Page 2 - Thank-you for purchasing a; REGENCY FIREPLACE PRODUCT.
Regency Freestanding Woodstove 2 Thank-you for purchasing a REGENCY FIREPLACE PRODUCT. The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you haveany questions about your product that are not covered in this manual, please contact the R...
Page 3 - TABLE OF CONTENTS; THE REGENCY FREESTANDING STOVE; Optional Accessories; OPERATING INSTRUCTIONS; SAFETY LABEL; INSTALLATION; Listed Components for Mobile Home Installation
Regency Freestanding Woodstove 3 TABLE OF CONTENTS THE REGENCY FREESTANDING STOVE Door Handle ...................................................................... 1 7 Glass Installation .............................................................. 1 7 Optional Accessories - Pedestal Ash Drawer Ki...
Page 4 - HOT WHILE IN OPERATION DO NOT TOUCH. KEEP CHILDREN,; CAUTION; TE OF MANUF
Regency Freestanding Woodstove 4 HOT WHILE IN OPERATION DO NOT TOUCH. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS. READ NAMEPLATE AND INSTRUCTIONS. DO NOT REMOVE THIS LABEL FLOOR PROTECTION* F1100S WITH AIRMATE SHIELD LISTED SPACE HEATER, SOLID FUEL TYPE, ALSOSUITABLE FO...
Page 9 - RESIDENTIAL; ROOM AIR; Modular Part; Airmate OR; Things to consider when choosing options
Regency Freestanding Woodstove 9 INSTALLATION RESIDENTIAL INSTALLATION 1 ) Read all instructions before installing your Regency Stove. Install and use only inaccordance with these installation andoperating instructions. Be aware that localCodes and Regulations may override someitems in this manual. ...
Page 10 - MINIMUM CLEARANCE TO; Residential Installation “C” Vent (Single Wall)
Regency Freestanding Woodstove 10 INSTALLATION MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS Please read the section below carefully as clearances depend on whether the airmate or therear heat deflector is installed on the stove. Measurements "From Unit" are from the top plate of the stove to a...
Page 11 - Minimum Alcove Clearance to Combustible Materials; Floor Protection
Regency Freestanding Woodstove 11 Minimum Alcove Clearance to Combustible Materials The Regency Freestanding models have been alcove approved and must be installedwith a listed double wall connector to the ceiling level. Note: Minimum alcove ceiling height - 84" Maximum depth of alcove - 36"...
Page 12 - STOVE ASSEMBLY; Airmate Assembly for F1100,; Rear Heat Deflector Assembly for
Regency Freestanding Woodstove 12 INSTALLATION Diagram 4 Diagram 2 Diagram 3 STOVE ASSEMBLY PRIOR TO INSTALLATION All units require either the pedestal or 4 legsattached to the base. The F1100, F2100, andF3100 stoves require either the Airmate or RearHeat Deflector on top of the stove. Clearancesto ...
Page 13 - Leg and Bottom Shield Assembly; STEP BY STEP
Regency Freestanding Woodstove 13 Horizontal Installation Standard Ceiling Installation 8 ) To complete your chimney installation, in- stall the double wall connector pipe fromthe stove’s flue collar to the chimney sup-port device. 9 ) If you are using a horizontal connector, the chimney connector s...
Page 14 - TABLE 1; MOBILE HOME INSTALLATION
Regency Freestanding Woodstove 14 INSTALLATION TABLE 1 MINIMUM RECOMMENDED FLUE HEIGHTS IN FEET (Measured from the top of the unit) # OF ELBOWS ELEVATION (FT) ABOVE SEA LEVEL 0 2 x 15 o 4 x 15 o 2 x 30 o 4 x 30 o 2 x 45 o 4 x 45 o 0-1000 12.0 13.0 14.0 15.0 18.0 16.0 20.0 1000-2000 12.5 13.5 14.5 15...
