drawings: see the end of this section ...
Page 55 - Motor arrangements; or; Janus arrangement; Power connection for parallel operation
Coupled motors 4.1 Parallel operation of several motors CAUTION If the angular position is set incorrectly, this can result in a thermal overload of one of the two parallel motors during continuous operation at the rated load. For this reason, it may be necessary to reduce the torque depending on th...
Page 60 - Configuring the motor; The peak and continuous torque required for the application; Procedure
Configuring the motor 5 5.1 Procedure Requirements Your choice of torque motor depends on the following factors: ● The peak and continuous torque required for the application ● The required speed and angular acceleration ● The installation space available ● The required/possible drive arrangement (s...
Page 62 - General mechanical conditions; Specification of the duty cycle
Configuring the motor 5.1 Procedure 5.1.1 General mechanical conditions Moment of inertia The kinetic energy generated by a rotating body is directly proportional to its moment of inertia J in kgm 2 . The moment of inertia takes into account the rotating mass and its spatial distribution across the ...
Page 63 - time diagrams α (t) in accordance with the following correlations:; Example; The required motor torque M
Configuring the motor 5.1 Procedure Angle-time diagrams and speed-time diagrams can be converted to angular acceleration- time diagrams α (t) in accordance with the following correlations: Example Figure 5-1 Example of a duty cycle with a speed-time diagram n(t), the resulting angular acceleration-t...
Page 64 - (see diagram below) from which the required peak torque M; can be read directly.; , the required continuous torque M; of the motor is also
Configuring the motor 5.1 Procedure Determining the required motor torque The frictional torque characteristic can be determined on the basis of the speed characteristic. The totals formula can then be used to create the motor torque-time diagram (see diagram below) from which the required peak torq...
Page 65 - Selecting the motors
Configuring the motor 5.1 Procedure 0 HII If the individual torques are stable in each section, the integral can be simplified to create a totals formula (see also the following diagram). 0 HII 0 HII Figure 5-3 Motor torque-time diagram 5.1.4 Selecting the motors You can choose a suitable torque mot...
Page 66 - Uneven current load; Checking the torques and speeds
Configuring the motor 5.1 Procedure 5.1.5 Uneven current load If the load is uneven over a long period of time, the motor must only be operated at no more than 70% of the rated torque (see also M 0 * in "Technical data"). For exact configurations, contact your local Siemens office. NOTICE No...
Page 67 - , and the associated speeds n; Torque-speed requirements; Fulfilling the torque-speed requirements
Configuring the motor 5.1 Procedure Determining the motor torque-speed diagram If a motor torque-speed diagram is not available, the relevant values can be determined with sufficient accuracy using the specifications for the maximum torque M MAX , the rated torque M N , and the associated speeds n M...
Page 68 - controller as well as the motor type.; More than one torque motor on one axes; Electrical parallel connection; Checking the moments of inertia; regarding the duty cycle.
Configuring the motor 5.1 Procedure no longer purely sinusoidal. As a result, the torque generated by the motor is no longer uniform but instead has a ripple. The extent to which the maximum speed can be overridden depends on the permissible following error and positioning error in the controller as...
Page 69 - Selecting the drive system components for the power connection; Infeed power
Configuring the motor 5.1 Procedure Recalculating the duty cycle If the moment of inertia initially assumed deviates significantly from the actual moment of inertia, the duty cycle may have to be recalculated. 5.1.10 Selecting the drive system components for the power connection The drive system com...
Page 70 - resistance R; This equation can be used for every point in time in the duty cycle.; Selecting an infeed unit; the motor accelerates to the maximum speed (see operating point M
Configuring the motor 5.2 Example(s) The speed n in rpm can be converted to the angular velocity as follows: Example: converting the speed n = 80 rpm to the angular velocity ω The value for the rated temperature of the motor winding must be applied for the phase resistance R STR (T) (see also "E...
Page 71 - The following must be determined:
Configuring the motor 5.2 Example(s) General conditions for positioning within a defined period ● Moment of inertia in kgm 2 : J = 5.1 kg m 2 ; moving cylindrical mass m = 30 kg with substitute radius r = 0.583 m; rotary axes of moving mass and motor are identical; calculated from: Figure 5-7 Moment...
