Siemens Cooker hood – User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Table of Contents:
Page 2 – ELECTRO
Page 3 – When the extractor hood is operated; Operating modes; from
Page 4 – Repairs
Page 5 – Operating procedure; The most effective method of removing; Switch the ventilator ON; as soon as you begin cooking.; Switch the ventilator OFF; Press the corresponding button.; Filters and maintenance; Cleaning the metal grease filters:
Page 6 – Activated carbon filter:
Page 7 – Stainless steel surfaces:
Page 9 – Prior to installation; Exhaust air should neither be directed; which will be needed by the
Page 10 – Air connector
Page 11 – from specialist; Preparing the wall; The extractor hood; Electrical connection; Exhaust air
Page 12 – Installation; This extractor hood
Page 13 – Insert the other 4 screws with washers.; Before the 4 screws are tightened; Connect up the air outlet pipe.; Before tightening the 2 screws,; Avoid damage to the sensitive
Page 14 – Notes
Page 16 – Siemens-Electrogeräte GmbH; Family Line
Loading the manual
LC 75 . . LC 90 . .
LC 45 . .
Operating and installation instructions
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Page 2 - ELECTRO
Page 3 - When the extractor hood is operated; Operating modes; from
3 Appliance description Operating Instructions Operating modes Exhaust-air mode: ❑ The extractor-hood fan extracts the kit-chen vapours and conveys them throughthe grease filter into the atmosphere. ❑ The grease filter absorbs the solid particles in the kitchen vapours. ❑ The kitchen is kept almost ...
Page 4 - Repairs
4 Before using for the first time If you encounter a problem If you have any questions or if a faultoccurs, please call Customer Service. (See list of Customer Service representatives).When you call, please quote the following: E-Nr. FD Enter the relevant numbers into the boxabove. The E-Nr. (produc...
Page 5 - Operating procedure; The most effective method of removing; Switch the ventilator ON; as soon as you begin cooking.; Switch the ventilator OFF; Press the corresponding button.; Filters and maintenance; Cleaning the metal grease filters:
5 Operating procedure The most effective method of removing vapours produced during cooking is to: ❑ Switch the ventilator ON as soon as you begin cooking. ❑ Switch the ventilator OFF a few minutes after you have finishedcooking. Setting the required fan speed: ❑ Press the corresponding button. Ligh...
Page 6 - Activated carbon filter:
6 3. Insert the grease filters (see removal andinstallation of the metal-mesh greasefilters). Removing the filter: The filters are removed in reverse sequence. Replacing the activated carbon filters: ❑ During normal operation (1 to 2 hoursper day) the activated carbon filtersshould be replaced appro...
Page 7 - Stainless steel surfaces:
7 Replacing the light bulbs 1. Switch off the extractor hood and pullout the mains plug or switch off the electricity supply at the fuse box. 2. Remove the grease filters (see Filters andMaintenance). 3. Press down the bulb cover and disconnect from the light strip. 4. Replace the bulb (standard fil...
Page 9 - Prior to installation; Exhaust air should neither be directed; which will be needed by the
9 Prior to installation Exhaust-air mode The exhaust air is discharged upwardsthrough a ventilation shaft or directlythrough the outside wall into the open. D Exhaust air should neither be directed into a smoke or exhaust flue that iscurrently used for other purposes, nor intoa shaft that is used fo...
Page 10 - Air connector
10 Prior to installation ❑ Flat ducts must have an internal cross- section that equates to that of roundpipes. There should be no sharp bends. For operating in exhaust-air mode, a one-way flap should be mounted inside theextractor hood unless there is already onefitted in the outlet duct or wall ven...
Page 11 - from specialist; Preparing the wall; The extractor hood; Electrical connection; Exhaust air
11 Prior to installation Circulating-air mode ❑ With activated carbon filter if exhaust-airmode is not possible. The complete installation set can be obtained from specialist outlets. The corresponding accessory numbers canbe found at the end of these operatinginstructions. Preparing the wall ❑ The ...
Page 12 - Installation; This extractor hood
12 Installation This extractor hood is intended to be mounted onto the kitchen wall. 1. Remove the grease filter (refer to Operating Instructions). 2. Draw a line on the wall from the ceilingto the lower edge of the hood at thecentre of the location where the hood isgoing to be mounted. 3. Using the...
Page 13 - Insert the other 4 screws with washers.; Before the 4 screws are tightened; Connect up the air outlet pipe.; Before tightening the 2 screws,; Avoid damage to the sensitive
13 Installation 0 8. Insert the other 4 screws with washers. Before the 4 screws are tightened down, align the extractor hood properly. 0 9. Connect up the air outlet pipe. 10. Connect the hood to the electricitysupply. 13. Position the lower flue duct on theextractor hood and screw the extractorhoo...
Page 14 - Notes
Page 16 - Siemens-Electrogeräte GmbH; Family Line
9000 159 007 Printed in Germany 0306 Es. Siemens-Electrogeräte GmbH Family Line 018 0 5-2223 3 0,12/min. DTAG Siemens-Hausgeräte Besuchen Sie uns im Internet:http://www.siemens.de/hausgeraete