Pioneer RYB009GMFILDAD-16 - User Manual

Pioneer RYB009GMFILDAD-16

Pioneer RYB009GMFILDAD-16 Air Conditioner – User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
61 Page 61
62 Page 62
63 Page 63
64 Page 64
65 Page 65
66 Page 66
67 Page 67
68 Page 68
69 Page 69
70 Page 70
71 Page 71
72 Page 72
73 Page 73
74 Page 74
75 Page 75
76 Page 76
77 Page 77
78 Page 78
79 Page 79
80 Page 80
81 Page 81
82 Page 82
83 Page 83
84 Page 84
85 Page 85
86 Page 86
87 Page 87
88 Page 88
89 Page 89
90 Page 90
91 Page 91
92 Page 92
93 Page 93
94 Page 94
95 Page 95
96 Page 96
97 Page 97
98 Page 98
99 Page 99
100 Page 100
101 Page 101
102 Page 102
103 Page 103
104 Page 104
105 Page 105
106 Page 106
107 Page 107
108 Page 108
109 Page 109
110 Page 110
111 Page 111
112 Page 112
113 Page 113
114 Page 114
115 Page 115
116 Page 116
117 Page 117
118 Page 118
119 Page 119
120 Page 120
121 Page 121
122 Page 122
123 Page 123
124 Page 124
125 Page 125
126 Page 126
127 Page 127
128 Page 128
129 Page 129
130 Page 130
131 Page 131
132 Page 132
133 Page 133
134 Page 134
135 Page 135
136 Page 136
137 Page 137
138 Page 138
139 Page 139
140 Page 140
141 Page 141
142 Page 142
143 Page 143
144 Page 144
145 Page 145
Page: / 145

Table of Contents:

  • Page 2 – CONTENTS
  • Page 7 – Part Names and Features; Series
  • Page 8 – Ceiling Cassette Unit
  • Page 9 – Ducted Concealed Units
  • Page 10 – Floor Console Units
  • Page 13 – Central control ports
  • Page 14 – mm up; Built-in display board; with float switch
  • Page 15 – Cold; Old
  • Page 16 – The drain pump can lift the condensing water up to 750mm upmost.
  • Page 17 – Quick Cooling To maintain room temp
  • Page 18 – Heating mode; DC indoor fan motor, which has five speeds.
  • Page 20 – Optional drainage pipe connection; C Panel (LED display) D Panel; Convenience operating and easy maintenance; Remote controller as standard, wired controller for optional.; Easy installation, save working time; The wiring works can be finished before installation.; Outside water pump for optional when ceiling installation.
  • Page 21 – Duct Units
  • Page 23 – Cassette Units
  • Page 24 – Console Units; Hanging arm
  • Page 26 – Model
  • Page 27 – Ensure enough space required for installation and maintenance.
  • Page 28 – Console Unit
  • Page 30 – Refrigerant Cycle Diagram; INDOOR
  • Page 42 – Outdoor Controller Set of; For
  • Page 45 – RB012GMFILCFHD; Code 0 Code 1
  • Page 50 – Electric Characteristics
  • Page 51 – Sound Level; Suction; Concealed Duct Type
  • Page 54 – Outdoor Unit
  • Page 55 – 0 Accessories
  • Page 57 – 1 The Specification of Power
  • Page 58 – 2 Field Wiring
  • Page 59 – 2 Installation Details; Location selection; Indoor unit installation
  • Page 61 – Cassette indoor unit installation
  • Page 62 – Note: The panel shall be installed after the
  • Page 63 – Service space for indoor unit; Capacity
  • Page 64 – Install the main body; Outdoor unit installation
  • Page 65 – Refrigerant pipe installation; Maximum pipe length and height
  • Page 66 – Air purging with vacuum pump
  • Page 67 – Air purging by refrigerant
  • Page 69 – Drainage pipe installation; measures
  • Page 71 – Water storage pipe setting; Blowhole setting
  • Page 73 – Additional refrigerant charge
  • Page 74 – Engineering of insulation; Insulation of refrigerant pipe
  • Page 75 – Engineering of electrical wiring
  • Page 77 – Operation Characteristics; come into operation and cause the unit to operate abnormally.
  • Page 78 – Electronic Function; T2B: Coil temperature of indoor heat exchanger; Display function; minute delay for the 1; time stand-up and 3
  • Page 79 – Condenser high temperature T3; the; Operation Modes and Functions
  • Page 80 – Auto fan in cooling mode acts as follow:; Auto fan action in heating mode:; Condition of ending defrosting:
  • Page 81 – Evaporator; Decrease: Decrease the running frequency to
  • Page 83 – Point check function
  • Page 86 – Indoor Unit Error Display
  • Page 89 – Outdoor check function
  • Page 91 – Diagnosis and Solution; Error Code; Indoor PCB
  • Page 97 – EC; Check leakage of system; Power off, then restart the; check blockIng of system and
  • Page 98 – Water-level alarm malfunction; diagnosis and solution; EE; Wiring mistake
  • Page 105 – Main parts check; Temperature sensor checking; Temperature Sensors.
  • Page 106 – Appendix; K Ohm
  • Page 107 – ppendix 2; Temperature Sensor Resistance Value Table for T5 (
  • Page 109 – Compressor checking; Measure the resistance value of each winding by using the tester.
  • Page 110 – IPM continuity check; tester to measure the resistance between P and UVWN UVW and N.; : Pressure on Service Port
  • Page 112 – Disassembly Instructions
  • Page 114 – sensor
  • Page 116 – screws
  • Page 123 – name; Open the front panel
  • Page 124 – Repeat the operation of step1~ step6 of No2.
  • Page 135 – screws of front panel
  • Page 139 – electronic control box.
  • Page 141 – screws of top panel
  • Page 144 – new
Loading the manual