Page 15 - Canadian Installations*; SECONDARY AIR TUBE
Regency Freestanding Woodstove 15 Large Stoves F3100L and S3100L The unit arrives with the first two air tubes (fromthe front) and the 2 baffle bricks on the floor ofthe firebox. The baffle bricks are positionedfirst and then the air tubes are installed. NOTE: If the first 2 airtubes are already ins...
Page 16 - Medium Stoves
Regency Freestanding Woodstove 16 INSTALLATION Side View Front View Front View Side View Front View Front View 3 ) Tilt the left baffle brick up on top of the side channel and it will leave enough room toposition the right baffle brick in the samemanner as Step 1) above. Then repositionthe left baff...
Page 17 - OPTIONAL; DOOR HANDLE; Bottom Shield Ash Drawer Kit; BRICK INSTALLATION
Regency Freestanding Woodstove 17 OPTIONAL ACCESSORIES The pieces listed below can be purchased andinstalled during the initial installation or added onlater. Freestanding - Medium F2100 & S2100 Freestanding - Large F3100 DOOR HANDLE Attach spring handle by rotating counter clock-wise onto rod. ...
Page 18 - WARNING: Electrical Grounding Instructions
Regency Freestanding Woodstove 18 Blower/Fan (846-515) 1 ) Remove the two screws from the top of the fan housing. 2 ) Slide the fan up into the rear heat shield. 3 ) After aligning holes, secure the fan to the rear heat shield using the two screwsremoved earlier. Note: The connection cord should not...
Page 19 - OPERATING
Regency Freestanding Woodstove 19 OPERATING INSTRUCTIONS 4 ) After about 15 to 20 minutes, when your wood has begun to burn strongly, adjustyour draft control down to keep the fire ata moderate level. WARNING: Never build a roaring fire ina cold stove. Always warm yourstove up slowly! 5 ) Once a bed...
Page 20 - ASH DISPOSAL; Safety Precautions; SAFETY GUIDELINES; MAINTENANCE
Regency Freestanding Woodstove 20 ASH DISPOSAL During constant use, ashes should be removedevery few days. The Ash Drawer option fea-tures a convenient ash dump for easy removalof ash, see "Modular Options" on page 9. Safety Precautions 1 ) Do not allow ashes to build up to the loading doors...
Page 21 - CREOSOTE; Ways to Prevent and Keep Unit; MAINTENANCE OF; Glass Replacement
Regency Freestanding Woodstove 21 MAINTENANCE CREOSOTE When wood is burned slowly, it produces tarand other organic vapours, which when com-bined with moisture, form creosote. The creo-sote vapours condense in the relatively coolchimney flue of a slow burning fire. As a result,creosote residue accum...
Page 22 - PARTS LIST
Regency Freestanding Woodstove 22 PARTS LIST 1 ) 846-913 Door Assy-Sm/Med Gold F1100 (no glass) 846-915 Door Assy-Sm/Med Black F1100 (no glass) 846-910 Door Assy-Large Gold F3100 (no glass) 846-916 Door Assy-Large Black F3100 (no glass) 3 ) 846-302 Glass - Replacement - Small/Medium F1100 846-304 Gl...
Page 26 - FIREBRICK
Regency Freestanding Woodstove 26 70) 902-111 Brick - Regular Full Size: 1-1/4" x 4-1/2" x 9" 71) 802-104 Brick Partial: 1-1/4" x 4" x 9" 72) 802-122 Brick Partial: 1-1/4" x 2" x 4-1/2" 73) 802-146 Brick Partial: 1-1/4" x 1-3/4" x 9" 74) 802-147 Brick ...
Page 27 - WARRANTY
Regency Freestanding Woodstove 27 WARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality AssuranceTeam carefully inspects each unit thoroughly before it leaves our door. Regency Industries Ltd. is pleased to extend this limitedlife...
Page 28 - Installer: Please complete the following information; Printed in Canada
Installer: Please complete the following information Dealer Name & Address: ______________________________________________ __________________________________________________________________ Installer: ___________________________________________________________ Phone #: __________________________...