Siemens RDF302 - User Manual
Siemens RDF302 – User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Use
- Page 3 – switch; Note; -pipe fan coil unit
- Page 4 – Equipment combinations; -position actuators
- Page 5 – Mechanical design; The controller consists of 2 parts:; Operation and settings; Display
- Page 6 – Mounting and installation
- Page 7 – Disposal
- Page 9 – Connection terminals; Connection diagrams; YR
- Page 10 – Dimensions; Dimensions in mm; 008 Siemens Switzerland Ltd.
N3076en
11 July 2008
Building Technologies
3
076
RDF300, RDF300.02,
RDF340
RDF400.01
Semi Flush-mount
Room Temperature
Controllers with LCD
RDF300…
RDF340…
RDF400…
for 2-pipe, 2-pipe with el. heater and 4-pipe fan coil units
for use with compressors in DX type equipment
•
RDF300/RDF400 AC 230 V operating voltage, on/off or
3-position control outputs
•
RDF340… AC 24 V operating voltage, DC 0…10 V control outputs
•
Output for 3-speed or 1-speed fan
•
Two multifunctional inputs for keycard contact, external sensor, etc.
•
Operating modes: Comfort, Energy Saving and Protection
•
Automatic or manual heating/cooling changeover
•
Adjustable commissioning and control parameters
•
Minimum and maximum setpoint limitation
•
Mounting on recessed rectangular conduit box, 60.3 mm fixing centers
Additional RDF300.02 features
•
Backlit LCD
Additional RDF400.01 features
•
Backlit LCD
•
Infrared remote control receiver
•
Auto Timer mode with 8 programmable timers
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2/10 Siemens RDF300…/RDF340.../RDF400… Room Temperature Controllers N3076en Building Technologies 11 July 2008 Use To control the room temperature in individual rooms and zones that are: • Heated or cooled with 2-pipe fan coil units • Heated or cooled with 2-pipe fan coil units with electrical heate...
3/10 Siemens RDF300…/RDF340.../RDF400… Room Temperature Controllers N3076en Building Technologies 11 July 2008 Applications The controller supports following applications, which can be configured by DIP-switch on the inner side of the controller front panel. Depending on the type, on/off or modu-lat...
4/10 Siemens RDF300…/RDF340.../RDF400… Room Temperature Controllers N3076en Building Technologies 11 July 2008 Equipment combinations Type of unit Type reference Data Sheet Infrared remote control IRA210 3059 Cable temperature sensor QAH11.1 1840 Room temperature sensor QAA32 1747 Condensation detec...