Roberts-Gordon 175 - Manual

Roberts-Gordon 175

Roberts-Gordon 175 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
Page: / 48

Table of Contents:

  • Page 3 – TABLE OF CONTENTS; SECTION 16: The ROBERTS GORDON
  • Page 5 – TABLE OF FIGURES; Figure 1: Installation Clearances and Clearances to
  • Page 7 – SECTION 1: HEATER SAFETY; Your Safety is Important to Us!; Manpower Requirements
  • Page 8 – SECTION 2: INSTALLER RESPONSIBILITY; through Page; Corrosive Chemicals; CAUTION; Do not use heater in an area containing corrosive; * Halogenated Hydrocarbons; National Standards and Applicable Codes
  • Page 9 – Figure 2
  • Page 10 – WARNING; Fire Hazard; COMBAT; Clearances to Combustibles; Wall; Top; Installation Clearances; combustion concentric; * Recommended mounting height varies with heater input.
  • Page 11 – SECTION 4: NATIONAL STANDARDS AND APPLICABLE CODES; , local ordinances and any special
  • Page 12 – SECTION 5: MAJOR COMPONENTS; Heaters are designed for installation above 6'; Crush Hazard; Figure 2: Suspension Methods
  • Page 13 – and; Vent Installation; Figure 8
  • Page 14 – See Page 12, Figure 8; Unvented Operation; Combustion by-products contain a; Horizontal Venting; In noncombustible walls only, vent terminal; Length Requirements
  • Page 15 – Figure 3: Vent and Roof Detail; Vertical
  • Page 16 – TOP VIEW
  • Page 17 – Figure 7: Concentric Vent Box; qu
  • Page 18 – Figure 8: Concentric Vertical and Horizontal Vent Termination; Vent; - Separated Combustion Heater
  • Page 19 – SECTION 7: AIR SUPPLY; Building Ventilation; Follow the constraints listed
  • Page 20 – SECTION 8: GAS PIPING; To reduce
  • Page 21 – Electrical Shoc; Positioning Thermostats; A room thermostat or ROBERTS GORDON; Low Voltage Thermostat with One Heater
  • Page 24 – Electrical Connection to the Heater; Junction box is not provided with heater.
  • Page 25 – SECTION 10: OPERATION AND MAINTENANCE
  • Page 26 – Figure 10: Automatic Burner Control Sequence; Burner Sequence for Ignition Control; *Purge time begins at pressure switch change over.; Top Vie
  • Page 27 – on; Check Gas Rate
  • Page 28 – Electrical Shock Hazard; LED INDICATION FAULT MODE
  • Page 30 – through
  • Page 31 – Maintenance Checklist; Installation Code and Annual Inspections:; See Page 3, Section 3; Heat Exchanger; See Page 14, Section 8
  • Page 32 – Thermostat
  • Page 33 – SECTION 13: TROUBLESHOOTING; Start
  • Page 34 – Troubleshooting For Automatic Ignition Burner Systems; Conduct start-up procedure as shown; on Page
  • Page 35 – Troubleshooting for Flame Supervision System; START
  • Page 36 – Troubleshooting for Gas Valves; Troubleshooting for Combustion Fan
  • Page 37 – SECTION 14: REPLACEMENT PARTS; See
  • Page 38 – Burner Compartment; Unscrew; Burner Injectors; MODEL
  • Page 39 – Ignition Electrode and Flame Probe; front view of the burner compartment.
  • Page 40 – Combustion Fan Vertical Installation; Refit in reverse order.; Carry out a start-up after working on or changing a combustion fan.
  • Page 41 – See Page 19, Section
  • Page 42 – Ignition Control; Remove the screws; and Replacement
  • Page 43 – SECTION 15: SPECIFICATIONS; Rear View
  • Page 45 – SECTION 16: THE ROBERTS GORDON
  • Page 48 – Attach this information to the wall near the ROBERTS GORDON
Loading the manual

Installation, Operation

& Service Manual

Models UHA[S]

150, 175, 200, 225
250, 300, 350, 400

P/N 111101NA 10/07 Rev. D

UHA-Series

Tubular Unit Heaters

(Standard Range)

WARNING

FOR YOUR SAFETY

If you smell gas:

1. Open windows.

2. DO NOT try to light any appliance.

3. DO NOT use electrical switches.

4. DO NOT use any telephone in

your building.

5. Leave the building.

6. Immediately call your local gas

supplier after leaving the building.

Follow the gas supplier’s

instructions.

7. If you cannot reach your gas

supplier, call the Fire Department.

Fire Hazard

Do not store or use gasoline or other

flammable vapors and liquids in the

vicinity of this or any other appliance.

Some objects will catch fire or explode

when placed close to heater.

Failure to follow these instructions can

result in death, injury or property

damage.

WARNING

Installation must be done by a contractor qualified

in the installation and service of gas-fired heating

equipment or your gas supplier.

Improper installation, adjustment, alteration, service

or maintenance can result in death, injury or property

damage. Read the Installation, Operation and Service

Manual thoroughly before installing or servicing

this equipment.

Installer

Please take the time to read and understand

these instructions prior to any installation.

Installer must give a copy of this manual to the owner.

Owner

Keep this manual in a safe place in order to provide

your serviceman with necessary information.

Roberts-Gordon, LLC

1250 William Street
P.O. Box 44
Buffalo, New York 14240-0044
Telephone: 716.852.4400
Fax: 716.852.0854
Toll Free: 800.828.7450

www.rg-inc.com

© Copyright 2007 Roberts-Gordon, LLC

Quality in Any Language™

Combat

®

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - TABLE OF CONTENTS; SECTION 16: The ROBERTS GORDON

© 2007 Roberts-Gordon, LLC All rights reserved. No part of this work covered by the copyrights herein may be reproduced or copied in any form or by any means - graphic, electronic, or mechanical, including photocopying, recording, taping or information storage and retrieval systems - without the wri...

Page 5 - TABLE OF FIGURES; Figure 1: Installation Clearances and Clearances to

TABLE OF FIGURES Figure 1: Installation Clearances and Clearances to Combustibles ............................................................. 4 Figure 2: Suspension Methods ................................................. 6Figure 3: Vent and Roof Detail ..............................................

Page 7 - SECTION 1: HEATER SAFETY; Your Safety is Important to Us!; Manpower Requirements

SECTION 1: H EATER S AFETY 1 SECTION 1: HEATER SAFETY Your Safety is Important to Us! This symbol is used throughout the manual to notify you of possible fire, electrical or burn hazards. Please pay special attention when reading and following the warnings in these sections.Installation, Service and...

Other Roberts-Gordon Models