LIGHT COMMERCIAL SPLIT SYSTEMS

3D DC INVERTER HEAT PUMP

SERVICE MANUAL

Single Zone





ALL RIGHTS RESERVED. PARKER DAVIS HVAC INTERNATIONAL, INC., DORAL, FL 33172 USA

Phone: (800) 243-0340 www.highseer.com



Revision A: 1605, Content updated. 

Model Numbers: 
Indoor Unit Model Numbers: 

Ceiling Cassette 

 

Concealed Ducted   

Floor, Ceiling, Low Wall 

CB009GMFILCFHD   

RB009GMFILCFHD

   

FB009GMFILCFHD 

CB012GMFILCFHD   

RB012GMFILCFHD

   

FB012GMFILCFHD 

CB018GMFILCFHD   

RB018GMFILCFHD

   

UB018GMFILCFHD 

CB024GMFILCFHD   

RB024GMFILCFHD

   

UB024GMFILCFHD 

CB036GMFILCFHD   

RB036GMFILCFHD

   

UB036GMFILCFHD 

CB048GMFILCFHD   

RB048GMFILCFHD

   

UB048GMFILCFHD 

 
Outdoor Unit: 

Standard Communication Circuit Models: 

YN009GMFI22RPD   

YN012GMFI22RPD   

YN018GMFI22RPD 

YN024GMFI22RPD   

 

RS‐485 Communication Circuit Models: 

YN036GMFI17RUD   

YN038GMFI17RUD   

 

Table of Contents
1. Precaution
2. Part Names And Functions
3. Dimension
4. Service space
5. Refrigerant Cycle Diagram
6. Wiring Diagram
7. Static Pressure
8. Electric Characteristics
9. Sound Level
10. Accessories
11. The Specification of Power
12. Installation Details
13. Operation Characteristics
14. Electronic Function
15. Solar Panel
16. Troubleshooting
17. Disassembly Instructions

WARNING

Installation MUST conform with local building codes or, in the absence of local codes, with the National

Electrical Code NFPA70/ANSI C1-1993 or current edition and Canadian Electrical Code Part1 CSA

C.22.1.

The information contained in the manual is intended for use by a qualified service technician familiar

with safety procedures and equipped with the proper tools and test instruments

Installation or repairs made by unqualified persons can result in hazards to you and others.

Failure to carefully read and follow all instructions in this manual can result in equipment malfunction,

property damage, personal injury and/or death.

This service is only for service engineer to use.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - CONTENTS

CONTENTS 1. Precaution .................................................................................................................................................. 1   1.1 Safety Precaution ...........................................................................................................

Page 7 - Part Names and Features; Series

4 2. Part Names and Features 2.1 Model Names of Indoor/Outdoor units Series Capacity Indoor units Outdoor units Cassette 9K CB009GMFILCFHD YN009GMFI22RPD Duct RB009GMFILCFHD Console FB009GMFILCFHD Cassette 12K CB012GMFILCFHD YN012GMFI22RPD Duct RB012GMFILCFHD Console FB012GMFILCFHD Cassette 18K CB01...

Page 8 - Ceiling Cassette Unit

5 2.2 Part names of Indoor/Outdoor units Ceiling Cassette Unit

Other Pioneer Air Conditioners Models

All Pioneer Air Conditioners