Nutone 768CHNT - Manual
Nutone 768CHNT – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – INSTALL THE HOUSING; New Construction
- Page 3 – INSTALL THE DUCTWORK; CONNECT THE WIRING; Existing Construction
- Page 4 – BULB REPLACEMENT; SERVICE PARTS
- Page 5 – VEUILLEZ LIRE CES DIRECTIVES ET LES CONSERVER; AVERTISSEMENT; ATTENTION; Voir le mode d’utilisation et d’entretien; PLANIFICATION DE LA POSE
- Page 6 – INSTALLATION DU BOÎTIER; Construction neuve
- Page 7 – FIXATION DE LA PLAQUE DE PROTECTION; POSE DU CONDUIT; RACCORD DU CÂBLAGE; Bâtisse déjà construite
- Page 8 – REMPLACEMENT DES AMPOULES; PIÈCES DE RECHANGE; GARANTIE
- Page 9 – Página 9; VENTILADOR DECORATIVA; ADVERTENCIA; PRECAUCIÓN; LEA Y CONSERVE ESTAS INSTRUCCIONES; INSTALACIONES TÍPICAS; PLANIFICACIÓN DE LA INSTALACIÓN
- Page 10 – INSTALACIÓN DE LA CUBIERTA; Construcción nueva
- Page 11 – CONEXIÓN ELÉCTRICA; Construcción existente; ARME EL TACHO DE REJILLA
- Page 12 – USO Y CUIDADO; REEMPLAZO DEL FOCO; PIEZAS DE REPUESTO; GARANTIA
Page 1
MODEL 768CHNT
DECORATIVE
VENTILATION FAN WITH LIGHT
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufac-
turer. If you have questions, contact the manufacturer at
the address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at
service panel and lock the service disconnecting means
to prevent power from being switched on accidentally.
When the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as a
tag, to the service panel.
3. Installation work and electrical wiring must be done by
a qualified person(s) in accordance with all applicable
codes and standards, including fire-rated construction
codes and standards.
4. Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel
burning equipment to prevent backdrafting. Follow the
heating equipment manufacturer’s guideline and safety
standards such as those published by the National Fire
Protection Association (NFPA), and the American Society
for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not dam-
age electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. NEVER place a switch where it can be reached from a
tub or shower.
8. This unit must be grounded.
9. This unit is U.L. listed. Type I.C. inherently protected.
CAUTION
!
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2. This product is designed for installation in FLAT CEILINGS
ONLY. Do not mount this product in a wall.
3. The light fixture assembly must be mounted to the fan
housing assembly included with this product. Do not
mount the light fixture assembly to a wiring outlet box.
4. To avoid motor bearing damage and noisy and/or unbal-
anced impellers, keep drywall spray, construction dust,
etc. off power unit.
5. Please read specification label on product for further
information and requirements.
TYPICAL INSTALLATIONS
HOUSING MOUNTED
DIRECTLY TO JOIST
2x6 (or larger)
Discharge parallel to joists.
HOUSING
2 x 4
CEILING
JOIST or
TRUSS
MOUNTING
TABS
POWER CABLE
ADDITIONAL
FRAMING
2 x 4
CEILING
JOIST or
TRUSS
CEILING
MATERIAL
GRILLE
PAN
GLASS
LIGHT SHADE
HOUSING MOUNTED
TO 2x4 TRUSS
Requires additional framing
for mounting tabs.
Discharge parallel to joists.
HOUSING MOUNTED
TO “I” JOIST
Requires additional framing
for mounting tabs.
Discharge parallel to joists.
Installer:
Leave this manual with the
homeowner.
Homeowner:
Use and Care information on page 4.
*
Additional framing must be a 2x6 (minimum height), at least 9-inches long.
*
*
SUSPENDED CEILINGS
Housing hung with wires -
3-point mount.
PLAN THE INSTALLATION
The unit will operate
most quietly and
efficiently when
located where the
shortest possible
duct run and
minimum number
of elbows will be
needed.
Use a roof cap or
wall cap that has a
built-in damper to
reduce backdrafts.
Plan to supply the
unit with proper
line voltage and
appropriate power
cable.
ROOF
CAP
*
4-IN. ROUND
ELBOW(S)
*
4-IN.
ROUND
DUCT
*
WALL CAP
*
*
Purchase
separately
INSULATION
(Can be placed
around and over
fan housing.)
FAN
HOUSING
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Page 2 MODEL 768CHNT 3. Set housing aside and drive nails partially into joist at the top of both keyhole marks. 4. Hang housing from nails and pound nails tight. To ensure a noise-free mount, pound another nail through the top hole of each mounting tab. INSTALL THE HOUSING (continued) New Construct...
Page 3 MODEL 768CHNT FINIAL NUT GLASS SHADE GRILLE PAN ROD WASHER 60 WATT MAX. B10 BASE CANDELABRA BULBS (2 REQ.) STEEL WASHER FELTWASHER(Add secondwasher asneeded tosecure shadetightly.) FELT WASHER B L K V E N TS W I T C H B L U B L K W H T W H T W H T L I G H T ( W H I T E ) G R D V E N T ( B L A...
Page 4 MODEL 768CHNT USE AND CARE USE AND CARE WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND LOCK OUT SERVICE PANEL BEFORE CLEANING OR SERVICING THIS UNIT. BULB REPLACEMENT Remove glass shade. Replace bulbs as required. Replace glass shade.Use 60-watt (maximum), B10 type, candelabra bulbs. MOTOR L...