Pioneer DYR4260GMFI18R - User Manual

Pioneer DYR4260GMFI18R

Pioneer DYR4260GMFI18R Air Conditioner – User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
61 Page 61
62 Page 62
63 Page 63
64 Page 64
65 Page 65
66 Page 66
67 Page 67
68 Page 68
69 Page 69
70 Page 70
71 Page 71
72 Page 72
73 Page 73
74 Page 74
75 Page 75
Page: / 75

Table of Contents:

  • Page 2 – SAFETY SUMMARY; IMPORTANT NOTICE; Use refrigerant R410A in the refrigerant cycle.
  • Page 3 – CHECKING PRODUCT RECEIVED
  • Page 4 – Table of Contents
  • Page 5 – GENERAL
  • Page 6 – Unit installation; Power Supply; Operating temperature range; Mode
  • Page 10 – OUTLINES AND DIMENSIONS
  • Page 12 – ELECTRICAL DATA
  • Page 13 – operating ambient temperature of outdoor unit.
  • Page 14 – CAPACITIES AND SELECTION DATA; Airflow
  • Page 15 – K indoor unit
  • Page 16 – Performance data (Cooling operation at rated frequency)
  • Page 23 – Heat
  • Page 26 – Indoor unit; difference; Cooling; Heating; Model
  • Page 27 – Correction factors according to defrosting operation
  • Page 29 – REFRIGERANT CYCLE; List of components
  • Page 31 – WIRING DIAGRAM; DIP Switch Setting of Outdoor Unit
  • Page 32 – Electric wiring diagram 215
  • Page 33 – Control board picture; Description; Main control board
  • Page 34 – board
  • Page 36 – Drive board
  • Page 37 – Filter
  • Page 38 – Recommended Wire Size
  • Page 39 – FIELD SETTING; Forced; Pump down; Outdoor unit model; Cooling only set
  • Page 40 – enter refrigerant recovery mode and will run normally.
  • Page 41 – -segment display Introduction; Running parameter query; Query by 7 segment display; Select; There are 3 buttons on the digital display board
  • Page 42 – Parameters can be checked in the following table below.
  • Page 44 – PIPING WORK AND REFRIGERANT CHARGE; Additional refrigerant charge; and straight as possible.
  • Page 45 – Air tight procedure; .4 Additional refrigerant charge; er
  • Page 46 – INSTALLATION TOOLS AND INSTALLATION FLOW CHART; Necessary Tools and Instrument List for Installation
  • Page 48 – Control function
  • Page 49 – SENSOR PARAMETER
  • Page 52 – THE PARAMETER OF THE OTHER SENSOR
  • Page 55 – Troubleshooting for normal malfunction
  • Page 56 – TROUBLESHOOTING; Fault code displayed by LED lamps on outdoor main control board.
  • Page 57 – Fault code will be displayed directly on 7 segment display board.; LED1:Drive failure indicator; Drive fault code display
  • Page 58 – The following is the fault code table of outdoor units.; Table; s for
  • Page 59 – for
  • Page 61 – : Overload in cooling mode
  • Page 63 – Fault
  • Page 65 – CHECKING COMPONENTS
  • Page 66 – Check parts unit; Outdoor unit fan motor; Compressor examination and repairing
  • Page 67 – NOTE; Don’t put a compressor on its side or turn over.
  • Page 68 – The special tools for compressor & motor disassembly and assembly; Tool; Step
  • Page 69 – DISASSEMBLY AND ASSEMBLY FOR COMPRESSOR AND MOTOR
  • Page 71 – An illustration to outdoor unit signal
  • Page 72 – CONTORL LOGIC DESCRIPTION
  • Page 73 – with the decreased target pressure, it is taken; Evaporator Low-temperature Protection; Cooling mode: When the saturation temperature
  • Page 74 – which is got from high pressure cycling) T3
  • Page 75 – is a registered trademark of Parker Davis HVAC International, Inc.; Tel; Scan the below code to visit our support page
Loading the manual

CENTRAL SPLIT AIR CONDITIONER

Technical &

Service Manual

v1.0

IMPORTANT NOTICE:

Thank you very much for purchasing this Air Conditioner. Please read this manual carefully before

installing or operating your new air conditioning system. Be sure to save this manual for future reference.

HIGH EFFICENCY

CONDENSING UNIT

Models:
• YH1824GHFD18R2
• YH3036GHFD18R2
• YH4248GHFD18R2
• YH4860GHFD18R2

- R-410A REFRIGERANT
- 208~230 V, 1 Phase, 60 Hz
- 18 SEER

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - SAFETY SUMMARY; IMPORTANT NOTICE; Use refrigerant R410A in the refrigerant cycle.

SAFETY SUMMARY IMPORTANT NOTICE ● We pursue a policy of continuing improvement in design and performance of products. The right istherefore reserved to vary specifications without notice. ● We cannot anticipate every possible circumstance that might involve a potential hazard. ● This air conditioner...

Page 3 - CHECKING PRODUCT RECEIVED

● If circuit breaker or fuse is often activated, stop the system and contact your service contractor. ● Check that the ground wire is securely connected. If the unit is not correctly grounded, it will lead to electric shock. Do not connect the ground wiring to gas piping, water piping, lightningcond...

Page 4 - Table of Contents

1. General ..................................................................................................................................................1 1.1 Features ...................................................................................................................................

Other Pioneer Air Conditioners Models

All Pioneer Air Conditioners