Page 72 - defined end angle φ; and the corresponding time t
Configuring the motor 5.2 Example(s) Figure 5-8 Ideal traversing profile with angular acceleration α (t), angular velocity ω (t), and angle φ (t) Table 5- 1 Functions of the individual sections in the traversing profile Section I Section II α I (t) = α α II (t) = - α ω I (t) = α t ω II (t) = - α t +...
Page 73 - LQRULQ; LQ
Configuring the motor 5.2 Example(s) transitional phases between acceleration/deceleration and the resulting angle changes are not taken into account. Since the areas below the curves for ω (t) are the same in both sections, the following applies: LQRULQ LQ The angular velocity ω MAX achieved at t 1...
Page 75 - Short-time duty S2 and intermittent duty S3; yOQ
Configuring the motor 5.3 Short-time duty S2 and intermittent duty S3 5.3 Short-time duty S2 and intermittent duty S3 Short-time duty S2 In the case of short-time duty S2, the load time is so short that the final thermal state is not reached. The subsequent zero-current break is so long that the mot...
Page 78 - Motor assembly; Important information about motor assembly
Motor assembly 6 6.1 Motor assembly Important information about motor assembly Before assembling the motor, the assembly instructions provided in this documentation must be read carefully. DANGER Installing torque motors involves carrying out work in the vicinity of unpacked rotors. The resulting da...
Page 81 - PP; Axial forces between the stator and rotor; Requirements of the installation device
Motor assembly 6.1 Motor assembly Example With torque motor 1FW6090-0Px010-xxxx (active component length: 100 mm), the eccentricity is 0.2 mm, for example. The active radial force as a result of this centering error is, therefore: PP 1 PP 1 Axial forces between the stator and rotor Table 6- 2 Axial ...
Page 83 - values specified in the table above.; Procedure for installing the motor; Sequence for installing the motor
Motor assembly 6.1 Motor assembly Type series Screw (strength class) Tightening torque M A in Nm 1FW6160-xxB05-xxxx to 1FW6160-xxB15-xxxx M8 (8.8) 21.6 1FW6160-xxB20-xxxx M8 (10.9) 31.8 1FW6190-xxB05-xxxx to 1FW6190-xxB15-xxxx M8 (8.8) 21.6 1FW6190-xxB20-xxxx M8 (10.9) 31.8 1FW6230-xxB05-xxxx to 1FW...
Page 85 - packaging and storage of the motor.; Example: centering and installing motors with a cooling jacket; the sleeve bearing and shaft in the stator.
Motor assembly 6.1 Motor assembly 8. Remove the spacer film. When the stator and rotor are correctly centered, the spacer film can be easily removed by hand. Keep spacer film safe for subsequent transport, packaging and storage of the motor. 9. Make sure that the rotor can move without hindrance. Ma...
Page 87 - Cooler connection; Installing the cooling connection adapter
Motor assembly 6.1 Motor assembly 6.1.2 Cooler connection For more information about connecting the cooler, see "Interfaces". Installing the cooling connection adapter The components required for connecting the cooler for motors with integrated cooling can usually be installed with standard ...
Page 89 - Information on routing cables; bending stresses that occur.
Motor assembly 6.1 Motor assembly $OOGLPHQVLRQVLQPP &RROLQJFRQQHFWLRQDGDSWHULVQRWLQFOXGHGLQWKHVFRSHRIVXSSO\ &RROHUFRQQHFWLRQRSWLRQDO 6WDWRU &RROHUFRQQHFWLRQRSWLRQDO &RROLQJFRQQHFWLRQSODWHLVSHUPDQHQWO\DWWDFKHGWRWKHVWDWRU &\OLQGHUKHDGVFUHZ,620[$7LJKWHQLQJWRUTXHWR1P Figure 6-3 Insta...
Page 90 - Checking the work carried out; Checking the installation work
Motor assembly 6.1 Motor assembly The following should be observed when routing and connecting up motor supply cables: ● The minimum bending radii (see "Electrical connections") for moving power cables must be observed (see catalog NC 61). ● The cables may not chafe anywhere. ● The cables mu...
