Page 2 - designed to provide you with all the warmth and charm of a wood; MANUFACTURED MOBILE HOME REQUIREMENTS; INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE; This Regency
Regency ® P40-1 Direct Vent Gas Fireplace 2 To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY ® . The P40 has been designed to provide you with all the warmth and charm of a wood fi replace at the fl ick of a switch. The model P40 has been approved b...
Page 3 - TABLE OF CONTENTS
Regency ® P40-1 Direct Vent Gas Fireplace 3 TABLE OF CONTENTS Conversion Kit #502-969 from NG to LP ..................... 27Conversion Kit #502-966 from LP to NG ..................... 29Brick Panel Installation ................................................ 31Aeration Adjustment .....................
Page 4 - INSTALLATION
Regency ® P40-1 Direct Vent Gas Fireplace 4 INST ALLA TION INSTALLATION This is a copy of the label that accompanies each P40-NG1 and P40-LP1 Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review. NOTE: Regency ® units are constantly being improved. Check the label o...
Page 5 - INST; MA Code - CO Detector
Regency ® P40-1 Direct Vent Gas Fireplace 5 INST ALLA TION INSTALLATION 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.3 by adding the following additional requirements: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used...
Page 6 - Dimensions
Regency ® P40-1 Direct Vent Gas Fireplace 6 INST ALLA TION INSTALLATION 34" (864mm) 40” (1016mm) 8” (203mm) Outer Dia. 5” (127mm) Inner Dia. 40” (1016mm) 35-7/8” (889mm) 35-1/4" (895mm) 20-1/16” (508mm) Dimensions
Page 8 - Floor Mounted Fireplace
Regency ® P40-1 Direct Vent Gas Fireplace 8 INST ALLA TION INSTALLATION HEARTH REQUIREMENTS A 40" (1016mm) wide x 16" (406mm) deep x 1-1/2" (38mm) thick hearth is required, unless the unit is raised 4" (102mm). 4) This appliance is Listed for bedroom installations when used with the ...
Page 9 - CLEARANCES; Clearance to Combustibles from:
Regency ® P40-1 Direct Vent Gas Fireplace 9 INST ALLA TION INSTALLATION CLEARANCES The clearances listed below are minimum distances unless otherwise stated: A major cause of chimney related fi res is failure to maintain required clearances (air space) to combustible materials. It is of the greatest...
Page 10 - to floor; MANTEL CLEARANCES; Fireplace; MANTEL LEG CLEARANCES; Allowable mantel leg; Fireplace; Full Screen Door
Regency ® P40-1 Direct Vent Gas Fireplace 10 INST ALLA TION INSTALLATION 13” Mantel 8” Mantel 1” Mantel 33” to floor 2 0 12 14 6 4 8 10 17” 21” 2 0 12 6 16 18 20 4 14 8 10 Combustible Material Top Standoff Non-CombustibleHeader (On Edge) Side View TopLouvers 12” 8-1/2” 10-1/4” TopNailingStrip Non-Co...
Page 11 - Header; Non-Combustible Studs; The; FULL SCREEN DOOR
Regency ® P40-1 Direct Vent Gas Fireplace 11 INST ALLA TION INSTALLATION 10-1/4” Above Fireplace 6” 6” Diagram 1 1) Frame in the enclosure for the unit with framing material. The framed opening for the assembled kit is 42-1/2" high x 40-1/2" wide x 20-1/16" deep (1080mm H x 1029mm W x 50...
Page 12 - VENTING INTRODUCTION; UNIT ASSEMBLY PRIOR TO; TOP STANDOFF ASSEMBLY; TOP FACING SUPPORT AND SIDE NAILING STRIPS; VENT RESTRICTOR POSITION
Regency ® P40-1 Direct Vent Gas Fireplace 12 INST ALLA TION INSTALLATION VENTING INTRODUCTION The P40 uses the "balanced fl ue" technology Co Axial system. The inner liner vents products of combustion to the outside while the outer liner draws outside combustion air into the combustion chamb...
Page 13 - EXTERIOR VENT TERMINATION REQUIREMENTS
Regency ® P40-1 Direct Vent Gas Fireplace 13 INST ALLA TION INSTALLATION EXTERIOR VENT TERMINATION REQUIREMENTS A= Clearance above grade, veranda, porch, deck, or balcony *(min. 12"/30cm) B= Clearance to window or door that may be opened *(12"/30cm) #(9"/23cm) C= Clearance to permanently...
