Omega HHLM-1MV - Manual

Omega HHLM-1MV

Omega HHLM-1MV – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
Page: / 13

Table of Contents:

  • Page 3 – using the lightmeter.; WARNING; • To avoid electric shock, do not operate this product in wet or damp
  • Page 4 – SPECIFICATIONS; GENERAL; drops below the operating level.
  • Page 5 – ELECTRICAL; Photometric Formulas:; of the average human eye
  • Page 6 – OPERATING INSTRUCTIONS; CIE standard illuminant A can be realised by means of CIE standard
  • Page 7 – OPERATION; ground input jack on the DMM. Observe polarity.
  • Page 8 – SPECIAL CONSIDERATIONS; be cleaned with a soft cloth and isopropyl alcohol.; • Cosine Law; is the angle between the normal to the
  • Page 9 – Luminous Efficiency Coefficient
  • Page 11 – WARRANTY
  • Page 12 – RETURN REQUESTS / INQUIRIES
  • Page 13 – HEATERS
Loading the manual

OMEGA

HHLM-1MV

Light Transducer

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - using the lightmeter.; WARNING; • To avoid electric shock, do not operate this product in wet or damp

INTRODUCTION This instrument is a portable easy use, compact-sized light transducer designed for simple one hand operation. Provides lux unit measurements. SAFETY INFORMATION It is recommended that you read the safety and operation instructions before using the lightmeter. WARNING • To avoid electri...

Page 4 - SPECIFICATIONS; GENERAL; drops below the operating level.

2 SPECIFICATIONS GENERAL Low battery indication: the "Red LED" is displayed when the battery voltage drops below the operating level. Operating Environment: 0°C to 50°C at < 70% relative humidity.Storage Temperature: -20°C to 60°C, 0 to 80% R.H. with battery removed from meter. Accuracy: ...

Page 5 - ELECTRICAL; Photometric Formulas:; of the average human eye

3 ELECTRICAL Photometric Formulas: 10.764·footcandles=lux (lumens/meter 2 ) 0.0929·lux=footcandles (lumens/foot 2 ) Rangescale: DMM to 200.0mV range ¸ 10(20lux), x1(200lux) x10(2000lux), x100(20000lux)x1000(200000lux) Resolution: 0.01luxSpectral response: CIE photopic Acceptance angle: ¦ ¢ 2 <2% ...