Omega LV800 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
1
2
3
4
5
6
7
8
9
10
11
12
Table of Contents:
Page 2 – One Omega Drive, River Bend Technology Centre; OMEGAnet
Page 3 – L V 8 0 0 S E R I E S
Page 4 – P R E - I N S T A L L A T I O N C O N S I D E R A T I O N S; Choosing a Location:; - When selecting a location for the LV800,
Page 5 – M E C H A N I C A L I N S T A L L A T I O N; Standard, Food Grade and Stub Probe Mounting:; Weld fitting or attach mounting plate to vessel wall.; Permanently Connected Equipment:; E L E C T R I C A L I N S T A L L A T I O N
Page 6 – Output Relay Contacts:; C A L I B R A T I O N; Permit the application material to cover the probe.; While
Page 7 – - Its status indicates “no material sensed” con-
Page 8 – Verify power is applied to the sensor.; when material is absent
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Page 2 - One Omega Drive, River Bend Technology Centre; OMEGAnet
Servicing North America: U.S.A.: One Omega Drive, P.O. Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: [email protected] Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: [email protected] For immediate tech...
Page 3 - L V 8 0 0 S E R I E S
This manual contains the information necessary to ensure a safe andsuccessful installation. Please read and comply with the section on page9 of this manual pertaining to SAFETY. Doing so will ensure proper oper-ation of the equipment and the safety of all personnel. Before discarding shipping contai...
Page 4 - P R E - I N S T A L L A T I O N C O N S I D E R A T I O N S; Choosing a Location:; - When selecting a location for the LV800,
P R E - I N S T A L L A T I O N C O N S I D E R A T I O N S 3 Choosing a Location: (See Figure 2) 1) Material Flow - When selecting a location for the LV800, choose a point in the vessel where the probe will be out of the direct flow of incoming and outgoing material to preventany mechanical damage ...
Page 5 - M E C H A N I C A L I N S T A L L A T I O N; Standard, Food Grade and Stub Probe Mounting:; Weld fitting or attach mounting plate to vessel wall.; Permanently Connected Equipment:; E L E C T R I C A L I N S T A L L A T I O N
4 M E C H A N I C A L I N S T A L L A T I O N Standard, Food Grade and Stub Probe Mounting: (See Figures 3 & 4) 1) Select a mounting location in accordance with the Pre-Installation Recommendations. 2) If using a welded fitting, cut a hole into the side/top of the vessel corresponding to the mou...
Page 6 - Output Relay Contacts:; C A L I B R A T I O N; Permit the application material to cover the probe.; While
5 Figure 5 Power Input: (See Figure5) The LV800 is designed to accept either 115VAC or 230VAC(factory set). Verify the intended voltage supply is compatiblewith the voltage configuration indicated on the electronics andthe external nameplate. Connect power as shown in Figure 5.Select wire size that ...
Page 7 - - Its status indicates “no material sensed” con-
6 Delay: A potentiometer is provided for setting the time delay betweenthe time material is "sensed" (Yellow LED on) and the time therelay contact output changes (Red LED on). Units have a 1-turn potentiometer. A clockwise rotation will increase the delayfrom .25 to 15 seconds. This adjustme...
Page 8 - Verify power is applied to the sensor.; when material is absent
T R O U B L E S H O O T I N G M A I N T E N A N C E PROBLEM: Sensor will not sense materialCAUSE/SOLUTION:1) Verify power is applied to the sensor. 2) Verify "Sense Adjust." Reposition adjustment clockwise therefore making the probe more sensitive to "difficult to sense" materials. 3...
Page 9 - M E C H A N I C A L S
8 M E C H A N I C A L S Standard Probe Stub Probe DIMENSIONS ARE SHOWN IN INCHES WITH MILLIMETER EQUIVALENT IN BRACKETS
Page 11 - RETURN REQUESTS/INQUIRIES; WARRANTY
WARRANTY/ DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for aperiod of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping...
Page 12 - Shop online at omega.com
M-4168/0405 Where Do I Find Everything I Need for Process Measurement and Control? OMEGA…Of Course! Shop online at omega.com TEMPERATURE M U Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies M U Wire: Thermocouple, RTD & Thermistor M U Calibrators & Ice Point Ref...