Page 2 - REGENCY; INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE; many features of your CLASSIC Direct Vent Freestanding Gas Stove.
2 Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater REGENCY Classic Direct Vent Freestanding Gas Stove This Regency Mobile/Manufactured Home listedappliance comes equipped with a dedicated #8ground lug to which an 8 gauge copper wire fromthe steel chassis ground must be attached. This Regenc...
Page 3 - TABLE OF CONTENTS; Venting Arrangements
Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater 3 TABLE OF CONTENTS Gas Connection ...................................................... 24High Elevation ......................................................... 24Gas Pressure Test .................................................. 24Valv...
Page 4 - SAFETY LABEL
4 Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater This is a copy of the label that accompanieseach CLASSIC Direct Vent Freestanding GasStove. We have printed a copy of the contentshere for your review. The safety label islocated on the back panel. NOTE: Regency units are constantly being i...
Page 5 - INSTALLATION
Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater 5 IMPORT ANT: SAVE THESE INSTRUCTIONS The CLASSIC Direct Vent Freestanding GasStove must be installed in accordance withthese instructions. Carefully read all the in-structions in this manual first. Consult thebuilding authority having jurisd...
Page 7 - OPTIONAL FAN INSTALLATION
Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater 7 Diagram 3 Caution: Ensure that the wires do nottouch any hot surfaces. Note: The #8 ground lug is a dedicatedground for mobile home use only. 9) Lift the fan assembly in through the pedestaland up through the cut out as shown indiagrams 3 a...
Page 8 - PEDESTAL ASSEMBLY; Fan Removal; LEG AND BOTTOM
8 Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater INSTALLATION PEDESTAL ASSEMBLY 1) For easier assembly, tip the stove on itsback (preferably onto a soft surface toprevent scratching). 2) Unscrew the 4 bolts in the underside of thestove. Align the holes in the corners of thepedestal top wi...
Page 10 - EXTERIOR VENT TERMINAL LOCATIONS
10 Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater INSTALLATION EXTERIOR VENT TERMINAL LOCATIONS *As specified in CGA B149 or ANZI 223.1 Installation Codes. Note: local Codes or Regulations may require different clearances. **A vent shall not terminate directly above a side-walk or paved d...
Page 11 - RIGID PIPE VENTING COMPONENTS LIST
Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater 11 946-506/P Vent Guard (Optional) 640-530/P Riser Vent Terminal 946-205 Vinyl Siding Shield for Riser Vent Terminal 946-208/P Vent Guard (Optional) - Riser Vent Terminal 946-523/P AstroCap Horizontal Cap 946-206 Vinyl Siding Standoff - Astro...
Page 12 - RIGID PIPE VENTING SYSTEMS; Horizontal or Vertical Terminations; Alternate
12 Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater RIGID PIPE VENTING SYSTEMS Horizontal or Vertical Terminations Alternate Horizontal Termination Caps INSTALLATION The FPI AstroCap TM and FPI Riser Vent terminal is certified for installations using FPI venting systems as well as Simpson D...
Page 13 - Venting Arrangements Examples:; Propane and Natural Gas: Residential, Manufactured
Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater 13 VENTING ARRANGEMENTS - VERTICAL TERMINATION SYSTEMS FOR RESIDENTIAL MAN- UFACTURED AND MOBILE HOMES The shaded area in the diagram below shows all allowablecombinations of straight vertical and offset to vertical runs withvertical terminat...
Page 14 - Option V; Option V
14 Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater Horizontal Venting with Two (2) 90 o Elbows Option V H + H1 A) 4' Min. 6' Max. B) 5' Min. 7' Max. C) 6' Min. 8' Max. Vertical Venting with Two (2) 90 o Elbows Option V H V + V1 A) 1' Min. 4' Max. 2' Min. B) 2' Min. 5' Max. 3' Min. C) 3' Mi...
Page 15 - DV ST OVE HORIZONTAL VENT KIT
Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater 15 INSTALLATION DV ST OVE HORIZONTAL VENT KIT (#946-116 & #946-216) INSTALLATION DV ST OVE HORIZONTAL VENT KIT DV 2 ft. Stove Vent Kit (Part # 946-116) and DV 4 ft. Stove Vent Kit (946-216) includeall the parts needed to install the C34 w...
Page 17 - TERMINATION KIT; Planning Your Dura-Vent; DURA-VENT VENTING COMPONENTS
Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater 17 INSTALLATION DURA-VENT TERMINATION KIT Planning Your Dura-Vent Installation There are two basic types of Dura-Vent DirectVent System installations: horizontal termina-tion and vertical termination. Confirm the max-imum horizontal run and m...
Page 18 - Alternate Horizontal
18 Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater You will require the following Dura-Vent vent-ing components with your new CLASSIC Di-rect Vent Freestanding Gas Stove. Pleasereview your product to make sure you haveeverything you need. In the event that you aremissing any part, contact ...
Page 19 - HORIZONTAL
Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater 19 INSTALLATION Diagram 4 Below Grade Installation If the Snorkel Termination must be installedbelow grade, i.e. basement application, prop-er drainage must be provided to preventwater from entering the Snorkel Termination.Refer to Diagram 4....
