PVI Industries 54 N 125A-MXG - Manual

PVI Industries 54 N 125A-MXG

PVI Industries 54 N 125A-MXG – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
Page: / 1
Loading the manual
Page 1

Product is patented in the U.S., Canada, and Mexico.

PVI INDUSTRIES, LLC

FORT WORTH, TEXAS 76111

PV 6139 08/07

(800) 784-8326

•

www.pvi.com

MAXIM • PACKAGED GAS WATER HEATER

NICKELSHIELD

®

NICKEL-PLATED STORAGE TANK

125 GALLON TANK SERIES

MODEL NUMBER

20 N 125A-MXS

27 N 125A-MXS

40 N 125A-MXS

54 N 125A-MXG 72 N 125A-MXG

80 N 125A-MXG

GPH Recovery at 40° to 120° F

245

330

490

670

900

1000

GPH Recovery at 40° to 140° F

195

260

390

540

720

800

Input

Btu/h

199,000 270,000 399,000 540,000 720,000 800,000

*

Min. inlet flow gas pressure " W.C.

5.5

5.5

5.5

4.5

4.5

4.5

*

Max static gas pressure “W.C.

9

9

9

14

14

14

A Cold Inlet - NPT

2

2

2

2

2

2

B Hot Outlet - NPT

2

2

2

2

2

2

C

Drain

-

NPT

1 1 1 1 1 1

D I - Beam Skids

3 x 34-1/2

3 x 34-1/2

3 x 34-1/2

3 x 34-1/2

3 x 34-1/2

3 x 34-1/2

E

Overall

Depth

45 45 45 53 52 54

F

Overall

Height

75 75 75 82 82 82

G Flue Outlet Diameter

5

6

7

8

10

10

H Gas Inlet - NPT

1/2

3/4

3/4

1

1-1/4

1-1/4

J Motor HP 120 V, 1Ø, 60 Hz.

1/6

1/6

1/6

1/3

1/3

1/3

K Motor

Amps

1.75

1.75

1.75

8

8

8

L

Height

to

Outlet

65 65 65 73 73 73

M

Height

to

Inlet

28 28 28 36 36 36

Approx. Shipping Weight - lbs

1020

1070

1130

1260

1370

1390

ASHRAE 90.1 compliant.
Models with suffix “MXS” are registered as low NOx water heaters in California and Texas
* The information presented is for natural gas 0.6 S.G. – For operation with propane (LP gas), consult the factory.
* For gas pressures outside of this range, consult factory.
Dimensions are in inches unless otherwise specified.
For standard and optional equipment, see form # PV 6137.


STANDARD ELECTRICAL CONNECTIONS

VENTING REQUIREMENTS

CONTROL VOLTAGE: 120V, 1Ø, 60 Hz, 2 amps

SEE ABOVE CHART FOR BLOWER MOTOR AMPS

-.02

"

TO -.06

"

W.C. (negative pressure)

TYPE B VENTING

THE ENTIRE VENT SYSTEM SHOULD NEVER BE SIZED BASED

UPON THE

VENT CONNECTION DIAMETER EXCLUSIVELY.

FOR PROPER VENT SIZING, CONSULT THE NATIONAL FUEL

GAS CODE UNDER “FAN-ASSISTED”



PVI RESERVES THE RIGHT TO CHANGE THE DESIGN AND
SPECIFICATION WITHOUT NOTICE.

1. Control Enclosure
2. ASME Temperature &
Pressure Relief Valve
3. 3” NPT Handhole

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Was this manual helpful?

About this manual

Brand
PVI Industries
Model
54 N 125A-MXG
Document type
Manual
Language(s)
English
Pages
1
File size
37.2 KB
Format
PDF

Ask a question