Page 91 - Installation examples; rotor or on the opposite side.
Motor assembly 6.1 Motor assembly 6.1.5 Installation examples Note The examples provided below are not necessarily complete nor are they suitable for all applications. Note that the rotor and stator are secured on one side on the machine construction. Depending on the machine construction, the stato...
Page 99 - Protecting the motor components; Degree of protection
Motor assembly 6.2 Protecting the motor components 1FW6 Built-in torque motors 100 Configuration Manual, 05/2009, 6SN1197-0AE00-0BP3 6.2 Protecting the motor components Degree of protection The machine construction surrounding the motor must fulfill at least degree of protection IP54 (to EN 60529). ...
Page 100 - System integration; System requirements; Components
System integration 7 7.1 System requirements Components The drive system that feeds a motor comprises an infeed module, a power module and a control module. For the SINAMICS S120 drive system, these modules are called "Line Modules", "Motor Modules" and "Control Units". The L...
Page 103 - protect the motor insulation from excessive stress.; and a speed 1; Drive system
System integration 7.1 System requirements Permissible voltages The following table shows the permissible line voltages of TN line supply systems for the motors. Table 7- 1 Permissible line voltages of TN line supply systems, resulting DC link voltages and converter output voltages Permissible line ...
Page 105 - Encoders; Encoder system; Requirements regarding the encoder
System integration 7.2 Encoders ● Quantification of the angular signal and speed signal (the number of encoder lines and their multiplication in the encoder evaluation of the converter for each axes rotation and the measuring accuracy of the encoder are crucial here). ● Sampling time of the current,...
Page 106 - when configuring, installing, and adjusting the encoder
System integration 7.2 Encoders Note To ensure a high control loop dynamic response (high k V factor), rapid, overshoot-free positioning, and smooth running, measuring systems that emit a minimum of approx. 10,000 pulses/revolution are recommended. Note To protect against contamination, the housing ...
Page 107 - *RRGHQFRGHUDUUDQJHPHQW
System integration 7.2 Encoders ವವವ ವವವ *RRGHQFRGHUDUUDQJHPHQW /DUJHGLVWDQFHEHWZHHQWKHPRWRUDQGPRWRUHQFRGHU/DFNRIULJLGLW\GXHWRDQH[FHVVLYHO\WKLQSODWHIRUVHFXULQJWKHPRWRUHQFRGHU)RUFHLQWURGXFWLRQEHWZHHQWKHPRWRUDQGPRWRUHQFRGHU +\GUDXOLFGLVWULEXWRU 5RWDU\WDEOH %HDULQJ 6WDWRU 5RWRU (QFRGHU 6PDOOGLVWDQFHEHWZ...
Page 108 - Bearings; Selecting the bearing; Geometric requirements (internal and external diameter); Braking concepts
System integration 7.3 Bearings 7.3 Bearings Selecting the bearing 1FW6 torque motors are built-in motors for direct rotary or swivel axes. To set up a complete drive unit, a bearing between the stator and rotor is required in addition to the phase-angle encoder system. Your choice of bearing is gov...
Page 110 - Mechanical braking via braking elements:; Deploying a holding brake
System integration 7.4 Braking concepts 1FW6 Built-in torque motors Configuration Manual, 05/2009, 6SN1197-0AE00-0BP3 111 3. Mechanical braking via braking elements: The braking capacity must be dimensioned as highly as possible so that the rotating masses can be reliably braked at maximum kinetic e...
Page 112 - Interfaces; Electrical connection components
Interfaces 8 8.1 Overview Electrical connection components Table 8- 1 Overview of available motor types with respect to the position of the electrical connection MLFB Outgoing feeder Strain relief 1FW6090-0PBxx-xxxx Axial Sleeve 1FW6090-0QBxx-xxxx Radial (outward) Sleeve 1FW6090-0NBxx-xxxx Tangentia...
