Roberts-Gordon DAT100 - Manual
Roberts-Gordon DAT100 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 3 – TABLE OF CONTENTS; Performance Data - Graph of Air Flows v
- Page 5 – TABLE OF FIGURES; Type B
- Page 8 – * Halogenated Hydrocarbons; National Standards and Applicable Codes; CAUTION; Do not use heater in an area containing corrosive
- Page 9 – Figure 3
- Page 10 – WARNING; Figure 1; Free blowing DualAir
- Page 11 – Alternate; Side View
- Page 12 – General Technical Data Table; Reduce the maximum length stated by 1 m for each 90° bend installed.; Model
- Page 13 – Technical Data Table - Heater Section; Appliance Category II
- Page 14 – Performance Data - Graph of Air Flows v Static Pressure; Air Flow m
- Page 15 – Shelf Mounting and Suspension
- Page 17 – Refit the air intake spigot to the flexible hose re-; Inner Spigot
- Page 19 – Open Flued Installation; See Page 12, Figure 7; Heaters Installed Within the Heated Space; per kilowatt of total rated heat input and; Building Ventilation; and local and national; Isolated Equipment Rooms; See Page 13, Figure 9; Units Installed in Isolated Equipment Rooms; lue
- Page 21 – SECTION 9: GAS PIPING; ption
- Page 22 – Models; See Page 20, Section; k H
- Page 23 – DAT Main Circuit Board Terminal Identification
- Page 24 – DAT Wiring Diagram; SITE; For external fan wiring,
- Page 25 – DAT Wiring Diagram; Site wiring connections shown
- Page 26 – DAT Site Connections at Main Circuit Board
- Page 27 – Cooling Coils/Condensers; through Page; Mechanical Checks
- Page 28 – CLOSE; *Purge time begins at pressure switch change over.
- Page 29 – on; Check Gas Rate
- Page 31 – Heater Operation; See; Pull out for normal operation.; Red limit reset button; Press to reset
- Page 32 – on Page; Simple Fault Finding
- Page 34 – Motor
- Page 35 – Gas Control Valve Maintenance; See Page
- Page 36 – Burner Conversion; See Page 36, Section
- Page 37 – Start; Conduct Commissioning procedure as shown
- Page 38 – Troubleshooting For Automatic Ignition Burner Systems
- Page 39 – Troubleshooting for Flame Supervision System; START
- Page 41 – Troubleshooting for Fan Contactor; Conduct Commissioning procedure as
- Page 42 – SECTION 16: REMOVAL AND REPLACEMENT PARTS; See warnings and notes; Burner Components; See Page 5, Section 4; Figure 17: Standard Regulator Removal; . Once fitted follow commissioning; Remove Standard
- Page 43 – Burner Compartment; M ODEL
- Page 45 – Carry out a commission after working on or changing a flue fan.; M O DEL
- Page 46 – Heater Pressure Switch; grey; P re ssure S w itch; Colour Code
- Page 47 – Cooling Coil Safety Devices
- Page 48 – Fan Motor Removal; Disconnect the electrical connections at the; the same to ensure
- Page 50 – Figure 19: Combination Fan/Limit Thermostat
- Page 52 – Attach this information to the wall near the ROBERTS GORDON
WARNING
FOR YOUR SAFETY
If you smell gas:
1. Open windows.
2. DO NOT try to light any appliance.
3. DO NOT use electrical switches.
4. DO NOT use any telephone in
your building.
5. Leave the building.
6. Immediately call your local gas
supplier after leaving the building.
Follow the gas suppliers
instructions.
7. If you cannot reach your gas
supplier, call the Fire Department.
Fire Hazard
Do not store or use petrol or other
flammable vapours and liquids in the
vicinity of this or any other appliance.
Some objects will catch fire or explode
when placed close to heater.
Failure to follow these instructions can
result in death, injury or property
damage.
WARNING
Installation must be done by a registered installer/
contractor qualified in the installation and service
of gas-fired heating equipment or your gas supplier.
Improper installation, adjustment, alteration, service
or maintenance can result in death, injury or property
damage. Read the installation, operation and service
manual thoroughly before installing or servicing
this equipment.
Installer
Please take the time to read and understand
these instructions prior to any installation.
Installer must give a copy of this manual to the owner.
Owner
Keep this manual in a safe place in order to provide
your serviceman with necessary information.
© Copyright 2007 Roberts-Gordon, LLC
Quality in Any Language™
DualAir
®
Roberts-Gordon Europe Limited
Unit A, Kings Hill Business Park
Darlaston Road, Wednesbury
West Midlands WS10 7SH UK
Telephone: +44 (0)121 506 7700
Fax: +44 (0)121 506 7701
Service Telephone: +44 (0)190 249 8733
Service Fax: +44(0)190 240 1464
E-mail: [email protected]
E-mail: [email protected]
www.rg-inc.com
Installation, Commissioning,
Operation & Service Manual
DAT75
DAT90
DAT100
DAT115
P/N X527 Rev C 10/07
Heating and Cooling Units
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
© 2007 Roberts-Gordon, LLC All rights reserved. No part of this work covered by the copyrights herein may be reproduced or copied in any form or by any means - graphic, electronic, or mechanical, including photocopying, recording, taping or information storage and retrieval systems - without the wri...
TABLE OF FIGURES Figure 1: Condense Drain ......................................................... 3Figure 2: Installation Clearances and Clearances to Combustibles ............................................................. 4 Figure 3: Suspension Methods ............................................
D UAL A IR ® H EATING AND COOLING U NITS I NSTALLATION O PERATION AND S ERVICE M ANUAL 2 SECTION 1: HEATER SAFETY Your Safety is Important to Us!This symbol is used throughout the manual to notify you of possible fire, electrical or burn hazards. Please pay special attention when reading and followi...