2 Contents Before using the unit Introduction .................................................................................. 3Important Safety Information ...................................................... 41. Overview ............................................................................
Page 3 - Introduction; The unit also stores up to 14 measurements in memory.
3 EN Introduction Thank you for purchasing the OMRON M1 Compact Upper Arm Blood Pressure Monitor. The OMRON M1 Compact is a manual inflation blood pressure monitor, operating on the oscillometric principle. It measures your blood pressure and pulse rate simply and quickly. The unit also stores up to...
Page 4 - Important Safety Information
4 Important Safety Information Consult your doctor during pregnancy, arrhythmia and arteriosclerosis.You should never change the dosage of medication prescribed by your doctor. Please read this section carefully before using the unit. Warning: • Indicates a potentially hazardous situation which, if ...
Page 5 - General Precautions
5 Important Safety Information EN • Do not inflate the arm cuff over 299 mmHg. If the cuff is over inflated, it can cause internal bleeding. • Do not use a mobile phone near the unit. This could cause a malfunction. (Battery Usage) • If battery fluid should get on your skin or clothing, immediately ...
Page 6 - inflation bulb
6 1.Overview 1. Overview Main unit Arm Cuff A. DisplayB. I/O button (Power switch)C. Air connector for cuff and inflation bulb D. M (Memory) button E. Battery compartment F. Arm cuff (Medium cuff: arm circumference 22-32 cm) G. Air Tube B A C D E G F HEM-4022-IM_Main_[D].book 6 ページ 2011年11月2日 水曜日 午後...
Page 7 - Air Tube
7 1.Overview EN Inflation Bulb Display H. Air Release ButtonI. Air Tube J. Air Inflation Bulb K. Systolic blood pressureL. Diastolic blood pressureM. Memory symbol Displayed when viewing values stored in memory N. Battery low symbol O. Heartbeat symbol 1. Flashes during measurement 2. If flashing af...
Page 8 - batteries
8 1.Overview Package contents (others) T. Storage caseU. Four “AAA” alkaline (LR03) batteries • Instruction manual• Guarantee card• Blood pressure pass U T HEM-4022-IM_Main_[D].book 8 ページ 2011年11月2日 水曜日 午後3時24分
Page 9 - Installing/Replacing the Batteries; Turn the main unit upside down.
9 2.Preparation EN 2. Preparation 2.1 Installing/Replacing the Batteries 1. Turn the main unit upside down. 2. Slide the battery cover in the direction of the arrow while pressing the ribbed part of the cover. 3. Install or replace four “AAA” size batteries so that the + (positive) and - (negative) ...
Page 10 - Battery Life & Replacement
10 2.Preparation Battery Life & Replacement If the battery low symbol ( ) appears on the display, replace all four batteries at the same time. - When the battery low symbol ( ) starts to blink, you will still be able to use the unit for a short while. You should replace the batteries with new on...
Page 11 - How to Sit Correctly When Taking a Measurement; • Measurements should be taken in a quiet place and you should be in; Correct; Operating instructions
11 3.Using the Unit EN 3. Using the Unit 3.1 How to Sit Correctly When Taking a Measurement Correct posture during measurement is necessary to get accurate results. Notes: • Measurements should be taken in a quiet place and you should be in a relaxed, seated position. Make sure that the room is not ...
Page 12 - Incorrect Posture; so that you tend to lean forward
12 3.Using the Unit Note: You can take a measurement on either your left or right arm. The blood pressure can differ between the right arm and the left arm and therefore also the measured blood pressure values can be different. Omron recommends to always use the same arm for measurement. If the valu...
Page 13 - Applying the Arm Cuff
13 3.Using the Unit EN 3.2 Applying the Arm Cuff Be sure to wrap the arm cuff correctly so that you get accurate results. Measurements can be taken in light clothing. However, please remove thick clothes, such as sweaters, before taking a reading. 1. Connect the air tube of the arm cuff and the infl...
Page 14 - Taking measurements on the right arm
14 3.Using the Unit 3. Position the arm correctly. Taking measurements on the right arm Apply the cuff so that the air tube is at the side of your elbow.• Be careful not to rest your arm on the air tube, or otherwise restrict the flow of air to the cuff. • The cuff should be 1 to 2 cm above the elbo...
Page 15 - Taking a Reading
15 3.Using the Unit EN 3.3 Taking a Reading 1. Preparation1) Press the air release button to release any air in the arm cuff. 2) Press the I/O button to turn the unit on.3) All items in the display will be displayed briefly.4) The deflation symbol will flash.5) Finally, the heartbeat symbol will app...