Page 14 - VENTING ARRANGEMENTS; Regency; Flue pipe
Regency ® P40-1 Direct Vent Gas Fireplace 14 INST ALLA TION INSTALLATION VENTING ARRANGEMENTS HORIZONTAL TERMINATION (FLEX) Regency ® Direct Vent System These venting systems, in combination with the P40 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Warnock...
Page 15 - RIGID PIPE VENTING SYSTEMS; BASIC HORIZONTAL & VERTICAL TERMINATIONS; AstroCap XL; Alternate
Regency ® P40-1 Direct Vent Gas Fireplace 15 INST ALLA TION INSTALLATION RIGID PIPE VENTING SYSTEMS BASIC HORIZONTAL & VERTICAL TERMINATIONS Rigid Pipe Vent Systems offer a complete line of component parts for installation of both horizontal and vertical installations. Many items are offered in ...
Page 16 - ” X 8” RIGID PIPE CROSS REFERENCE CHART
Regency ® P40-1 Direct Vent Gas Fireplace 16 INST ALLA TION INSTALLATION Description Simpson Direct Vent Pro ® Simpson Direct Vent GS ® Discontinued Selkirk Direct-Temp™ Metal-Fab ® Sure Seal 6” Pipe Length, Galvanized 58DVA-06 1208 5DT-6 5D6 6” Pipe Length, Black 58DVA-06B 1208B 5DT-6B 5D6B 9” Pipe...
Page 17 - Offset Pipe Selection:; Use this table to determine offset pipe lengths.
Regency ® P40-1 Direct Vent Gas Fireplace 17 INST ALLA TION INSTALLATION L676 & L900 Direct Vent Fireplace IMPORTANT NOTE • A Vent Guard is required when the AstroCap is installed above grade at 7 feet or lower.• The Simpson Dura-Vent and Selkirk Direct Temp horizontal termination caps cannot be...
Page 18 - ALLOWABLE HORIZONTAL TERMINATIONS; ertical
Regency ® P40-1 Direct Vent Gas Fireplace 18 INST ALLA TION INSTALLATION The diagram shows all allowable combinations of vertical runs with horizontal terminations, one 90 o elbow (two 45 o elbows equal one 90 o elbow). Note: Must use optional rigid pipe adapter (Part # 770-994) when using any Rigid...
Page 19 - Elbows; Option V
Regency ® P40-1 Direct Vent Gas Fireplace 19 INST ALLA TION INSTALLATION H H1 V Horizontal Venting with Two (2) 90 o Elbows Horizontal Venting with Three (3) 90 o Elbows One 90 o elbow = Two 45 o elbows. One 90 o elbow = Two 45 o elbows. Option V H + H1 A) 2' Min. 2' Max. B) 3' Min. 5' Max. C) 4' Mi...
Page 20 - Option V
Regency ® P40-1 Direct Vent Gas Fireplace 20 INST ALLA TION INSTALLATION V H1 H V1 V1 V H Vertical Venting with Two (2) 90 o Elbows Vertical Venting with Three (3) 90 o Elbows One 90 o elbow = Two 45 o elbows. One 90 o elbow = Two 45 o elbows. Option V H V + V1 A) 0' Min. 2' Max. 1' Min. B) 1' Min. ...
Page 21 - ALLOWABLE VERTICAL TERMINATIONS
Regency ® P40-1 Direct Vent Gas Fireplace 21 INST ALLA TION INSTALLATION • Vent must be supported at offsets.• Firestops are required at each fl oor level and whenever passing through a wall. • Maintain clearances to combustibles as listed in the "Clearances" section. • Refer to "Vent Re...
Page 22 - UNIT INSTALLATION
Regency ® P40-1 Direct Vent Gas Fireplace 22 INST ALLA TION INSTALLATION Diagram 7 Diagram 6 10) Install wall thimble in the center of the 11" (279mm) square and attach with wood screws (Diagram 7). Diagram 5 7) Insure that the 1-1/4"(32mm) pipe clearances to combustible materials are mainta...
Page 23 - Offset Chart
Regency ® P40-1 Direct Vent Gas Fireplace 23 INST ALLA TION INSTALLATION 6) Continue to assemble pipe lengths. Note: If an offset is necessary in the attic to avoid obstructions, it is important to support the vent pipe every 3 feet (0.9 meter), to avoid excessive stress on the elbows, and possible ...
