Nutone LS100L - Manual

Nutone LS100L

Nutone LS100L – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
Page: / 10

Table of Contents:

  • Page 2 – FIGURE 3
  • Page 3 – One Year Limited Warranty; FIGURE 4; GRILLE/LIGHT INSTALLATION; LAMP REPLACEMENT
  • Page 4 – AVERTISSEMENT: POUR RÉDUIRE LES RISQUES; A. Utiliser cet appareil seulement pour les fins prévuespar le; DIRECTIVES D' INSTALLATION; AVERTISSEMENT: POUR RÉDUIRE LES RISQUES D’INCENDIE, DE; électriques et les autres canalisations.; Ventilateur Ultra-QuieTTest; FIGURE 1; FIGURE 2
  • Page 5 – POUR OBTENIR LES MEILLEURS RÉSULTATS; PREPARATION; MONTAGE DU BOÎTIER
  • Page 6 – Garantie limitée d’un an; GRILLE/INSTALLATION DE L’ÉCLAIRAGE; REMPLACEMENT DE L’AMPOULE
  • Page 7 – PREPARACION; Ventilador Ultra-QuieTTest; FIGURA 1; FIGURA 2
  • Page 8 – FIGURA 3
  • Page 9 – Garantía Limitada de un Año; FIGURA 4; PARA CAMBIAR LA BOMBILLA
  • Page 10 – PARTS LIST
Loading the manual

IMPORTANT SAFETY INSTRUCTIONS

WARNING: TO REDUCE THE RISK OF FIRE. ELECTRIC SHOCK,

OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

A. Use this unit only in the manner intended by the manufacturer.

If you have questions, contact the manufacturer.

B. Before servicing or cleaning unit, switch power off at service

panel and lock service panel to prevent power from being
switched on accidentally.
When the service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the service panel.

CAUTION:

For general ventilating use only. Do not use to exhaust hazardous

or explosive materials and vapors.

INSTALLATION INSTRUCTIONS

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,

OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

A. Installation work and electrical wiring must be done by qualified

person(s) in accordance with all applicable codes and standards, including fire-rated
construction.

B. Sufficient air is needed for proper combustion and exhausting of gases through the

flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating
equipment manufacturer's guideline and safety standards such as those published by
the National Fire Protection Association (NFPA),and the American Society for
Heating, Refrigeration and Air Conditioning Engineers (ASHRAE),
and the local code authorities.

C. When cutting or drilling into wall or ceiling, do not damage electrical wiring

and other hidden utilities.

D. Ducted fans must always be vented to the outdoors.
E. If this unit is to be installed over a tub or shower, it must be marked as appropriate for

the application and be connected to a GFCI (Ground Fault Circuit Interrupter)
protected branch circuit.

F.

NEVER

place a switch where it can be reached from a tub or shower.

Do not install in a ceiling insulated to a value greater than R40.

Suitable for use with solid state speed controls. Use NuTone Model VS-64.

Not for use in kitchens.

FOR BEST RESULTS

When installing the Ventilator in a

new construction site,

install housing during

the rough-in construction of the building. The blower unit and grille should be installed
after the finished ceiling is in place.

To install a ventilator in an

existing building

requires an accessible area (attic or

crawl space) above the planned location.

INSTALLATION IN A NEW CONSTRUCTION SITE

PREPARATION

1. Remove blower/power unit assembly from housing:

A. If necessary, unplug power unit.
B. Loosen one (1) mounting screw.
C. Slide unit back to free it from the mounting screw.
D. Remove unit and set aside until needed.

2. Remove wiring knockouts from housing, as needed.

INSTALLATION INSTRUCTIONS

READ & SAVE THESE INSTRUCTIONS!

Ultra-QuieTTest Fan/Lights

MODELS: LS80L, LS100L

SUITABLE FOR USE OVER TUB OR SHOWER ENCLOSURE
WHEN INSTALLED IN A GFCI PROTECTED BRANCH CIRCUIT.

FIGURE 1

ROOF CAP

4" DIAMETER DUCT

90° ELBOW

WALL CAP

FIGURE 2

GROUND

SCREW

120v AC SUPPLY

WHITE (NEUTRAL)

SWITCH BOX

CEILING INSTALLATION

FAN

RECEPTACLE

LAMP

RECEPTACLE

(3 PIN)

BLACK (HOT)

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - FIGURE 3

MOUNTING THE HOUSING 1. Refer to Figure 3. Insert mounting brackets at each end of housing. 2. Place long side of housing parallel to ceiling joist. Position housing in desired location. Make sure housing flange is even with theplanned finished ceiling. 3. Use screws or nails (not provided) to secur...

Page 3 - One Year Limited Warranty; FIGURE 4; GRILLE/LIGHT INSTALLATION; LAMP REPLACEMENT

Product specifications subject to change without notice. 4820 Red Bank Road, Cincinnati, Ohio 45227 Printed in U.S.A., Rev. 05/2001, Part No. 88950 One Year Limited Warranty WARRANTY OWNER: NuTone warrants to the original consumer purchaser of its products that such products will be free from defect...

Page 4 - AVERTISSEMENT: POUR RÉDUIRE LES RISQUES; A. Utiliser cet appareil seulement pour les fins prévuespar le; DIRECTIVES D' INSTALLATION; AVERTISSEMENT: POUR RÉDUIRE LES RISQUES D’INCENDIE, DE; électriques et les autres canalisations.; Ventilateur Ultra-QuieTTest; FIGURE 1; FIGURE 2

INSTRUCTIONS D'INSTALLATION LIRE ET CONSERVER CES INSTRUCTIONS Le ventilateur comprend un boîtier, des supports de montage, un couvercle de boîte de jonction, un ensemble moteur/ventilateur (moteur,roue, plaque de montage) et une grille. • Pour utilisation avec les commandes de vitesse électroniques...

Other Nutone Models