Siemens RDG160KN - User Manual

Siemens RDG160KN

Siemens RDG160KN – User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
Page: / 21

Table of Contents:

  • Page 2 – Siemens
  • Page 3 – Functions
  • Page 5 – Applications, DIP setting, Control outputs; heated ceiling; Control outputs
  • Page 6 – Key
  • Page 8 – Accessories
  • Page 9 – Mechanical design; The room thermostat consists of 2 parts:; Operation and settings
  • Page 10 – Display
  • Page 12 – ETS
  • Page 13 – application. The factory setting is as follows:; Application; = Heating and cooling; Disposal; Dispose of the device via the channels provided for this purpose.; Control sequence; Programming mode
  • Page 14 – Caution
  • Page 15 – Fans must NOT be connected in parallel!
  • Page 17 – Reference documentation
  • Page 18 – Connection terminals
  • Page 20 – radiator; YHC
  • Page 21 – Dimensions; Subject to change
Loading the manual
Page 1

s

3

191

Room thermostats with
KNX communications

RDG100KN
RDG160KN

– For fan coil unit applications

– For universal applications

– For use with compressor in DX type equipment

•

KNX bus communication (S-mode and LTE mode)

•

Backlit display

•

2P / PI / P control

•

Outputs for On/Off, PWM, 3-position or DC 0...10 V control

•

Outputs for 3-speed, 1-speed, or DC (DC 0...10 V) fan

•

3 multifunctional inputs for keycard contact, external sensor, etc.

•

Operating modes: Comfort, Economy and Protection

•

Automatic or manual fan speed control

•

Automatic or manual heating / cooling changeover

•

Minimum and maximum limitation of room temperature setpoint

•

Control depending on the room or the return air temperature

•

Selectable relay output functions (RDG160KN)

•

Adjustable commissioning and control parameters

•

Commissioning with Synco ACS, ETS or via local HMI

•

Integration into Synco

•

Integration into Desigo via group addressing (ETS) or via individual
addressing

•

Integration into third-party system via group addressing (ETS)

•

Operating voltage:
RDG100KN: AC 230 V
RDG160KN: AC 24 V

Edition 3.2

CE1N3191en

2014-05-23

Building Technologies

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Was this manual helpful?

About this manual

Brand
Siemens
Model
RDG160KN
Document type
User Manual
Language(s)
English
Pages
21
File size
520 KB
Format
PDF

Summary

Page 2 - Siemens

Use The RDG1...KN room thermostats are designed for use with the following types of system: Fan coil units via On/Off or modulating / DC control outputs: • 2-pipe system • 2-pipe system with electric heater • 2-pipe system and radiator / floor heating • 4-pipe system • 4-pipe system with electric he...

Page 3 - Functions

Functions • Room temperature control via built-in temperature sensor or external room temperature / return air temperature sensor • Changeover between heating and cooling mode (automatic via local sensor or bus, or manual) • Selection of applications via DIP switches or commissioning tool (ACS, ETS)...

Page 5 - Applications, DIP setting, Control outputs; heated ceiling; Control outputs

Applications for Universal systems Applications, DIP setting, Control outputs • Chilled / heated ceiling 1 2 3 4 5 ON OFF • Chilled / heated ceiling and electric heater 1 2 3 4 5 ON OFF • Chilled / heated ceiling and radiator / floor heating 1 2 3 4 5 ON OFF 3191S 11 N1 T B1 T B2 T D3 Y1 3191S 12 N1...