Omega OS530HRE - Manual

Omega OS530HRE

Omega OS530HRE – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
61 Page 61
62 Page 62
63 Page 63
64 Page 64
65 Page 65
66 Page 66
67 Page 67
68 Page 68
69 Page 69
70 Page 70
71 Page 71
72 Page 72
73 Page 73
74 Page 74
75 Page 75
76 Page 76
77 Page 77
78 Page 78
79 Page 79
80 Page 80
81 Page 81
82 Page 82
83 Page 83
84 Page 84
Page: / 84

Table of Contents:

  • Page 2 – OMEGAnet
  • Page 3 – Unpacking Instructions; Notes
  • Page 4 – Accessories; . We can also be reached on the; Description; Hard Carrying Case, Standard; NOTE
  • Page 6 – Handheld Infrared Thermometer
  • Page 8 – General Description
  • Page 9 – be set and remain in memory until reset.; Table 1-1. OS530 Series Handheld Infrared Thermometer Features; Features
  • Page 12 – Parts of the Thermometer; Refer to Chapter 3 for Laser Sight information.
  • Page 13 – Key; OMEGASCOPE
  • Page 14 – Figure 1-3. OS530E/OS520E Series Handheld Infrared Thermometer
  • Page 16 – If the
  • Page 17 – Using the Handheld Infrared Thermometer; Operating the Thermometer
  • Page 18 – *SPOT DIAMETER MEASURED
  • Page 21 – • Spot Measurement —; Measures the temperature of discrete objects; • Differential Measurement —; Measures the temperature differential
  • Page 22 – • Static Surface Scan; – Measures the temperature across a static; • Moving Surface Scan; - Measures the Temperature of Points on a; • Fixed Point Monitoring Over Time; - Monitors the temperature at
  • Page 23 – Pull the trigger and press the; Figure 2-12. General Operational Block Diagram
  • Page 24 – Press; LCK; Real T
  • Page 25 – hile in these 7 modes:
  • Page 26 – Refer to Appendices B and C for information on emissivity.; To unlock the trigger function, while in Emissivity and
  • Page 27 – Model HH-DM Distance Meter; Distance
  • Page 28 – key will convert the distance
  • Page 29 – Figure 2-18. Line of Sight of the Infrared Thermometer
  • Page 30 – key will; key to reset or turn off the; period as stated in the specifications.
  • Page 31 – key to; Turning on the Display Backlighting; key
  • Page 32 – • To set the high alarm value:; If you are not in High Alarm Display Mode (HAL) when
  • Page 33 – If the temperature drops below the low alarm; key to disable the low alarm.
  • Page 34 – Compensation; To disable this mode, press the
  • Page 35 – To disable the Ambient Target Temperature; Software Installation:; Run... from the start
  • Page 36 – Sending temperature data to PC in Real Time:
  • Page 37 – Download Stored Temperature data to PC
  • Page 38 – Menu Description
  • Page 40 – Command
  • Page 41 – String
  • Page 42 – 4 Storing Temperature Data on Command
  • Page 43 – 5 Logging Temperature Data in Real Time
  • Page 44 – 6 Erasing the Temperature Data from Memory
  • Page 45 – Figure 2-19. General Operational Block Diagram; In order to get into the Recall Mode of operation,; Start; Pull Tri; Real Time; o keys; Display Turns Off in; Display T
  • Page 46 – Recall Modes
  • Page 47 – The thermometer stores the last temperature measured in; Calculated values; Reviewing Previously Stored Temperature Data
  • Page 48 – Refer to the inside back cover for product warning label.; CAUTION
  • Page 49 – Laser Sighting; of the Thermometer
  • Page 50 – Operating the Laser Sighting; Set the laser power switch to the ON position as shown in; Laser Sighting Status; Laser Dot
  • Page 51 – Figure 3-4 Lines of Sight of the Laser Sighting and Thermometer
  • Page 53 – Figure 4-1. Installing the Sighting Scope
  • Page 54 – Rotate the wheel
  • Page 55 – Digital Video Camera
  • Page 56 – Invert the thermometer and open the cover of the battery; The icon; Safety Warning
  • Page 57 – Maintenance; Cleaning the Lens
  • Page 58 – Troubleshooting Guide; THERMOMETER; Problem; The thermometer does 1a. Properly install fresh batteries.
  • Page 60 – The thermometer has to stabilize
  • Page 62 – Specifications; (Specifications are for all models except where noted)
  • Page 65 – LASER SIGHTING
  • Page 66 – DIGITAL VIDEO CAMERA
  • Page 68 – Glossary of Key Strokes
  • Page 70 – Appendix: How Infrared Thermometry Works; Thermal Radiation; Figure A-1. Infrared Thermometer Block Diagram; OR
  • Page 71 – Blackbody; gray; Spectral Distribution; Figure A-2. Blackbody Spectral Distribution
  • Page 72 – where; Calculating Temperature; x K
  • Page 73 – Optics Field of View; Figure A-3. Field of View of a Thermometer; = 10 gives you approximately a 1 foot spot size at a
  • Page 74 – Appendix: Emissivity Values; guidelines for estimating the emissivity; MET; Material
  • Page 75 – NONMET
  • Page 76 – Aim the thermometer at the object.; Method 2
  • Page 77 – Appendix: Determining an Unknown Emissivity; Method 3; Target
  • Page 78 – Appendix - Determining an Unknown Emissivity; Method 4; Figure C-2. Determining Emissivity with a Drilled Hole; Adjust the emissivity of the thermometer until the temperature
  • Page 79 – Appendix: Determining an Unknown Emissivity
  • Page 80 – Index
  • Page 81 – Fixed Point Monitoring over
  • Page 82 – Real Time Mode Block
  • Page 83 – RETURN REQUESTS / INQUIRIES; Warning and Certification Label
  • Page 84 – Shop online at omega.com
Loading the manual

OS530LE, OS532E, OS53xE-CF,

OS533E, OS534E, OS530HRE,

OS523E, OS524E OMEGASCOPE

®

Handheld Infrared Thermometer

Shown with
Built-in Distance
Measuring Option
and Digital Video
Camera Attachment

TM

omega.com

e-mail: [email protected]

For latest product manuals:

omegamanual.info

User’s Guide

Shop online at

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - OMEGAnet

Servicing North America: U.S.A.: One Omega Drive, Box 4047 ISO 9001 Certified Stamford, CT 06907-0047Tel: (203) 359-1660FAX: (203) 359-7700e-mail: [email protected] Canada: 976 BergarLaval (Quebec) H7L 5A1, CanadaTel: (514) 856-6928FAX: (514) 856-6886e-mail: [email protected] For immediate technical or app...

Page 3 - Unpacking Instructions; Notes
Page 4 - Accessories; . We can also be reached on the; Description; Hard Carrying Case, Standard; NOTE

Unpacking Instructions Remove the Packing List and verify that you have received allequipment, including the following (quantities in parentheses):• OS530/OS520 Series Handheld Infrared Thermometer (1)• AA Size Lithium Batteries (4)• Soft Cover Carrying Case (1)• Analog Cable (1)• RS232 Cable (only ...

Other Omega Models

All Omega Other