Page 140 - (OHFWULFDOFRQQHFWRUSLQDVVLJQPHQWV
Interfaces 8.1 Overview 3RZHUFRQQHFWRUVL]H3ROHSDWWHUQYLHZRIPDWLQJVLGH LVQRWHYDOXDWHGE\WKH60([ 6LJQDOFRQQHFWRU03ROHSDWWHUQYLHZRIPDWLQJVLGH (OHFWULFDOFRQQHFWRUSLQDVVLJQPHQWV 3RZHUFRQQHFWRUVL]H3ROHSDWWHUQYLHZRIPDWLQJVLGH (OHFWULFDOFRQQHFWRUSLQDVVLJQPHQWV Figure 8-29 PIN assignments for the connectors 1...
Page 141 - Electrical connections
Interfaces 8.2 Electrical connections 8.2 Electrical connections DANGER Risk of death, serious personal injury (electrical shock), and/or material damage if direct drives are connected incorrectly. Motors must be connected in accordance with the circuit diagram provided in this documentation and req...
Page 142 - Power connection; Connection assignment; Signal connection
Interfaces 8.2 Electrical connections The cables for the power connection are brought out at the front of the stator (B side). The open cable ends must be connected in a terminal box, which must be provided by the machine manufacturer. Sufficient installation space must be provided in the axes const...
Page 144 - Shielding, grounding, and equipotential bonding; Rules
Interfaces 8.2 Electrical connections 8.2.3 Shielding, grounding, and equipotential bonding Rules Correct installation and connection of the cable shields and protective conductors is very important, not only for personal safety but also for the effect on emissivity and noise immunity. Therefore, th...
Page 145 - Requirements for the motor supply cables; Motor supply cables; Specification of the motor supply cables; Cooler connection for motors with a cooling jacket
Interfaces 8.3 Cooler connection NOTICE With 1FW6 built-in torque motors featuring single-core power cables without a PE cable, a connection point is provided for the PE. A separate PE cable must be connected to this to ensure a direct connection to the power unit. 8.2.4 Requirements for the motor s...
Page 147 - Cooler connection for motors with integrated cooling; be supplied and switched separately.
Interfaces 8.3 Cooler connection &XVWRPHUKRXVLQJ 2XWJRLQJIHHGHUH[LWSRLQW 2ULQJV 5RWRU 6WDWRU /RFDWLQJKROHURWRU $OOGLPHQVLRQVLQPP ,QOHW :DWHUFRROLQJ 2XWOHW Figure 8-32 Cooler connection for 1FW615 (example) Cooler connection for motors with integrated cooling For built-in torque motors with integ...
Page 157 - Hoses for the cooling system; accessories for cooling systems, see the appendix.
Interfaces 8.3 Cooler connection 1FW6 Built-in torque motors 158 Configuration Manual, 05/2009, 6SN1197-0AE00-0BP3 Hoses for the cooling system The hoses for the cooling system must be highly resistant to the coolant, flexible, and abrasion proof. The hoses for the cooling system should not be chose...
Page 158 - Commissioning; Safety guidelines for commissioning
Commissioning 9 9.1 Safety guidelines for commissioning DANGER Risk of death, serious personal injury, and/or material damage if a machine that does not fulfill the recognized safety requirements is commissioned. Plants and machines with converter-fed low-voltage three-phase motors must fulfill the ...
Page 159 - Commutation setting
Commissioning 9.1 Safety guidelines for commissioning WARNING The surface temperature of the motors may be more than 100 °C (212 °F). Risk of burns Make sure that the cooling system (if available) is working properly. Do not touch the motor during/directly after use. Display the "Hot Surface Do ...
Page 161 - Checks for commissioning in a current-free state
Commissioning 9.2 Procedure Commissioning the cooling circuits Before the cooling circuits are charged, they must be rinsed with the cooling medium. NOTICE The maximum permissible pressure in the cooling circuit (see "Technical features") must not be exceeded. 9.2 Procedure Checks for commis...
Page 164 - Operation; Safety guidelines for operation; Dealing with faults
1FW6 Built-in torque motors Configuration Manual, 05/2009, 6SN1197-0AE00-0BP3 165 Operation 10 10.1 Safety guidelines for operation DANGER Due to the high speeds and acceleration as well as the friction and self-locking, machine parts that are driven with torque motors pose a considerable risk of in...
