Page 2 - One Omega Drive, River Bend Technology Centre; OMEGAnet
Servicing North America: U.S.A.: One Omega Drive, P.O. Box 4047 ISO 9001 Certified Stamford, CT 06907-0047TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: [email protected] Canada: 976 BergarLaval (Quebec) H7L 5A1, CanadaTEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: [email protected] For immediate technic...
Page 3 - RETURN REQUESTS/INQUIRIES; WARRANTY
WARRANTY/ DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for aperiod of 25 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal two (2) year product warranty to cover handling and shipping...
Page 4 - TABLE OF CONTENTS; OS1592 Infrared Fiber Optic Thermometer/Transmitter
TABLE OF CONTENTS SECTION ..................................................................PAGE Section 1 Introduction ........................................................................ 1 Section 2 Installation ........................................................................... 1 2.1 ...
Page 5 - TABLE OF FIGURES
TABLE OF FIGURES FIGURE ..................................................................PAGE 1 OS1592 Main Unit ............................................................................ 3 2 Power Supply and Analog Output Connections ........................... 3 3 Visual Functional Flow Chart ....
Page 6 - event reshipment is necessary.
INTRODUCTION The new OS1592 series Infrared Fiber Optic Thermometer/Transmitterprovides non-contact temperature measurement for industrialapplications. The unit measures temperature starting at 260°C (500°F)and up to 2482°C (4500°F). It provides dual analog outputs (4-20 mA, 0-5VDC, 0-10 VDC, 1 mV/D...
Page 7 - Temperature Range; Accessories
The following describes the ordering information: The unit provides two separate analog outputs. The first is 1mV/Deg(Standard). The second analog output to be specified as follows : - * , where, - mA , 4-20 mA output - V1, 0/5 VDC output - V2, 0/10 VDC output - K, Thermocouple output, K type (For R...
Page 8 - – Electrical Connection; Figure 2 - Power Supply and Analog Output Connections
2.2 – Electrical Connection Attach the optical assembly to the optical adapter located on the side ofthe housing. Refer to Fig. 1 for the overall appearance of the unit. Open the cover of the aluminum housing. Slide your cable through themetal feed thru and connect the wires to the 9 position termin...
Page 9 - OPERATION; Table 1 - Functional Flow Chart; DISPLAY MODES
OPERATION Table 1 shows all the display modes of the model OS1592, as well as allthe functions of the membrane keypad. Fig 3 shows the Visual Functionalflow chart of the display. Table 1 - Functional Flow Chart Figure 3 - Visual Functional Flow Chart OS1592 Infrared Fiber Optic Thermometer/Transmitt...
Page 10 - change these settings.
The Emissivity setting as well as the temperature Engineering unit (°F or °C) are stored in the non-volatile memory. Removing the main power will not erase or change these settings. 3.1 - Changing the Temperature from °F to °C (or vice versa) Press the key to go to either the MAX , MIN, or DIF displ...
Page 13 - MODEL
Figure 9 - Polymer Bolt Assembly (L3) with 90° Angle Air Purge Fitting Figure 10 - Optical Head, Mounting Bracket OS1592-MB Figure 11 - Air Purge Collar OS1592 Infrared Fiber Optic Thermometer/Transmitter 3 8 FIBER 72 (2.84) 53 ± 1.5 (2.10 ± 0.06) 12.7 ± 1.5 (.50 ± 0.06) 11 (0.438) 102 ± 1.5 4.00 ± ...
Page 14 - SPECIFICATIONS; Optical Assemblies
SPECIFICATIONS Temperature Range R1 260 to 538°C (500 to 1000°F) R2 538 to 1093°C (1000 to 2000°F) R3 1093 to 2482°C (2000 to 4500°F) Accuracy at 22°C (72 °F) 1% of Rdg. ambient temperatureand at Emissivity of 0.95 or greater Repeatability 0.5% of Rdg Resolution 1°C or 1°F Response Time 25 msec (0 t...
Page 15 - Analog Outputs
Display Backlit LCD dual display Keypad switch 4 position, tactile feed back membrane Electrical Isolation Between Input supply and Analog outputs, 1000 VAC Calculated Temperature Maximum (MAX), Minimum (MIN) values and Differential (DIF), Reset via keypad High Alarm LED & Display Icon indicatio...
Page 16 - MAINTENANCE
OS1592 Infrared Fiber Optic Thermometer/Transmitter 5 11 MAINTENANCE Routine maintenance is not required except for periodic re-calibration,occasional inspection of the input and output ends of the fiber assemblyfor cleanliness, and a check for broken fibers if damage is suspected. The optical fiber...
Page 17 - Safety Warnings and IEC Symbols; IEC Symbol; Caution and Safety Information; protection provided by the equipment may be impaired.
OS1592 Infrared Fiber Optic Thermometer/Transmitter Addendum 12 Safety Warnings and IEC Symbols This device is marked with international safety and hazardous symbols inaccordance with IEC1010. It is important to read and follow all the precautionsand instructions in this manual before operating or c...
Page 18 - Shop online at omega.com
M3672/0905 Where Do I Find Everything I Need for Process Measurement and Control? OMEGA…Of Course! Shop online at omega.com TEMPERATURE 䡺 ⻬ Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies 䡺 ⻬ Wire: Thermocouple, RTD & Thermistor 䡺 ⻬ Calibrators & Ice Point Refe...