Page 24 - HORIZONTAL TERMINATION; Do not locate termination; ASTROCAP XL
Regency ® P40-1 Direct Vent Gas Fireplace 24 INST ALLA TION INSTALLATION 4) Separate the 2 halves of the wall thimble and securely fasten the one with the tabs to the outside wall making sure that the tabs are on top and bottom. Fasten the other thimble half to the inside wall. The thimble halves sl...
Page 25 - PILOT ADJUSTMENT; HIGH ELEVATION
Regency ® P40-1 Direct Vent Gas Fireplace 25 INST ALLA TION INSTALLATION P40-NG1 SYSTEM DATA For 0 to 4500 feet altitude Front Burner Ori fi ce: #44 Back Burner Ori fi ce: #35 Max. Input Rating 4 5 , 0 0 0 B t u / h Min. Input Rating 13,000 Btu/h Supply Pressure min.5.0" w.c. Manifold Pressure (...
Page 26 - GAS PIPE PRESSURE; SIT VALVE DESCRIPTION
Regency ® P40-1 Direct Vent Gas Fireplace 26 INST ALLA TION INSTALLATION GAS PIPE PRESSURE TESTING The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to o...
Page 27 - THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
Regency ® P40-1 Direct Vent Gas Fireplace 27 INST ALLA TION INSTALLATION CONVERSION KIT #502-969 FROM NG TO LP LP Conversion Kit Contains:Qty. Part # Description 1 910-462 LP Conversion Coil 1 910-037 LP Pilot Orifi ce 1 904-345 Orifi ce #53 1 904-575 Orifi ce #55 1 904-529 Allen Key 1 918-590 LP Co...
Page 28 - These instructions must be left
Regency ® P40-1 Direct Vent Gas Fireplace 28 INST ALLA TION INSTALLATION 14) Re-install pilot shield. 15) Set aeration on both front and rear burner for LP gas; Rear 3/16" Front 3/8" 16) Reverse steps 8 to 4. 17) Remove the Power Module by lifting it up off of the velcro and move it over to ...
Page 31 - IMPORTANT; BRICK PANEL INSTALLATION; Must install 1 set of brick panels with the P40.
Regency ® P40-1 Direct Vent Gas Fireplace 31 INST ALLA TION INSTALLATION IMPORTANT Dangerous operating conditions may occur if the panels are broken. 1) Unwrap the Brick Panels from the protective wrapping. 2) Ensure that the logs are not in the unit. 3) Place the 2 small Back Brick Panels at the ba...
Page 32 - LOG SET INSTALLATION
Regency ® P40-1 Direct Vent Gas Fireplace 32 INST ALLA TION INSTALLATION Read the instructions below carefully and refer to the pictures. If the logs are broken do not use the unit until they are replaced. Broken logs can interfere with the pilot operation. Log kit (Part # 503-930) contains the foll...
Page 35 - Completed Log Set Installation
Regency ® P40-1 Direct Vent Gas Fireplace 35 INST ALLA TION INSTALLATION Completed Log Set Installation 03-37 03-36 03-46 03-34 03-32 03-47 03-40 03-38(1) 03-38(2) 16) Place one of log 03-38 on the exposed base brick on the left side of the unit as shown. 17) Place the second piece of log 03-38 on t...
Page 36 - STANDARD; FLUSH LOUVERS
Regency ® P40-1 Direct Vent Gas Fireplace 36 INST ALLA TION INSTALLATION Diagram 1 Diagram 3 STANDARD FLUSH DOOR NOTE: Install Finishing Trim prior to installing the Flush Door and Louvers. 1) The standard fl ush door comes with a black frame. To install the frame, simply hook the top door fl ange o...
Page 37 - WIRING DIAGRAM
Regency ® P40-1 Direct Vent Gas Fireplace 37 INST ALLA TION INSTALLATION WIRING DIAGRAM CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. A receptacle is provided on the left hand side of the unit. 120 Volt AC power mus...
Page 38 - Full Screen Door Frame Installation; FULL SCREEN DOORS
Regency ® P40-1 Direct Vent Gas Fireplace 38 INST ALLA TION INSTALLATION Leave these two screws secured Remove the center screw Loosen these four screws Leave these two screws secured Cut Outs Oblong Hole Top Flange Bottom Flange Cut Outs Rear view of Full Screen Door Frame Shown Inside Top of Outer...
Page 40 - OPERATING INSTRUCTIONS
Regency ® P40-1 Direct Vent Gas Fireplace 40 OPERA TION OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS 1) Read and understand these instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock. 3) Check to ensure there are no gas leak...