Page 166 - Maintenance and repairs; Safety information for maintenance and repairs; , the cooler must remain
Maintenance and repairs 11 11.1 Safety information for maintenance and repairs DANGER Risk of death, serious personal injury and/or material damage if maintenance and repair work is carried out by inexperienced personnel. Make sure that maintenance personnel possess the knowledge, ability, and exper...
Page 168 - Safety guidelines for high-voltage test; Maintenance; Performing maintenance work on the motor
Maintenance and repairs 11.2 Safety guidelines for high-voltage test 11.2 Safety guidelines for high-voltage test Guidelines for inspecting the insulation resistance (high-voltage test) WARNING An insulation resistance inspection under high-voltage conditions can damage the motor insulation! If insu...
Page 169 - Intervals between maintenance; Test and replacement intervals of the cooling medium
Maintenance and repairs 11.4 Test and replacement intervals of the cooling medium 1FW6 Built-in torque motors 170 Configuration Manual, 05/2009, 6SN1197-0AE00-0BP3 ● Regularly check that the rotary axes can move without hindrance. ● Keep the air gap free of chippings and particles. ● Regularly check...
Page 170 - Storage and transport; Packaging, storage, and transport guidelines
Storage and transport 12 12.1 Packaging, storage, and transport guidelines When packing/unpacking and transporting torque motors or rotors, take measures to minimize risks posed by strong magnetic fields from the rotors (see also "Danger from strong magnetic fields"). DANGER Risk of death, i...
Page 171 - Safety note regarding lifting devices
Storage and transport 12.2 Safety note regarding lifting devices 1FW6 Built-in torque motors 172 Configuration Manual, 05/2009, 6SN1197-0AE00-0BP3 DANGER Danger of tilting Motors, stators, and rotors must not be stacked too high – risk of death, personal injury and/or material damage. Motors, stator...
Page 172 - Environmental compatibility; Environmental compatibility during production; Guidelines for disposal; Main constituents of a proper disposal procedure
Environmental compatibility 13 13.1 Environmental compatibility during production ● There is no need to transport hazardous materials. ● The packaging material is made primarily from cardboard. ● Energy consumption during production was optimized. ● Production has low emission levels. 13.2 Disposal ...
Page 173 - Disposing of 1FW6 rotors; Disposing of and demagnetizing 1FW6 rotors; Demagnetizing the rotors; Disposal of packaging
Environmental compatibility 13.2 Disposal 1FW6 Built-in torque motors 174 Configuration Manual, 05/2009, 6SN1197-0AE00-0BP3 13.2.2 Disposing of 1FW6 rotors Disposing of and demagnetizing 1FW6 rotors The magnetized rotors must be subject to a special thermal disposal procedure so that they do not pos...
Page 174 - Technical data and characteristics; Explanations of the formula abbreviations; Content of the data sheet
Technical data and characteristics 14 The technical data and characteristics for the 1FW6 Built-in torque motors are specified in this Chapter. This data collection provides the motor data required for configuration and contains a number of additional data for more detailed calculations for detailed...
Page 176 - Physical constants
Technical data and characteristics 14.1 Explanations of the formula abbreviations n MAX,MMAX Maximum speed up to which the motor can deliver the maximum torque M MAX . n MAX,0 No-load speed; max. speed without load. M 0 Torque for speed n = 1 [rpm] at which the load and power loss are still evenly d...
Page 179 - Data, precision motor cooler
Technical data and characteristics 14.1 Explanations of the formula abbreviations 3UHVVXUHGURSDWUHFRPPHQGHGPLQLPXPYROXPHIORZUDWHDFFRUGLQJWRGDWDVKHHW ˂SLQEDU 9LQOPLQ Figure 14-3 Sample characteristic: "Pressure losses in the main cooler over volume flow rate" Data, precision motor cooler Q P,...
Page 180 - means that the torque M
Technical data and characteristics 14.1 Explanations of the formula abbreviations Speed-torque diagram The circle on the torque axes shown in the following diagram represents M *0 . The motors described are multi-pin and have a sufficiently large thermal time constant. This means that the torque M 0...