Page 17 - Diastolic blood; Common Causes of Inaccurate Results
17 3.Using the Unit EN 5. Check the measurement results.The unit automatically stores blood pressure and pulse rate into its memory, Refer to “3.4 Using the Memory Function”. Note: Wait 2-3 minutes before taking another blood pressure measurement. Waiting between readings allows the arteries to retu...
Page 19 - What is Irregular Heartbeat?; on the symbol when the measurement results are displayed.; If the irregular heartbeat symbol (; Normal Heartbeat
19 3.Using the Unit EN What is Irregular Heartbeat? An irregular heartbeat is a heartbeat rhythm that varies by more than 25% from the average heartbeat rhythm detected while the unit is measuring the systolic and diastolic blood pressure.If such an irregular rhythm is detected more than twice durin...
Page 20 - Using the Memory Function
20 3.Using the Unit 3.4 Using the Memory Function The unit automatically stores up to 14 sets of measurement values (blood pressure and pulse rate). When 14 sets of measurement values are stored, the oldest record is deleted to save the most recent values. 1. Press the I/O button to turn the power o...
Page 23 - Quick Reference Guide
23 4.Quick Reference Guide EN 4. Quick Reference Guide Use this as a quick reference guide only. If you are using this device for the first time, please read carefully Chapter 3 of this Instruction Manual.To help ensure a reliable reading, avoid eating, drinking alcohol, smoking, or exercising for a...
Page 24 - Handling Errors and Problems; Care and maintenance
24 5.Handling Errors and Problems 5. Handling Errors and Problems 5.1 Error Messages Error Display Cause Remedy Cuff is under inflated. Press air release button and restart the measurement with a higher inflation level. Carefully read steps under section 3.3. Movement during measurement Repeat measu...
Page 25 - The irregular heartbeat symbol (; Error Display
25 5.Handling Errors and Problems EN Note: The irregular heartbeat symbol ( ) may also be displayed with error messages. Device error. Contact your OMRON retail outlet or distributor.Refer to Chapter 8. Pressure is too low. Press the inflation bulb to inflate the arm cuff until the reinflation symbo...
Page 26 - Troubleshooting; Problem
26 5.Handling Errors and Problems 5.2 Troubleshooting Problem Cause Remedy The reading is extremely low (or high). Arm cuff not applied correctly. Apply the arm cuff correctly. Refer to section 3.2. Movement or talking during measurement. Remain still and do not talk during measurement.Refer to sect...
Page 28 - Maintenance and Storage; Maintenance; • Do not carry out repairs of any kind yourself. If a defect occurs,; Calibration and Service; and is designed for a long service life.
28 6.Maintenance and Storage 6. Maintenance and Storage Maintenance To protect your unit from damage, please observe the following:• Do not subject the main unit, cuff and inflation bulb to extreme temperatures, humidity, moisture or direct sunlight. • Do not fold the cuff or tubing tightly.• Do not...
Page 29 - Storage; Keep the unit in its storage case when not in use.
29 6.Maintenance and Storage EN Storage Keep the unit in its storage case when not in use. 1. Unplug the air tube from the air connector. 2. Gently fold the air tube into the arm cuff. Note: Do not bend the air tube excessively. 3. Place the arm cuff, inflation bulb and main unit in the storage case...
Page 30 - Medium Arm Cuff; Large Arm Cuff; Small Arm Cuff; Small cuff and bulb combination; Regular bulb
30 7.Optional Parts 7. Optional Parts Note: You need a special bulb for a small cuff. When you use a small cuff, please replace a cuff and a bulb together. Medium Arm Cuff Arm circumference 22 - 32 cm Large Arm Cuff Arm circumference 32 - 42 cm Small Arm Cuff Arm circumference 17 - 22 cm Small cuff ...
Page 31 - Caution: Please read the instruction manual carefully before
31 8.Technical Data EN 8. Technical Data Note: Subject to technical modification without prior notice • This OMRON product is produced under the strict quality system of OMRON Healthcare Co. Ltd., Japan. The Core component for OMRON blood pressure monitors, which is the Pressure Sensor, is produced ...
Page 33 - Some Useful Information about Blood Pressure; What is Blood Pressure?
33 9.Some Useful Information about Blood Pressure EN 9. Some Useful Information about Blood Pressure What is Blood Pressure? Blood pressure is a measure of the force of blood flowing against the walls of the arteries. Arterial blood pressure is constantly changing during the course of the heart’s cy...
Page 35 - Manufacturer
35 9.Some Useful Information about Blood Pressure EN Manufacturer OMRON HEALTHCARE Co., Ltd. 53, Kunotsubo, Terado-cho, Muko, Kyoto, 617-0002 JAPAN EU-representative OMRON HEALTHCARE EUROPE B.V. Scorpius 33, 2132 LR Hoofddorp, THE NETHERLANDSwww.omron-healthcare.com Production facility OMRON (DALIAN...