Page 41 - HOT; FIRST FIRE
Regency ® P40-1 Direct Vent Gas Fireplace 41 OPERA TION OPERATING INSTRUCTIONS During the fi rst few fi res, a white fi lm may develop on the glass front as part of the curing process. The glass should be cleaned after the unit has cooled down or the fi lm will bake on and become very dif fi cult to...
Page 42 - For the Manual Control Box, located on
Regency ® P40-1 Direct Vent Gas Fireplace 42 OPERA TION OPERATING INSTRUCTIONS SUMMARY OF CONTROLS For the Manual Control Box, located on right hand side of the bottom louver. On/Off Button If the unit is off, pressing and releasing this button once will switch the unit on. The unit will be on high ...
Page 43 - OPERA; COPY OF LIGHTING PLATE INSTRUCTIONS; TO TURN OFF GAS APPLIANCE; DO NOT REMOVE THIS INSTRUCTION PLATE
Regency ® P40-1 Direct Vent Gas Fireplace 43 OPERA TION OPERATING INSTRUCTIONS COPY OF LIGHTING PLATE INSTRUCTIONS TO TURN OFF GAS APPLIANCE FOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS 1) Push in gas control knob slightly and turn clockwise to “OFF”. Knob cannot be turned from “PILOT”...
Page 44 - MAINTENANCE
Regency ® P40-1 Direct Vent Gas Fireplace 44 MAINTENANCE MAINTENANCE MAINTENANCE INSTRUCTIONS 1) Always turn off the gas valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year. When cleaning ...
Page 45 - DOOR GLASS; GLASS REPLACEMENT; FAN REPLACEMENT
Regency ® P40-1 Direct Vent Gas Fireplace 45 MAINTENANCE MAINTENANCE C A U T I O N : We a r g l o v e s w h e n r e m o v i n g d a m a g e d o r b r o k e n glass. WARNING: Do not operate the appliance with the glass panels removed, cracked or broken. Replacement of the glass panels should be done ...
Page 46 - VALVE REPLACEMENT
Regency ® P40-1 Direct Vent Gas Fireplace 46 MAINTENANCE MAINTENANCE VALVE REPLACEMENT 1) Shut off the main gas supply and unplug the power to the ECS system. 2) Remove the main gas line pipe from the gas valve. 3) Remove logs and brick panels if installed. 4) Remove the log stand by undoing the 2 s...
Page 47 - DC SPARKER; POWER MODULE
Regency ® P40-1 Direct Vent Gas Fireplace 47 MAINTENANCE MAINTENANCE 1) Unplug the power source. 2) Remove the manual control panel by removing the 2 screws. 3) Remove the DC Sparker by removing the 2 screws that secure the DC Sparker to the fi rebox and lift out. DC Sparker 4) Remove the cover on t...
Page 48 - CONTROL MODULE; BACKUP BATTERY
Regency ® P40-1 Direct Vent Gas Fireplace 48 MAINTENANCE MAINTENANCE Power Module 3) Remove the Control Module by lifting it up off of the velcro and pull out. 1) Unplug the power source. 2) Remove the Power Module by lifting it up off of the velcro and pull out. Control Module 4) Remove the Heat Sh...
Page 49 - TS LIST; PARTS LIST; MAIN ASSEMBLY
Regency ® P40-1 Direct Vent Gas Fireplace 49 P A R TS LIST PARTS LIST MAIN ASSEMBLY Part # Description 10) 502-528 Brick Panel Base (Set of 3) 502-901 Brick Panel Set Standard Brown 502-902 Brick Panel Set Standard Red 11) 502-097 Log Stand 12) 502-033 Front Air Box 13) 948-450 Burner Tube Front NG/...
Page 50 - VALVE TRAY ASSEMBLY
Regency ® P40-1 Direct Vent Gas Fireplace 50 P A R TS LIST PARTS LIST 120 122 121 125 127 128 129 126 VALVE TRAY ASSEMBLY Part # Description 120) 904-644 Ori fi ce # 35 121) 904-568 Ori fi ce # 44 122) 910-008 Pilot Assembly 125) 910-460 Valve NG - SIT 825 126) 910-937 Valve Solenoid - 3 Volt 127) 9...
Page 52 - NOTES
Regency ® P40-1 Direct Vent Gas Fireplace 52 NOTES ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ _________________________________________...
Page 55 - WARRANTY
Regency ® P40-1 Direct Vent Gas Fireplace 55 WARRANTY Regency ® Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility. FPI Fireplace Products International Ltd. i...
Page 56 - Installer: Please complete the following information; Printed in Canada; Register your Regency
Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: _________________________...