Msd 6012 GM LS2_7 Ignition Control, 06-On 58-Tooth Cra- User Manual

Msd 6012 GM LS2_7 Ignition Control, 06-On 58-Tooth Cra

Msd 6012 GM LS2_7 Ignition Control, 06-On 58-Tooth Cra– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
Page: / 8

Table of Contents:

  • Page 3 – Figure 1 Wiring the MSD 6LS-2 Controller.
  • Page 4 – Insert the installation CD into your PC.; Saves and Transfers; are two ways to save your files.
  • Page 5 – PROGRAMMABLE FEATURES; Retard if activated.; MAP SENSOR SELECT; and 12580698 are 2-bar sensors that connect to the MSD harness.; TIMING LIMIT; with a default of 5°.
  • Page 6 – REV LIMITS; RevMax; STEP RETARD; LS 1 Select when using factory style LS 1 or MSD; TIMING CURVE MODULES; Note: Any updates that are made using the PC software will; Figure 3 Timing Curve Modules.
  • Page 7 – TECH NOTES
  • Page 8 – M S D I G N I T I O N; Limited Warranty; for special or consequential damages.; Service; warranty. When returning MSD components for warranty service,; Proof of Purchase must be supplied for; All returns must have a Return Material Authorization (RMA) number; issued to them before
Loading the manual

Parts Included

1 – Ignition Controller, PN 6012

1 – Pro-Data+ Software CD

1 – Harness

1 – Parts Bag

6 – Timing Modules

MSD 6LS-2 Ignition Controller for

Carbureted and EFI LS 2/LS 7 Engines

PN 6012

Optional Accessories

Hand Held Monitor, PN 7550

Factory EFI Harness, PN 88862

WARNING: During installation, disconnect the battery cables. When Disconnecting, always remove

the Negative cable first and install it last.

Note: Solid core spark plug wires or non-resistor spark plugs cannot be used with an MSD Ignition

Control.

CARBURETOR

The PN 6012 Ignition Controller is designed for GM LS 2/LS 7 based engines that have been retro-fit with

an intake manifold and carburetor. The Controller is supplied with a wiring harness that connects to the

factory connectors for a simple installation.

EFI

This Controller can also be used in stock, EFI applications, by using accessory Harness PN 88862. This

Harness allows the PN 6012 Controller to tap into the sensor signals without interrupting the OEM ECU.

The ECU and Fuel Injectors operate as normal while the PN 6012 controls the ignition and timing.

OPERATION

The MSD Controller offers several programmable features that allow rpm and timing adjustments. This can

be achieved through the supplied Pro-Data+ software via a PC or with the optional Hand Held Programmer,

PN 7550. Timing adjustments and selections can also be made with plug-in modules. Software installation,

operation and the programmable features of the Controller are explained in detail in this document. More

information can be found in the Pro-Data+ Software Help section.

MOUNTING

The Controller is designed to be mounted under the hood or on the firewall. Do not mount the unit near

exhaust. Four vibration mounts are supplied to mount the unit. Find a suitable location, confirm that all of

the wires reach their connections. Mark the mounting hole locations using the unit. Drill the holes with a

3/16" bit.

WIRING

All of the wiring, except three wires, are routed into factory style connectors to ensure an easy installation.

The wire descriptions follow in the chart on pages 2 and 3.

M S D I G N I T I O N

• W W W . M S D I G N I T I O N . C O M • ( 9 1 5 ) 8 5 7 - 5 2 0 0 • F A X ( 9 1 5 ) 8 5 7 - 3 3 4 4

ONLINE PRODUCT REGISTRATION: Register your MSD product online and you’ll be entered

in our monthly 8.5mm Super Conductor Spark Plug Wire give-away! Registering your product

will help if there is ever a warranty issue with your product and helps the MSD R&D team create

new products that you ask for! Go to www.msdignition.com/registration.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - Figure 1 Wiring the MSD 6LS-2 Controller.

INSTALLATION INSTRUCTIONS 3 M S D I G N I T I O N • W W W . M S D I G N I T I O N . C O M • ( 9 1 5 ) 8 5 7 - 5 2 0 0 • F A X ( 9 1 5 ) 8 5 7 - 3 3 4 4 2-PIN CONNECTOR, ACCESSORIES PINK Pin-B Step Retard. When 12-volts are supplied, the Step Retard is activated. BLUE Pin-A Two-Step. When 12-volts ar...

Page 4 - Insert the installation CD into your PC.; Saves and Transfers; are two ways to save your files.

4 INSTALLATION INSTRUCTIONS M S D I G N I T I O N • W W W . M S D I G N I T I O N . C O M • ( 9 1 5 ) 8 5 7 - 5 2 0 0 • F A X ( 9 1 5 ) 8 5 7 - 3 3 4 4 PRO-DATA+ Installation of the Pro-Data+ Software 1. Insert the installation CD into your PC. 2. In Windows, click on Start then select Run. 3. In th...

Page 5 - PROGRAMMABLE FEATURES; Retard if activated.; MAP SENSOR SELECT; and 12580698 are 2-bar sensors that connect to the MSD harness.; TIMING LIMIT; with a default of 5°.

INSTALLATION INSTRUCTIONS 5 M S D I G N I T I O N • W W W . M S D I G N I T I O N . C O M • ( 9 1 5 ) 8 5 7 - 5 2 0 0 • F A X ( 9 1 5 ) 8 5 7 - 3 3 4 4 PROGRAMMABLE FEATURES The following explains the programmable features of the PN 6012 Controller. The features are listed in the same order shown on...

Other Msd Models

All Msd Other