Siemens RDU340 - User Manual

Siemens RDU340

Siemens RDU340 – User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
Page: / 10

Table of Contents:

  • Page 2 – Use
  • Page 3 – Applications; DIP switch number; Application; eating or cooling; Type summary; Control output
  • Page 5 – Mechanical design; The controller consists of 2 parts:; Operation and settings
  • Page 6 – Mounting and installation
  • Page 7 – Technical data
  • Page 9 – Connection terminals; Connection diagrams
  • Page 10 – Dimensions; Dimensions in mm; 008 Siemens Switzerland Ltd.
Loading the manual
Page 1

N3078en
11 July 2008

Building Technologies

3

078

Semi Flush-mount
Room Temperature
Controllers with LCD

RDU340

for VAV heating and cooling systems

•

Modulating PI control

•

Control depending on the room or the return air temperature

•

Output for a DC 0…10 V actuator and AC 230V electrical heater (ON-OFF)

•

Automatic or manual heating/cooling changeover

•

Operating modes: Comfort, Energy Saving and Protection

•

Two multifunctional inputs for keycard contact, external sensor, etc.

•

Adjustable commissioning and control parameters

•

Minimum and maximum setpoint limitation

•

Adjustable minimum and maximum limitation for air flow signal DC 0..10V

•

Output signal inversion as an option

•

Mounting on recessed rectangular conduit box, 60.3 mm fixing centers

•

AC 24 V operating voltage

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Was this manual helpful?

About this manual

Brand
Siemens
Model
RDU340
Document type
User Manual
Language(s)
English
Pages
10
File size
156.3 KB
Format
PDF

Summary

Page 2 - Use

2/10 Siemens RDU340 – Room Temperature Controllers N3078en Building Technologies 11 July 2008 Use Control of the room temperature in individual rooms of ventilation or air conditioning plants that are: • Heated or cooled by single duct. • Heated or cooled by single duct with electrical heater. The R...

Page 3 - Applications; DIP switch number; Application; eating or cooling; Type summary; Control output

3/10 Siemens RDU340 – Room Temperature Controllers N3078en Building Technologies 11 July 2008 Applications Prior to snapping the front panel to the base, use the DIP switches on the inner side of the front panel to commission the controller applications and the behavior of the output signal. DIP swi...

Page 5 - Mechanical design; The controller consists of 2 parts:; Operation and settings

5/10 Siemens RDU340 – Room Temperature Controllers N3078en Building Technologies 11 July 2008 Mechanical design The controller consists of 2 parts: • Front panel accommodating the electronics, operating elements and built-in room temperature sensor. • Mounting base with the power electronics. The re...

Ask a question

Up to 3 photos. Max 5 MB each. Formats: JPG, JPEG, PNG, WebP.