Roberts-Gordon NEMA 4 - Manual

Roberts-Gordon NEMA 4

Roberts-Gordon NEMA 4 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
Page: / 48

Table of Contents:

  • Page 3 – TABLE OF CONTENTS; SECTION 7: Commissioning The CORAYVAC
  • Page 5 – TABLE OF FIGURES
  • Page 7 – Design Requirements
  • Page 8 – URVSC: ULTRAVACTM Satellite Controller; ULTRAVACTM Controller
  • Page 9 – URVCCM: ULTRAVACTM Central Controller with Modem; Inside View
  • Page 10 – URVCCR: ULTRAVACTM Central Controller with RS-485 Converter; Power Supply
  • Page 11 – independent distrib-; Example Site Layout; is an example layout for a building
  • Page 12 – FIGURE 1: Example Site Layout
  • Page 14 – FIGURE 2: ROBERTS GORDON; Relay Board; Line Voltage 120 V wiring
  • Page 15 – Standard Models; Construction: 14 gauge painted steel, mounting; NEMA 4 Models; Vdc
  • Page 16 – Po; qu; Input Fuse Holder
  • Page 17 – SECTION 3: INSTALLATION; Installation of the ROBERTS GORDON; Positioning the ROBERTS GORDON; Choose a mounting location for the controller.; FIGURE 4: Controller Mounting; WARNING; Severe Injury Hazard
  • Page 18 – See Page 12, Figure 5; FIGURE 5: Indoor Sensor Cable Detail; See Page 12, Figure 6; Shield Wire
  • Page 19 – Electrical Installation Requirements; see; FIGURE 7: Variable Frequency Drive Mounting; DANGER; Electrical Shock Hazard
  • Page 20 – Indoor Sensor Placement; See Page 14, Figure 8; Outdoor Sensor Placement; If an outside air blower is to be used,
  • Page 21 – Description
  • Page 22 – FIGURE 11: ROBERTS GORDON
  • Page 23 – ROBERTS GORDON; VFD Power; Continued; Motor Power Supply
  • Page 24 – FIGURE 12: ROBERTS GORDON; ot Gr
  • Page 26 – SECTION 5: COMMUNICATIONS; See Page 25, Section; FIGURE 13: Modem Location; Modem
  • Page 27 – RS-485 Converter for Central Controller; and; nd Shield
  • Page 28 – For TCP/IP communication module wiring details,; FIGURE 15: TCP/IP Communication Module Mounting
  • Page 29 – FIGURE 16: TCP/IP Communication Module Wiring
  • Page 30 – FIGURE 17: 9 Pin Adapter for PC; Pin Adapter
  • Page 31 – Communications Between Multiple ROBERTS GORDON; Gro; Controller
  • Page 32 – ULTRAVACTM controller; FIGURE 19: Repeater Wiring
  • Page 33 – ULTRAVACTM; See
  • Page 34 – Using the procedure described in
  • Page 35 – SECTION 7: COMMISSIONING THE CORAYVAC; Record Frequency Setting Here:
  • Page 36 – FIGURE 20: End Vent Vacuum
  • Page 37 – FIGURE 21: Possible Damper Couplings’ Locations
  • Page 38 – on Page
  • Page 39 – ULTRAVACTM Controller Replacement Parts; Use only genuine ROBERTS GORDON; FIGURE 22: ROBERTS GORDON; Part Number
  • Page 40 – Variable Frequency Drive Replacement Parts; FIGURE 23: Variable Frequency Drive Components Diagram
  • Page 41 – Replacement Parts Instructions
  • Page 42 – Variable Frequency Drive 25 A or 10 A Fuse; ULTRAVACTM Controller. Turn
  • Page 45 – Ignition Module Diagnostic Codes:; un
  • Page 47 – SECTION 10: THE ROBERTS GORDON
Loading the manual

WARNING

Installation must be done by an electrician qualified

in the installation of control systems for heating

equipment.

Improper installation, adjustment, alteration, service

or maintenance can result in death, injury or property

damage. Read the Installation and Operation Manual

thoroughly before installing or servicing this

equipment.

Installer

Please take the time to read and understand

these instructions prior to any installation.

Installer must give a copy of this manual to the owner.

Owner

Keep this manual in a safe place in order to provide

your serviceman with necessary information.

Roberts-Gordon LLC

1250 William Street
P.O. Box 44
Buffalo, New York 14240-0044
Telephone: 716.852.4400
Fax: 716.852.0854
Toll Free: 800.828.7450

www.rg-inc.com

© 2008 Roberts-Gordon LLC

Quality in Any Language™

ROBERTS GORDON

®

UltraVac

Controls for

Modulating

CORAYVAC

®

Infrared Heating

Systems

Installation Manual

P/N 10081601NA Rev F 10/08

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - TABLE OF CONTENTS; SECTION 7: Commissioning The CORAYVAC

© 200 8 Ro b erts-Gordon LLC All rights reser v ed. N o part of this w ork co v ered b y the copyrights herein may b e reprod u ced or copied in any form or b y any means - graphic, electronic, or mechanical, incl u ding photocopying, recording, taping or information storage and retrie v al systems ...

Page 5 - TABLE OF FIGURES

TABLE OF FIGURES Figure 1: Example Site Layout .................................................. 6Figure 2: ROBERTS GORDON ® ULTRAVAC™ Controller Specifications ............................................................ 8 Figure 3: Variable Frequency Drive Components (Factory pre-wiring shown) .....

Page 7 - Design Requirements

SECTION 1: I NTRODUCTION 1 SECTION 1: INTRODUCTION1.1 What is ROBERTS GORDON ® ULTRAVAC™? The ROBERTS GORDON ® ULTRAVAC™ is a micro- processor based control package designed for modulating control of CORAYVAC ® heaters based on outdoor temperatures. This controller is capable of giving control outpu...

Other Roberts-Gordon Models

All Roberts-Gordon Other