Page 2 - Always “On” UPS Systems Inc.
Page 3 - SAVE THESE INSTRUCTIONS
Always “On” UPS Systems Inc. 3 SAVE THESE INSTRUCTIONS This manual contains important instructions for the GES-801L, GES-102L, GES-152L, GES-202L, GES-302L and should be followed during installation and maintenance of the UPS and batteries. The UPS contains voltages that are potentially hazardous. P...
Page 5 - Introduction
Always “On” UPS Systems Inc. 5 Introduction The L-Series is a Line Interactive UPS system that includes the newest and latest technology enhancements. The Line Interactive technology with AVR function (on-line voltage boost-up & buck-down) allows for a wide input voltage range of 90 to 150VAC. T...
Page 6 - Safety Instructions
Always “On” UPS Systems Inc. 6 Safety Instructions The UPS has its own internal energy source (batteries), therefore the output receptacles may have electricity present even though the UPS is disconnected from the utility power. The DC voltage provided from the internal batteries are as follows: a) ...
Page 7 - Presentation
Always “On” UPS Systems Inc. 7 Presentation Front Panel 1. POWER bar graph (BATTERY CHARGE/LINE VOLTAGE) This displays the present battery charge as a percentage of battery capacity. It also displays the utility line voltage. 2. LOAD bar graph This displays the amount of power required by the load a...
Page 8 - OUTPUT POWER RECEPTACLES
Always “On” UPS Systems Inc. 8 Rear Panel 11. TELEPHONE/MODEM/ETHERNET SURGE PROTECTION Surge protection for telephone line, modem line, and 10BaseT line to maintain a completely safe connection for INTERNET/INTRANET service. 12. EXTERNAL BATTERY PACK CONNECTOR (optional) Allows for extended runtime...
Page 9 - INPUT CIRCUIT BREAKER; COMPUTER INTERFACE
Always “On” UPS Systems Inc. 9 16. INPUT CIRCUIT BREAKER It trips when the connected loads exceed the protected receptacle's capacity. The center plungers of the circuit breakers extend when tripped. 17. SITE WIRING FAULT INDICATORS (RED LED) It illuminates when the UPS is connected to an improperly...
Page 10 - Installation
Always “On” UPS Systems Inc. 10 Installation Unpacking and Inspection Examine the packaging for damage. Inform the carrier immediately if and/or when damage is noticed. Retain the packaging for future use. Placement Install the UPS in a protected area with adequate airflow and free of excessive dust...
Page 12 - Operation
Always “On” UPS Systems Inc. 12 Operation Switching “On” the UPS With the UPS plugged in, press and hold the “ON/TEST” button for at least 1 second to switch the UPS on. The UPS will perform a self-test each time it is switched on. Note : When switched off, and still plugged into utility, the UPS ma...
Page 13 - Audible Alarm
Always “On” UPS Systems Inc. 13 Battery Charge Bar Graph This 5 LED display indicates the present charge of the UPS's batteries as a percentage of the total battery capacity. When all five LED’s are lit, the batteries are fully charged. When only two of the LED’s are lit, the batteries can supply le...
Page 14 - Software Options
Always “On” UPS Systems Inc. 14 Software Options UPSilon 2000 Software The UPSilon 2000 software utilizes standard RS-232 interface to perform monitoring functions, and provides an orderly shutdown of a computer system in the event of power failure. Moreover, UPSilon 2000 displays all the diagnostic...
Page 15 - Open Collector (Dry Contact) Communication
Always “On” UPS Systems Inc. 15 Computer Interface Port The computer interface port has the following characteristics: The communication port on the back of the UPS may be connected to a host computer. This port allows the computer to monitor the status of the UPS and control the operation of the UP...
Page 16 - Battery Replacement; Be careful not to touch any inner components when
Always “On” UPS Systems Inc. 16 Battery Replacement Your batteries should run anywhere from 3-5 years before they need to be replaced. Please follow the instructions below for easy, trouble free, battery replacement. 1. Turn the UPS off (follow procedure previously mentioned) 2. Unplug the UPS from ...
Page 17 - Troubleshooting; Problems Possible
Always “On” UPS Systems Inc. 17 Troubleshooting Please follow the guidelines below for solutions to common problems: Check UPS input plug and wiring. Check UPS input voltage. Please prepare the information as follows for service personnel: UPS model number and serial number Description of problem(s)...
Page 18 - Storage
Always “On” UPS Systems Inc. 18 Storage Storage Conditions Store the UPS covered and upright in a cool, dry location, with its battery fully charged. Before storing, charge the UPS for at least eight (8) hours. Remove any accessories from the accessory slot and disconnect any cables connected to the...
Page 19 - Battery Bank Installation; BLACK
Always “On” UPS Systems Inc. 19 Battery Bank Installation Install up to 8 battery banks per L Series UPS following the instructions below. Caution: Make sure the UPS is shutdown and unplugged before connecting additional Battery Packs (refer to Switching the UPS “Off” section, page 11) 1. Locate the...
Page 20 - Specifications; Specification
Always “On” UPS Systems Inc. 20 Specifications Specification Comparison MODEL NO. GES-801L GES-102L GES-152L GES-202L GES-302L MAXIMUM CAPACITY 800VA / 560W 1kVA / 700W 1.5kVA / 1050W 2kVA / 1400W 3kVA / 2100W GENERAL UPC ORDER CODE 825433 22100 825433 22200 825433 22300 825433 22400 825433 22500 NO...