Roberts-Gordon DAT100 - Manual

Roberts-Gordon DAT100

Roberts-Gordon DAT100 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
Page: / 52

Table of Contents:

  • Page 3 – TABLE OF CONTENTS; Performance Data - Graph of Air Flows v
  • Page 5 – TABLE OF FIGURES; Type B
  • Page 8 – * Halogenated Hydrocarbons; National Standards and Applicable Codes; CAUTION; Do not use heater in an area containing corrosive
  • Page 9 – Figure 3
  • Page 10 – WARNING; Figure 1; Free blowing DualAir
  • Page 11 – Alternate; Side View
  • Page 12 – General Technical Data Table; Reduce the maximum length stated by 1 m for each 90° bend installed.; Model
  • Page 13 – Technical Data Table - Heater Section; Appliance Category II
  • Page 14 – Performance Data - Graph of Air Flows v Static Pressure; Air Flow m
  • Page 15 – Shelf Mounting and Suspension
  • Page 17 – Refit the air intake spigot to the flexible hose re-; Inner Spigot
  • Page 19 – Open Flued Installation; See Page 12, Figure 7; Heaters Installed Within the Heated Space; per kilowatt of total rated heat input and; Building Ventilation; and local and national; Isolated Equipment Rooms; See Page 13, Figure 9; Units Installed in Isolated Equipment Rooms; lue
  • Page 21 – SECTION 9: GAS PIPING; ption
  • Page 22 – Models; See Page 20, Section; k H
  • Page 23 – DAT Main Circuit Board Terminal Identification
  • Page 24 – DAT Wiring Diagram; SITE; For external fan wiring,
  • Page 25 – DAT Wiring Diagram; Site wiring connections shown
  • Page 26 – DAT Site Connections at Main Circuit Board
  • Page 27 – Cooling Coils/Condensers; through Page; Mechanical Checks
  • Page 28 – CLOSE; *Purge time begins at pressure switch change over.
  • Page 29 – on; Check Gas Rate
  • Page 31 – Heater Operation; See; Pull out for normal operation.; Red limit reset button; Press to reset
  • Page 32 – on Page; Simple Fault Finding
  • Page 34 – Motor
  • Page 35 – Gas Control Valve Maintenance; See Page
  • Page 36 – Burner Conversion; See Page 36, Section
  • Page 37 – Start; Conduct Commissioning procedure as shown
  • Page 38 – Troubleshooting For Automatic Ignition Burner Systems
  • Page 39 – Troubleshooting for Flame Supervision System; START
  • Page 41 – Troubleshooting for Fan Contactor; Conduct Commissioning procedure as
  • Page 42 – SECTION 16: REMOVAL AND REPLACEMENT PARTS; See warnings and notes; Burner Components; See Page 5, Section 4; Figure 17: Standard Regulator Removal; . Once fitted follow commissioning; Remove Standard
  • Page 43 – Burner Compartment; M ODEL
  • Page 45 – Carry out a commission after working on or changing a flue fan.; M O DEL
  • Page 46 – Heater Pressure Switch; grey; P re ssure S w itch; Colour Code
  • Page 47 – Cooling Coil Safety Devices
  • Page 48 – Fan Motor Removal; Disconnect the electrical connections at the; the same to ensure
  • Page 50 – Figure 19: Combination Fan/Limit Thermostat
  • Page 52 – Attach this information to the wall near the ROBERTS GORDON
Loading the manual

WARNING

FOR YOUR SAFETY

If you smell gas:

1. Open windows.

2. DO NOT try to light any appliance.

3. DO NOT use electrical switches.

4. DO NOT use any telephone in

your building.

5. Leave the building.

6. Immediately call your local gas

supplier after leaving the building.

Follow the gas supplier’s

instructions.

7. If you cannot reach your gas

supplier, call the Fire Department.

Fire Hazard

Do not store or use petrol or other

flammable vapours and liquids in the

vicinity of this or any other appliance.

Some objects will catch fire or explode

when placed close to heater.

Failure to follow these instructions can

result in death, injury or property

damage.

WARNING

Installation must be done by a registered installer/

contractor qualified in the installation and service

of gas-fired heating equipment or your gas supplier.

Improper installation, adjustment, alteration, service

or maintenance can result in death, injury or property

damage. Read the installation, operation and service

manual thoroughly before installing or servicing

this equipment.

Installer

Please take the time to read and understand

these instructions prior to any installation.

Installer must give a copy of this manual to the owner.

Owner

Keep this manual in a safe place in order to provide

your serviceman with necessary information.

© Copyright 2007 Roberts-Gordon, LLC

Quality in Any Language™

DualAir

®

Roberts-Gordon Europe Limited

Unit A, Kings Hill Business Park
Darlaston Road, Wednesbury
West Midlands WS10 7SH UK
Telephone: +44 (0)121 506 7700
Fax: +44 (0)121 506 7701
Service Telephone: +44 (0)190 249 8733
Service Fax: +44(0)190 240 1464
E-mail: [email protected]
E-mail: [email protected]

www.rg-inc.com

Installation, Commissioning,

Operation & Service Manual

DAT75
DAT90

DAT100
DAT115

P/N X527 Rev C 10/07

Heating and Cooling Units

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - TABLE OF CONTENTS; Performance Data - Graph of Air Flows v

© 2007 Roberts-Gordon, LLC All rights reserved. No part of this work covered by the copyrights herein may be reproduced or copied in any form or by any means - graphic, electronic, or mechanical, including photocopying, recording, taping or information storage and retrieval systems - without the wri...

Page 5 - TABLE OF FIGURES; Type B

TABLE OF FIGURES Figure 1: Condense Drain ......................................................... 3Figure 2: Installation Clearances and Clearances to Combustibles ............................................................. 4 Figure 3: Suspension Methods ............................................

Page 8 - * Halogenated Hydrocarbons; National Standards and Applicable Codes; CAUTION; Do not use heater in an area containing corrosive

D UAL A IR ® H EATING AND COOLING U NITS I NSTALLATION O PERATION AND S ERVICE M ANUAL 2 SECTION 1: HEATER SAFETY Your Safety is Important to Us!This symbol is used throughout the manual to notify you of possible fire, electrical or burn hazards. Please pay special attention when reading and followi...

Other Roberts-Gordon Models

All Roberts-Gordon Other