Page 20 - VERTICAL
20 Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater Diagram 9 p e n e t r a t e t h eroof. Determine ifc e i l i n g j o i s t s ,roof rafters orother framing willo b s t r u c t t h eventing system.You may wishto relocate theappliance or too f f s e t , a sshown in dia-gram 9 to avoidc u t...
Page 21 - CATHEDRAL CEILINGS; Offset Chart; Slope
Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater 21 INSTALLATION CATHEDRAL CEILINGS Round Support (RDS) & Square Support (SQS) If your home has a cathedral ceiling (no atticspace between the ceiling and the roof), installthe chimney and support as follows. 1) Situate the chimney in a co...
Page 22 - Support extensions - Round; CONVERTING A; General
22 Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater Support extensions - Round (RDSE) or square (SQSE) Steep pitched cathedral ceilings may requirethe use of a support extension. This piece fitsdown inside the support and can be adjustedto increase the support's length by up to 22".The ...
Page 23 - Converting a Masonry Chimney
Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater 23 INSTALLATION 7) The connection between the appliance and the Retro Connector may be completed withsections of black direct vent pipe, togetherwith an adjustable length. Converting a Masonry Chimney Important: The existing masonry flueopeni...
Page 24 - SYSTEM DATA; GAS CONNECTION; Valve Description; HIGH ELEVATION
24 Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater SYSTEM DATA (For 0 to 4,500 feet altitude) Orifice Sizes: Burner Natural Gas #36 Burner Propane #52 Max. Input Rating Natural Gas 32,000 Btu/h Propane 32,000 Btu/h Min. Input Rating Natural Gas 16,000 Btu/h Propane 16,000 Btu/h Supply Pres...
Page 25 - DOOR AND GLASS; LOG INSTALLATION; DO NOT TRY TO TURN DOOR
Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater 25 INSTALLATION Diagram 1 Diagram 5 Diagram 2 (Use Extreme Caution and ensure properlight off of burner.) Note: If the flame hesitates at any point, check the area of hesitation ands e e i f t h e r e i s a n e m b e r o r r o c k -wool block...
Page 26 - DO NOT TRY TO TURN
26 Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater CAUTION Any alteration to the product that caus-es sooting or carboning that resultsin damage to the unit is not the re-sponsibility of the manufacturer andwill not be covered by the warranty. OPTION 1: REMOTE CONTROL INSTALLATION Use the ...
Page 27 - WIRING DIAGRAM
Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater 27 WIRING DIAGRAM INSTALLATION This heater does not require a 120V A.C. supplyfor operation. In case of a power failure, theburner switch and the optional remote control/thermostat will continue to operate. However, a 120V A.C. power supply i...
Page 28 - OPERATING INSTRUCTIONS
28 Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS 1) Read and understand these instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock. 3) Check to ensure there are no gas...
Page 29 - COPY OF THE LIGHTING PLATE INSTRUCTIONS; AERATION ADJUSTMENT
Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater 29 COPY OF THE LIGHTING PLATE INSTRUCTIONS OPERATING INSTRUCTIONS AERATION ADJUSTMENT Natural Gas -5/16" (7.9 mm)Propane - 5/8" (15.9mm) This adjustment is performed by the installerand is primarily used in installations at highelevat...
Page 30 - MAINTENANCE
30 Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater MAINTENANCE GENERAL VENT MAINTENANCE Conduct an inspection of the venting systemsemiannually. Recommended areas to inspectare: 1) Check areas of the Venting System whichare exposed to the elements, for corrosion.These will appear as rust s...
Page 32 - PARTS LIST; MAIN ASSEMBLY
32 Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater PARTS LIST MAIN ASSEMBLY Part # Description 1) 490-550 Door Assembly-Gold (no glass) 490-552 Door Assembly-Black (no glass) 3) 846-302 Small Glass 4) 936-240 Glass Gasket (1/8") 5) * Nut - 3/8 N/C Jam 6) 490-028 Glass Frame 7) 948-074/...
Page 33 - BURNER ASSEMBLY & LOG SET
Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater 33 PARTS LIST BURNER ASSEMBLY & LOG SET Part # Description 52) 910-190 Piezo Ignitor & Nut 53) * Control Panel 54) * Control Panel Decal 492-562/P Valve Assembly - S.I.T. - Nat. Gas492-563/P Valve Assembly - S.I.T. - Propane 63) 910-3...
Page 34 - BASE OPTIONS
34 Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater BASE OPTIONS Part # Description Part # Description 490-921 Complete Floor Shield 100) 948-216 Regency Logo 102) 904-257 Magnetic Catch (Large) 103) * 11" Pedestal Hinge 108) 910-246 Burner ON/OFF Switch 109) 910-140 Fan HIGH/OFF/LOW Sw...
Page 35 - WARRANTY
Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater 35 WARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects eachunit thoroughly before it leaves our facility. FPI Fireplace Products Interna...
Page 36 - Installer: Please complete the following information; Printed in Canada
Installer: Please complete the following information Dealer Name & Address: ________________________________________________ ______________________________________________________________________ Installer: ______________________________________________________________ Phone #: _________________...