Page 181 - Data sheets and diagrams
Technical data and characteristics 14.2 Data sheets and diagrams 14.2 Data sheets and diagrams 14.2.1 1FW6090-xxxxx-xxxx Data sheet 1FW6090-xxB05-xxxx Table 14- 1 1FW6090-xxB05-0Fxx, 1FW6090-xxB05-0Kxx Technical data 1FW6090 Symbol Unit -xxB05-0Fxx -xxB05-0Kxx Boundary conditions DC link voltages U ...
Page 278 - Installation drawings/Dimension drawings; Installation situation for motors with a cooling jacket; Design information for installation hole and O ring; and polished; sufficient sealing or the permissible gap is too large.
Installation drawings/Dimension drawings 15 15.1 Installation situation for motors with a cooling jacket Design information for installation hole and O ring ● Provide insertion inclines: Minimum length Z at 15°: 3 mm, at 20°: 2 mm, edges rounded and polished Debur and round inside holes (cooling wat...
Page 279 - Explanation of installation drawings; Installation dimensions
Installation drawings/Dimension drawings 15.2 Explanation of installation drawings 15.2 Explanation of installation drawings Installation dimensions The following design-related dimensions must be taken into account. Figure 15-2 Geometry data for 1FW6 Built-in torque motors Explanation of the abbrev...
Page 290 - Appendix; Recommended manufacturers; Information regarding third-party products; units
Appendix A A.1 Recommended manufacturers Information regarding third-party products NOTICE This document contains recommendations relating to third-party products. This involves third-party products whose fundamental suitability is familiar to us. It goes without saying that equivalent products from...
Page 291 - Supply sources for cooling systems
Appendix A.1 Recommended manufacturers Serto GmbH Kasseler Strasse 64 D-34277 FULDABRÜCK, Germany Phone: +49 (0) 5 61 - 5 80 04 - 0 Fax: +49 (0) 5 61 - 5 80 04 - 44 E-mail: [email protected] www.serto.com SMC Pneumatik GmbH Boschring 13 - 15 63329 EGELSBACH Phone: +49 (0) 61 03 - 4 02 - 0 Fax: +49 (...
Page 292 - Supply sources for anti-corrosion agents
Appendix A.1 Recommended manufacturers Hydac International GmbH Industriegebiet 66280 Sulzbach/Saar, Germany Phone: +49 (0) 68 97 - 5 09 - 01 E-mail: [email protected] www.hydac.com Rittal GmbH & Co. KG Auf dem Stützelberg 35745 Herborn, Germany Phone: +49 (0) 27 72 - 5 05 - 0 Fax: +49 (0) 27 72...
Page 293 - Supply sources for braking elements
Appendix A.1 Recommended manufacturers A.1.4 Supply sources for braking elements HEMA Maschinen und Apparateschutz GmbH Seligenstädter Straße 82 63500 SELIGENSTADT Phone: +49 (0) 61 82 - 7 73 - 0 Fax: +49 (0) 61 82 - 7 73 - 35 E-mail: [email protected] www.hema-schutz.de Chr. Mayr GmbH + Co. KG Eich...
Page 294 - RVWDOFRGH
Appendix A.2 Fax form for suggestions/corrections (copy template) A.2 Fax form for suggestions/corrections (copy template) Should you come across any printing errors when reading this publication, please notify us on this sheet. We would also be grateful for any suggestions and recommendations for i...
Page 295 - List of abbreviations
Appendix A.3 List of abbreviations A.3 List of abbreviations abs. WMS Absolute angular position measuring system, absolute encoder BGR Health and safety at work regulations (in Germany) BGV Binding national health and safety at work regulations (in Germany) CE Communauté Européenne (European Communi...
Page 298 - Index
1FW6 Built-in torque motors Configuration Manual, 05/2009, 6SN1197-0AE00-0BP3 299 Index A Abbreviations, 297 Accidents First aid, 19 Anti-corrosion protection, 53 Approvals, 28 Axial forces, 82 B Bearings, 109 Braking, 109 Braking concepts, 110 C Characteristics for 1FW6090-xxx05-xxxx, 183 Character...